Flexible pressure sensors via engineering microstructures for wearable human-machine interaction and health monitoring applications
Open accessThe DOI matches its Crossref record; 120 of the 120 references it cites were found in a registry or an index.
Abstract
Flexible pressure sensors capable of transducing pressure stimuli into electrical signals have drawn extensive attention owing to their potential applications for human-machine interaction and healthcare monitoring.To meet these application demands, engineering microstructures in the pressure sensors are an efficient way to improve key sensing performances, such as sensitivity, linear sensing range, response time, hysteresis, and durability.In this review, we provide an overview of the recent advances in the fabrication and application of high-performance flexible pressure sensors via engineering microstructures.The implementation mechanisms and fabrication strategies of microstructures including micropatterned, porous, fiber-network, and multiple microstructures are systematically summarized.The applications of flexible pressure sensors with microstructures in the fields of wearable human-machine interaction, and ex vivo and in vivo healthcare monitoring are comprehensively discussed.Finally, the outlook and challenges in the future improvement of flexible pressure sensors toward practical applications are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Choong, C., Shim, M., Lee, B., Jeon, S., Ko, D., Kang, T., Bae, J., Lee, S. H., Byun, K., Im, J., et al. (2014) · Advanced Materials · doi:10.1002/adma.201305182 · Cited by 1,252 · cited 3×
“The shapes for micropatterned structures include both irregular shapes and regular shapes such as pillars, pyramids, and domes (Chen et al., 2019b; Choong et al., 2014; Tang et al., 2019).”
BackgroundMethodWearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, J., Kim, M., Lee, M.-S., Kim, K., Ji, S., Kim, Y.-T., Park, J., Na, K., Bae, K.-H., Kyun Kim, H., et al. (2017) · Nature Communications · doi:10.1038/ncomms14997 · Cited by 951 · cited 3×
“Kim et al. developed a transparent contact lens sensor by placing two inductive spirals made of graphene-AgNW hybrid electrodes on both sides of a silicone elastomer film (Kim et al., 2017).”
BackgroundInfluentialPeng, X., Dong, K., Ye, C., Jiang, Y., Zhai, S., Cheng, R., Liu, D., Gao, X., Wang, J., & Wang, Z. L. (2020) · Science Advances · doi:10.1126/sciadv.aba9624 · Cited by 885 · cited 1×
“…3.8 3 105 0.000025–100 0.016 8,000 (Lee et al., 2021b) Graphene/PVDF 25.9 0.01–1400 3.5 10,000 (Kong et al., 2020) PDMS/MXene 151.4 0.0044–15 130 10,000 (Cheng et al., 2020) rGO/PDMS 55 0.004–400 30 9,000 (Zhang et al., 2019b) Electrodes: PDMS/PPy ITO Dielectric layer: Ionic gel 26.6 0.644–26.6…”
InfluentialBai, N., Wang, L., Wang, Q., Deng, J., Wang, Y., Lu, P., Huang, J., Li, G., Zhang, Y., Yang, J., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-14054-9 · Cited by 810 · cited 2×
“reported a bioresorbable, wireless pressure sensor based on passive inductor-capacitor resonance circuits in layouts with optimal sensitivity of 200 kHz/mmHg and resolution of 1 mmHg (Lu et al., 2020).”
BackgroundWearable Sensors‐Enabled Human–Machine Interaction Systems: From Design to Application
Yin, R., Wang, D., Zhao, S., Lou, Z., & Shen, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008936 · Cited by 769
Guo, Y., Zhong, M., Fang, Z., Wan, P., & Yu, G. (2019) · Nano Letters · doi:10.1021/acs.nanolett.8b04514 · Cited by 741 · cited 2×
“Recently, the flexible pressure sensors with fibernetwork microstructures have attracted considerable attention from academia and industry (Guo et al., 2019; Han et al., 2019a; Peng et al., 2020).”
BackgroundInfluentialBae, G. Y., Pak, S. W., Kim, D., Lee, G., Kim, D. H., Chung, Y., & Cho, K. (2016) · Advanced Materials · doi:10.1002/adma.201600408 · Cited by 646
Nanomesh pressure sensor for monitoring finger manipulation without sensory interference
Lee, S., Franklin, S., Hassani, F. A., Yokota, T., Nayeem, M. O. G., Wang, Y., Leib, R., Cheng, G., Franklin, D. W., & Someya, T. (2020) · Science · doi:10.1126/science.abc9735 · Cited by 640
Pyo, S., Lee, J., Bae, K., Sim, S., & Kim, J. (2021) · Advanced Materials · doi:10.1002/adma.202005902 · Cited by 631 · cited 3×
“For example, human-machine interaction technology allows people to communicate or control machines via tactile sensation (Pyo et al., 2021).”
BackgroundInfluentialLiu, H., Chen, X., Zheng, Y., Zhang, D., Zhao, Y., Wang, C., Pan, C., Liu, C., & Shen, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202008006 · Cited by 625 · cited 10×
“…with an outstanding sensing capacity up to 90% strain (corresponding 85.21 kPa), ultralow detection limit of 0.5% strain (corresponding 0.01 kPa), robust fatigue resistance over 1000 cycles, excellent piezoresistive stability, and reproductivity in extremely harsh environments (Liu et al., 2021).”
BackgroundInfluential
Cited by
Lv, C., Tian, C., Jiang, J., Dang, Y., Liu, Y., Duan, X., Li, Q., Chen, X., & Xie, M. (2023) · Advanced Science · doi:10.1002/advs.202206807 · Cited by 232
A review on flexible wearables – Recent developments in non-invasive continuous health monitoring
Kazanskiy, N. L., Khonina, S. N., & Butt, M. A. (2024) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2023.114993 · Cited by 196
Metadata
- Authors
- Cui, X., Huang, F., Zhang, X., Song, P., Zheng, H., Chevali, V., Wang, H., & Xu, Z.
- Venue
- iScience
- Publisher
- Elsevier BV
- Published
- 2022-04
- Volume
- 25
- Issue
- 4
- Pages
- 104148
- ISSN
- 2589-0042 (ISSN-L)
- OpenAlex
- W4223602437
- Cited by
- 170
- References
- 120
- FWCI
- 9.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.