Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 219

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Left atrial tachycardia after circumferential pulmonary vein ablation for atrial fibrillation

Open access
Mesas, C.ézar E., Pappone, Carlo, Lang, Christopher C.E., Gugliotta, Filippo, Tomita, Takeshi, Vicedomini, Gabriele, Sala, Simone, Paglino, Gabriele, Gulletta, Simone, Ferro, Amedeo, Santinelli, Vincenzo · 2004 · Journal of the American College of Cardiology

Abstract

OBJECTIVES The purpose of this study was to evaluate the electroanatomic characteristics of left atrial tachycardia (AT) in a series of patients who underwent circumferential pulmonary vein ablation (CPVA) and to describe the ablation strategy and clinical outcome. BACKGROUND Circumferential pulmonary vein ablation is an effective treatment for atrial fibrillation. A potential midterm complication is the development of left AT. There are only isolated reports describing mapping and ablation of such arrhythmias. METHODS Thirteen patients (age 57.4 +/- 8.9 years, five female) underwent mapping and ablation of 14 left ATs via an electroanatomic mapping system a mean of 2.6 +/- 1.6 months after CPVA. RESULTS Three patients were characterized as having focal AT (cycle length: 266 +/- 35.9 ms). Of 11 macro-re-entrant tachycardias studied in the remaining 10 patients (cycle length: 275 +/- 75 ms), 5 showed single-loop and 6 dual-loop circuits. Re-entrant circuits used the mitral isthmus, the posterior wall, or gaps on previous encircling lines. Such gaps and all three foci occurred anterior to the left superior pulmonary vein or at the septal aspect of the right pulmonary veins. Thirteen of 14 tachycardias (93%) were successfully ablated. CONCLUSIONS Left AT after CPVA can be due to a macro-re-entrant or focal mechanism. Re-entry occurs most commonly across the mitral isthmus, the posterior wall, or gaps on previous ablation lines. Such gaps and foci occur most commonly at the anterior aspect of the left superior pulmonary vein and at the septal aspect of the right pulmonary veins. These arrhythmias can be successfully mapped and ablated with an electroanatomic mapping system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2004.05.072

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 219

Metadata

Authors
Mesas, C. É. E., Pappone, C., Lang, C. C. E., Gugliotta, F., Tomita, T., Vicedomini, G., Sala, S., Paglino, G., Gulletta, S., Ferro, A., & Santinelli, V.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2004-09
Volume
44
Issue
5
Pages
1071-1079
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2164929379
Cited by
219
References
2
FWCI
15.70
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.