Abstract

OBJECTIVES This study was designed to assess the feasibility and safety of a Remote Navigation System (RNS, NaviCath, Haifa, Israel) in which the angioplasty guidewire, the balloon, and the stent are navigated via a computerized system. BACKGROUND Percutaneous coronary interventions (PCIs) are manually performed under fluoroscopic guidance, requiring lead protection for the operators. A system in which the operator can remotely, safely, and precisely navigate the procedure during PCI would have clear advantages. METHODS The RNS involves a computer-controlled wire and delivery system navigator. Following preclinical validation, the system was assessed in patients undergoing single-vessel PCI. RESULTS The study involved 18 patients (age 55.9 years, 16% women). The RNS successfully crossed lesions with the guidewire in 17 patients. The stent was then advanced by the advance/rotate mode and adequately positioned in 15 of 17 cases. Technical malfunction was encountered in three patients in whom the procedure was successfully completed manually. Direct stenting was employed in 10 of 18 patients, pre-dilation in 7 patients, and after-stent balloon dilation in 5 patients. The total fluoroscopy time for 17 RNS patients was compared with the corresponding time of 20 consecutive patients who underwent standard single-lesion PCI. Fluoroscopy time was similar for both procedures, with 8.8 +/- 4.8 min with the RNS versus 9.1 +/- 3.5 min with the standard techniques (p = NS). Clinical success was 100% and technical success 94% for the guidewire and 83% for the overall procedure. CONCLUSIONS The use of the RNS for guidewire, balloon, and stent manipulation during PCI appears safe and feasible for the treatment of patients with coronary stenosis. The system offers operator radiation safety and may enhance precision of stent placement and balloon dilation strategies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2005.09.024

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 186

Metadata

Authors
Beyar, R., Gruberg, L., Deleanu, D., Roguin, A., Almagor, Y., Cohen, S., Kumar, G., & Wenderow, T.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2006-01
Volume
47
Issue
2
Pages
296-300
ISSN
0735-1097 (ISSN-L)
OpenAlex
W85086260
Cited by
186
References
10
FWCI
4.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.