The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Treatment of Calcific Aortic Stenosis With the Percutaneous Heart Valve
Open accessAbstract
OBJECTIVES The aim of this work was to study the feasibility, safety, efficacy, and durability of percutaneous heart valve (PHV) implantation in the aortic position. BACKGROUND We developed a PHV (equine pericardium valve in a balloon-expandable, stainless-steel stent) to treat patients with inoperable aortic stenosis (AS). METHODS Thirty-six patients (aortic valve area < or =0.7 cm2, New York Heart Association [NYHA] functional class IV, and severe comorbidities), formally declined for surgery, were recruited on a compassionate basis. The PHV was implanted by retrograde or antegrade trans-septal approach. Clinical and echocardiographic outcomes were assessed serially. RESULTS Twenty-seven patients were implanted successfully (23 antegrade, 4 retrograde) in the subcoronary position with improvement in valve area (0.60 +/- 0.11 cm2 to 1.70 +/- 0.10 cm2, p < 0.0001) and transvalvular gradient (37 +/- 13 mm Hg to 9 +/- 2 mm Hg, p < 0.0001). Paravalvular aortic regurgitation was grade 0 to 1 (n = 10), grade 2 (n = 12), and grade 3 (n = 5). One week post-procedure, improvement in left ventricular function (45 +/- 18% to 53 +/- 14%, p = 0.02) was most pronounced in patients with ejection fraction <50% (35 +/- 10% to 50 +/- 16%, p < 0.0001). Thirty-day major adverse events after successful implantation were 26% (pericardial tamponade, stroke, arrhythmia, urosepsis, and one death unexplained at autopsy). Eleven patients are currently alive with follow-up of 9 months (n = 2), 10 months (n = 3), 11 months (n = 1), 12 months (n = 2), 23 months (n = 1), and 26 months (n = 2). All patients experienced amelioration of symptoms (>90% NYHA functional class I to II). Percutaneous heart valve function remained unchanged during follow-up, and no deaths were device-related. CONCLUSIONS Percutaneous heart valve implantation is feasible in inoperable patients with end-stage AS leading to hemodynamic and clinical improvement. Continued advances and improved patient selection should decrease adverse events in the near future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zoghbi, W. A., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Kraft, C. D., Levine, R. A., Nihoyannopoulos, P., Otto, C. M., Quinones, M. A., Rakowski, H., et al. (2003) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(03)00335-3 · Cited by 4,044
Iung, B. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00201-x · Cited by 3,530
European system for cardiac operative risk evaluation (EuroSCORE)
Nashef, S. A. M., Roques, F., Michel, P., Gauducheau, E., Lemeshow, S., & Salamon, R. (1999) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(99)00134-7 · Cited by 3,362
Cribier, A., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Derumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,172
Self-citationEurp-pean system for cardiac operative risk evaluation (Euro SCORE)
Nashef, S. A. M. (1999) · Medical Entomology and Zoology · Cited by 1,349
Cribier, A., Saoudi, N., Berland, J., Savin, T., Rocha, P., & Letac, B. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90716-6 · Cited by 668
Self-citationITALIAN AND ENGLISH SYSTEMS OF MEDICAL INSTRUCTION.
(1824) · The Lancet · doi:10.1016/s0140-6736(02)95345-6 · Cited by 664
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Sebagh, L., Bash, A., Nusimovici, D., Litzler, P. Y., Bessou, J.-P., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.11.026 · Cited by 644
Self-citationObserved and relative survival after aortic valve replacement
Kvidal, P., Bergström, P. R., Hörte, L.-G., & Ståhle, E. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00584-7 · Cited by 525
ANDERSEN, H. R., KNUDSEN, L. L., & HASENKAM, J. M. (1992) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060238 · Cited by 491
Cardiac surgery in octogenarians. Peri-operative outcome and long-term results
Kolh, P. (2001) · European Heart Journal · doi:10.1053/euhj.2000.2443 · Cited by 217
Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis
Cribier, A. G., Eltchaninoff, H., & Bash, A. (2003) · ACC Current Journal Review · doi:10.1016/s1062-1458(03)00094-1 · Cited by 151
Self-citationBauer, F., Eltchaninoff, H., Tron, C., Lesault, P., Agatiello, C. R., Nercolini, D. C., Dérumeaux, G., & Cribier, A. G. (2004) · Circulation · doi:10.1161/01.cir.0000134961.36773.d6 · Cited by 149
Self-citationTarantini, G., Buja, P., Scognamiglio, R., Razzolini, R., Gerosa, G., Isabella, G., Ramondo, A., & Iliceto, S. (2003) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(03)00575-x · Cited by 121
Cardiac surgery in octogenarians
Ishikawa, S., Buxton, B. F., Manson, N., Hadj, A., Seevanayagam, S., Raman, J., Rosalion, A., & Morishita, Y. (2004) · ANZ Journal of Surgery · doi:10.1111/j.1445-1433.2004.03214.x · Cited by 100
Percutaneous Implantation of Aortic Valve Prosthesis in Patients with Calcific Aortic Stenosis:
Eltchaninoff, H., Tron, C., & Cribier, A. G. (2003) · Journal of Interventional Cardiology · doi:10.1046/j.1540-8183.2003.01051.x · Cited by 42
Self-citationEvaluation of restenosis after balloon dilatation in adult aortic stenosis by repeat catheterization
Letac, B., Cribier, A. G., Eltchaninoff, H., Köning, R., & Dérumeaux, G. (1991) · American Heart Journal · doi:10.1016/0002-8703(91)90758-a · Cited by 33
Self-citation
Cited by
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationAuthors/Task Force Members, Vahanian, A., Baumgartner, H., Bax, J., Butchart, E., Dion, R., Filippatos, G., Flachskampf, F., Hall, R., Iung, B., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl428 · Cited by 3,593
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Tamburino, C., Capodanno, D., Ramondo, A., Petronio, A. S., Ettori, F., Santoro, G., Klugmann, S., Bedogni, F., Maisano, F., Marzocchi, A., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.946533 · Cited by 1,124
Metadata
- Authors
- Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Nercolini, D., Tapiero, S., Litzler, P.-Y., Bessou, J.-P., & Babaliaros, V.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2006-03
- Volume
- 47
- Issue
- 6
- Pages
- 1214-1223
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W180423479
- Cited by
- 715
- References
- 17
- FWCI
- 47.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.