OBJECTIVES The purpose of this study was to compare left ventricular (LV) dyssynchrony assessment by gated myocardial perfusion single-photon emission computed tomography (SPECT) (GMPS) and tissue Doppler imaging (TDI). BACKGROUND Recently, it has been suggested that LV dyssynchrony is an important predictor of response to cardiac resynchronization therapy (CRT); dyssynchrony is predominantly assessed by TDI with echocardiography. Information on LV dyssynchrony can also be provided by GMPS with phase analysis of regional LV maximal count changes throughout the cardiac cycle, which tracks the onset of LV thickening. METHODS In 75 patients with heart failure, depressed LV function, and wide QRS complex, GMPS and 2-dimensional echocardiography, including TDI, were performed as part of clinical screening for eligibility for CRT. Clinical status was evaluated with New York Heart Association functional classification, 6-min walk distance, and quality-of-life score. Different parameters (histogram bandwidth, phase SD, histogram skewness, and histogram kurtosis) of LV dyssynchrony were assessed from GMPS and compared with LV dyssynchrony on TDI with Pearson's correlation analyses. RESULTS Histogram bandwidth and phase SD correlated well with LV dyssynchrony assessed with TDI (r = 0.89, p < 0.0001 and r = 0.80, p < 0.0001, respectively). Histogram skewness and kurtosis correlated less well with LV dyssynchrony on TDI (r = -0.52, p < 0.0001 and r = -0.45, p < 0.0001, respectively). CONCLUSIONS The LV dyssynchrony assessed from GMPS correlated well with dyssynchrony assessed by TDI; histogram bandwidth and phase SD showed the best correlation with LV dyssynchrony on TDI. These parameters seem most optimal for assessment of LV dyssynchrony with gated SPECT. Outcome studies after CRT are needed to further validate the use of GMPS for assessment of LV dyssynchrony.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2007.01.063

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 205

Metadata

Authors
Henneman, M. M., Chen, J., Ypenburg, C., Dibbets, P., Bleeker, G. B., Boersma, E., Stokkel, M. P., van der Wall, E. E., Garcia, E. V., & Bax, J. J.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2007-04
Volume
49
Issue
16
Pages
1708-1714
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2042759815
Cited by
205
References
3
FWCI
13.18
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.