Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 300

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Can LV Dyssynchrony as Assessed with Phase Analysis on Gated Myocardial Perfusion SPECT Predict Response to CRT?

Open access
Henneman, M. M., Chen, J., Dibbets-Schneider, P., Stokkel, M. P., Bleeker, G. B., Ypenburg, C., van der Wall, E. E., Schalij, M. J., Garcia, E. V., Bax, J. J.·2007·Journal of Nuclear Medicine

Abstract

UNLABELLED: Cardiac resynchronization therapy (CRT) is now a well-recognized therapeutic option for patients with end-stage heart failure. However, not all patients respond to CRT, and, therefore, preimplantation identification of responders is desirable. The aim of the present study was to investigate whether the degree of left ventricular (LV) dyssynchrony, as assessed with phase analysis from gated myocardial perfusion SPECT (GMPS), can predict which patients will respond to CRT. METHODS: Forty-two patients with severe heart failure, depressed LV ejection fraction, and wide QRS complex were prospectively included for implantation of a CRT device and underwent GMPS and 2-dimensional echocardiography as part of the clinical protocol. Clinical status was evaluated using the New York Heart Association (NYHA) classification, 6-min walk test, and quality-of-life score. The histogram bandwidth and phase SD (parameters indicating LV dyssynchrony) were assessed from GMPS, and the clinical status and echocardiographic variables were reassessed at 6-mo follow-up. RESULTS: Responders (71%) and nonresponders (29%) had comparable baseline characteristics, except for histogram bandwidth (175 degrees +/- 63 degrees vs. 117 degrees +/- 51 degrees [P < 0.01]) and phase SD (56.3 degrees +/- 19.9 degrees vs. 37 degrees .1 +/- 14.4 degrees [P < 0.01]), which were significantly larger in responders compared with nonresponders. Moreover, receiver-operating-characteristic curve analysis demonstrated an optimal cutoff value of 135 degrees for histogram bandwidth (sensitivity and specificity of 70%) and of 43 degrees for phase SD (sensitivity and specificity of 74%) for the prediction of response to CRT. CONCLUSION: Response to CRT is related to the presence of LV dyssynchrony assessed by phase analysis with GMPS. A cutoff value of 135 degrees for histogram bandwidth and of 43 degrees for phase SD could be used to predict response to CRT. Larger prospective studies are warranted to confirm the present findings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.107.039925

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 300

Metadata

Authors
Henneman, M. M., Chen, J., Dibbets-Schneider, P., Stokkel, M. P., Bleeker, G. B., Ypenburg, C., van der Wall, E. E., Schalij, M. J., Garcia, E. V., & Bax, J. J.
Venue
Journal of Nuclear Medicine
Published
2007-07-01
Volume
48
Issue
7
Pages
1104-1111
ISSN
0161-5505 (ISSN-L)
OpenAlex
W2158309731
Cited by
300
References
32
FWCI
14.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Can LV Dyssynchrony as Assessed with Phase Analysis on Gated Myocardial Perfusion SPECT Predict Response to CRT? https://app.cochat.ai/papers/10.2967/jnumed.107.039925
The paper
Henneman, M. M., Chen, J., Dibbets-Schneider, P., Stokkel, M. P., Bleeker, G. B., Ypenburg, C., van der Wall, E. E., Schalij, M. J., Garcia, E. V., & Bax, J. J. (2007). Can LV Dyssynchrony as Assessed with Phase Analysis on Gated Myocardial Perfusion SPECT Predict Response to CRT? Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.107.039925

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.