The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Initial Worldwide Experience With the WATCHMAN Left Atrial Appendage System for Stroke Prevention in Atrial Fibrillation
Open accessAbstract
OBJECTIVES This study assessed the feasibility of implanting a device in the left atrial appendage (LAA) in patients with atrial fibrillation (AF) to prevent thromboembolic stroke. BACKGROUND Meta-analyses confirmed that in cases of left atrial thrombus in nonrheumatic AF patients approximately 90% of them are in the LAA. METHODS The WATCHMAN Left Atrial Appendage System (Atritech Inc., Plymouth, Minnesota) is a nitinol device implanted percutaneously to seal the LAA. Patients were followed by clinical and transesophageal echocardiography at 45 days and 6 months with annual clinical follow-up thereafter. RESULTS Sixty-six patients underwent device implantation. Mean follow-up was 740 +/- 341 days. At 45 days, 93% (54 of 58) devices showed successful sealing of LAA according to protocol. Two patients experienced device embolization, both successfully retrieved percutaneously. No embolizations occurred in 53 patients enrolled after modification of fixation barbs. There were 2 cardiac tamponades, 1 air embolism, and 1 delivery wire fracture (first generation) with surgical explantation but no long-term sequelae for the patient. Four patients developed a flat thrombus layer on the device at 6 months that resolved with additional anticoagulation. Two patients experienced transient ischemic attack, 1 without visible thrombus. There were 2 deaths, neither device related. Autopsy documented a stable, fully endothelialized device 9 months after implantation. No strokes occurred during follow-up despite >90% of patients with discontinuation of anticoagulation. CONCLUSIONS Preliminary data suggest LAA occlusion with the WATCHMAN System to be safe and feasible. A randomized study is ongoing comparing oral anticoagulation with percutaneous closure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kannel, W. B., Wolf, P. A., Benjamin, E. J., & Levy, D. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00583-9 · Cited by 2,033
Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation
Blackshear, J. L., & Odell, J. A. (1996) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00887-x · Cited by 1,686
Secular trends in the prevalence of atrial fibrillation: The Framingham study
Wolf, P. A., Benhamin, E. J., Belanger, A. J., Kannel, W. B., Levy, D., & D'Agostino, R. B. (1996) · American Heart Journal · doi:10.1016/s0002-8703(96)90288-4 · Cited by 446
Cited by
Reddy, V. Y., Sievert, H., Halperin, J., Doshi, S. K., Buchbinder, M., Neuzil, P., Huber, K., Whisenant, B., Kar, S., Swarup, V., et al. (2014) · JAMA · doi:10.1001/jama.2014.15192 · Cited by 1,018
Self-citationReddy, V. Y., Doshi, S. K., Sievert, H., Buchbinder, M., Neuzil, P., Huber, K., Halperin, J. L., & Holmes, D. (2013) · Circulation · doi:10.1161/circulationaha.112.114389 · Cited by 677
Self-citationPark, J., Bethencourt, A., Sievert, H., Santoro, G., Meier, B., Walsh, K., Lopez‐Minquez, J. R., Meerkin, D., Valdés, M., Ormerod, O., et al. (2011) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22764 · Cited by 423
Metadata
- Authors
- Sick, P. B., Schuler, G., Hauptmann, K. E., Grube, E., Yakubov, S., Turi, Z. G., Mishkel, G., Almany, S., & Holmes, D. R.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2007-04
- Volume
- 49
- Issue
- 13
- Pages
- 1490-1495
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2111395084
- Cited by
- 351
- References
- 3
- FWCI
- 17.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Initial Worldwide Experience With the WATCHMAN Left Atrial Appendage System for Stroke Prevention in Atrial Fibrillation. https://app.cochat.ai/papers/10.1016/j.jacc.2007.02.035
- The paper
- Sick, P. B., Schuler, G., Hauptmann, K. E., Grube, E., Yakubov, S., Turi, Z. G., Mishkel, G., Almany, S., & Holmes, D. R. (2007). Initial Worldwide Experience With the WATCHMAN Left Atrial Appendage System for Stroke Prevention in Atrial Fibrillation. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2007.02.035
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.