CoChat

Predictive Value of Microvolt T-Wave Alternans in Patients With Left Ventricular Dysfunction

Open access
Cantillon, Daniel J., Stein, Kenneth M., Markowitz, Steven M., Mittal, Suneet, Shah, Bindi K., Morin, Daniel P., Zacks, Eran S., Janik, Matthew, Ageno, Shaun, Mauer, Andreas C., Lerman, Bruce B., Iwai, Sei · 2007 · Journal of the American College of Cardiology
Cited by 66

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVES The purpose of this study was to prospectively evaluate the utility of microvolt T-wave alternans (TWA) in predicting arrhythmia-free survival and total mortality in patients with left ventricular (LV) dysfunction. BACKGROUND Microvolt TWA has been proposed as a useful tool in identifying patients unlikely to benefit from prophylaxis with implantable cardioverter-defibrillator (ICD) prophylaxis. METHODS We evaluated 286 patients with an LV ejection fraction </=35% who underwent TWA and electrophysiologic testing (EPS) owing to nonsustained ventricular tachycardia and/or syncope. Positive and indeterminate TWA results were grouped as non-negative. The primary end point was arrhythmia-free survival; the secondary end point was all-cause mortality. RESULTS Patients were followed for a mean of 38 +/- 11 months. There was no significant difference between the TWA-negative (n = 90; 31%) and non-negative (n = 196; 69%) groups with respect to ICD implant rates (54% vs. 64%, respectively; p = 0.95) or etiology of cardiomyopathy (ischemic: 73% vs. 76%; p = 0.71). The Kaplan-Meier curves demonstrated improved arrhythmia-free survival in TWA-negative patients (81% vs. 66% at 2 years; p < 0.001), including in both ischemic (79% vs. 64% at 2 years; p = 0.004) and nonischemic (88% vs. 71% at 2 years; p = 0.015) subgroups. Total mortality was lower in the TWA-negative group (10% vs. 18% at 2 years; p = 0.04). The negative predictive value of TWA for (2-year) total mortality was 90%, and 83% for EPS. CONCLUSION Microvolt TWA predicts arrhythmia-free survival among patients with LV dysfunction. However, the event rate in the TWA-negative group suggests that TWA may not be capable of identifying a sufficiently low-risk subset in this population to obviate the need for ICD implantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2007.02.069

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 66

Metadata

Authors
Cantillon, D. J., Stein, K. M., Markowitz, S. M., Mittal, S., Shah, B. K., Morin, D. P., Zacks, E. S., Janik, M., Ageno, S., Mauer, A. C., Lerman, B. B., & Iwai, S.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2007-07
Volume
50
Issue
2
Pages
166-173
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1987730447
Cited by
66
References
2
FWCI
6.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predictive Value of Microvolt T-Wave Alternans in Patients With Left Ventricular Dysfunction. https://app.cochat.ai/papers/10.1016/j.jacc.2007.02.069
The paper
Cantillon, D. J., Stein, K. M., Markowitz, S. M., Mittal, S., Shah, B. K., Morin, D. P., Zacks, E. S., Janik, M., Ageno, S., Mauer, A. C., Lerman, B. B., & Iwai, S. (2007). Predictive Value of Microvolt T-Wave Alternans in Patients With Left Ventricular Dysfunction. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2007.02.069

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.