Objectives The purpose of this trial was to determine whether microvolt T-wave alternans (MTWA) predicts ventricular tachyarrhythmic events (VTEs) in post-myocardial infarction patients with left ventricular ejection fraction (LVEF) < or =30%.Background Previous studies have established MTWA as a predictor for total and arrhythmic mortality, but its ability to identify prophylactic implantable cardioverter-defibrillator (ICD) recipients most likely to experience VTEs remains uncertain.Methods This prospective trial was conducted at 50 U.S. centers. Patients were eligible if they met MADIT-II (Multicenter Automatic Defibrillator Implantation Trial II) indications for device implant. All patients underwent MTWA testing followed by ICD implantation, with pre-specified programming to minimize the likelihood of therapies for non-life-threatening VTE. Minimum follow-up was 2 years with annual MTWA testing. Initially indeterminate MTWA tests were repeated.Results Analyses were conducted on 575 patients (84% male; average age +/- SD = 65 +/- 11 years; average LVEF +/- SD = 0.24 +/- 0.05). The final distribution of MTWA results were: MTWA positive in 293 (51%), MTWA negative in 214 (37%), and indeterminate in 68 patients (12%). Over an average follow-up of 2.1 +/- 0.9 years, there were 70 VTEs. A VTE occurred in 48 of 361 (13%, 6.3%/year) MTWA non-negative and 22 of 214 (10%, 5.0%/year) MTWA negative patients. A non-negative MTWA test result was not associated with VTE (hazard ratio: 1.26; 95% confidence interval: 0.76 to 2.09; p = 0.37), although total mortality was significantly increased (hazard ratio: 2.04; 95% confidence interval: 1.10 to 3.78; p = 0.02).Conclusions In MADIT-II-indicated ICD-treated patients, the risk of VTE does not differ according to MTWA classification, despite differences in total mortality. (MASTER I-Microvolt T Wave Alternans Testing for Risk Stratification of Post MI Patients; NCT00305240).

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2008.08.018

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Microvolt T-wave alternans classification did not predict the risk of ventricular tachyarrhythmic events in ICD-treated patients, although total mortality was significantly increased if MTWA was positive.

    “Microvolt T-wave alternans (MTWA) classification did not predict the risk of ventricular tachyarrhythmic events in ICD treated patients, although total mortality was significantly increased if MTWA was positive.20”

    From The Year of 2008 in Electrocardiology (2010) · cites this paper as [20]

Cites

Flagged first, then by citations

1 of the 30 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Chow, T., Kereiakes, D. J., Onufer, J., Woelfel, A., Gursoy, S., Peterson, B. J., Brown, M. L., Pu, W., & Benditt, D. G.
Affiliations
  • Christ Hospital (US)
  • Medtronic (United States) (US)
  • University of Minnesota (US)
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2008-11
Volume
52
Issue
20
Pages
1607-1615
ISSN
0735-1097 (ISSN-L)
OpenAlex
W84927980
Cited by
201
References
30
Citations by year
2024: 3 · 2023: 4 · 2022: 6 · 2021: 5 · 2020: 3 · 2019: 3 · 2018: 11 · 2017: 12 · 2016: 10 · 2015: 12 · 2014: 11 · 2013: 21 · 2012: 23
FWCI
18.68
Type
journal article
Language
en
Open access
Locations
  • Journal of the American College of Cardiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
Medtronic
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
Keywords
microvolt T-wave alternans, ventricular tachyarrhythmia, ischemic cardiomyopathy, implantable cardioverter-defibrillator, MADIT II, myocardial infarction, left ventricular ejection fraction, arrhythmia risk prediction, all-cause mortality
MeSH terms
Aged, Female, Heart Function Tests, Humans, Male, Middle Aged, Cardiomyopathies, Prospective Studies, Defibrillators, Implantable, Tachycardia, Ventricular, Myocardial Ischemia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review