Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 368

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Cardiac Sympathetic Denervation Assessed With 123-Iodine Metaiodobenzylguanidine Imaging Predicts Ventricular Arrhythmias in Implantable Cardioverter-Defibrillator Patients

Open access
Boogers, Mark J., Borleffs, C. Jan Willem, Henneman, Maureen M., van Bommel, Rutger J., van Ramshorst, Jan, Boersma, Eric, Dibbets-Schneider, Petra, Stokkel, Marcel P., van der Wall, Ernst E., Schalij, Martin J., Bax, Jeroen J.·2010·Journal of the American College of Cardiology

Abstract

OBJECTIVES The purpose of this study was to evaluate whether 123-iodine metaiodobenzylguanidine (123-I MIBG) imaging predicts ventricular arrhythmias causing appropriate implantable cardioverter-defibrillator (ICD) therapy (primary end point) and the composite of appropriate ICD therapy or cardiac death (secondary end point). BACKGROUND Although cardiac sympathetic denervation is associated with ventricular arrhythmias, limited data are available on the predictive value of sympathetic nerve imaging with 123-I MIBG on the occurrence of arrhythmias. METHODS Before ICD implantation, patients underwent 123-I MIBG and myocardial perfusion imaging. Early and late 123-I MIBG (planar and single-photon emission computed tomography [SPECT]) imaging was performed to assess cardiac innervation (heart-to-mediastinum ratio, cardiac washout rate, and 123-I MIBG SPECT defect score). Stress-rest myocardial perfusion imaging was performed to assess myocardial infarction and perfusion abnormalities (perfusion defect scores). During follow-up, appropriate ICD therapy and cardiac death were documented. RESULTS One-hundred sixteen heart failure patients referred for ICD therapy were enrolled. During a mean follow-up of 23 +/- 15 months, appropriate ICD therapy (primary end point) was documented in 24 (21%) patients and appropriate ICD therapy or cardiac death (secondary end point) in 32 (28%) patients. Late 123-I MIBG SPECT defect score was an independent predictor for both end points. Patients with a large late 123-I MIBG SPECT defect (summed score >26) showed significantly more appropriate ICD therapy (52% vs. 5%, p < 0.01) and appropriate ICD therapy or cardiac death (57% vs. 10%, p < 0.01) than patients with a small defect (summed score </=26) at 3-year follow-up. CONCLUSIONS Cardiac sympathetic denervation predicts ventricular arrhythmias causing appropriate ICD therapy as well as the composite of appropriate ICD therapy or cardiac death.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2009.12.066

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 368

Metadata

Authors
Boogers, M. J., Borleffs, C. J. W., Henneman, M. M., van Bommel, R. J., van Ramshorst, J., Boersma, E., Dibbets-Schneider, P., Stokkel, M. P., van der Wall, E. E., Schalij, M. J., & Bax, J. J.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2010-06
Volume
55
Issue
24
Pages
2769-2777
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2050661659
Cited by
368
References
29
FWCI
17.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiac Sympathetic Denervation Assessed With 123-Iodine Metaiodobenzylguanidine Imaging Predicts Ventricular Arrhythmias in Implantable Cardioverter-Defibrillator Patients. https://app.cochat.ai/papers/10.1016/j.jacc.2009.12.066
The paper
Boogers, M. J., Borleffs, C. J. W., Henneman, M. M., van Bommel, R. J., van Ramshorst, J., Boersma, E., Dibbets-Schneider, P., Stokkel, M. P., van der Wall, E. E., Schalij, M. J., & Bax, J. J. (2010). Cardiac Sympathetic Denervation Assessed With 123-Iodine Metaiodobenzylguanidine Imaging Predicts Ventricular Arrhythmias in Implantable Cardioverter-Defibrillator Patients. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2009.12.066

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.