Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 237

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Characterization of the Arrhythmogenic Substrate in Ischemic and Nonischemic Cardiomyopathy

Open access
Nakahara, Shiro, Tung, Roderick, Ramirez, Rafael J., Michowitz, Yoav, Vaseghi, Marmar, Buch, Eric, Gima, Jean, Wiener, Isaac, Mahajan, Aman, Boyle, Noel G., Shivkumar, Kalyanam·2010·Journal of the American College of Cardiology

Abstract

Objective The purpose of this study was to compare the characteristics and prevalence of late potentials (LP) in patients with cardiomyopathy of nonischemic (NICM) and ischemic (ICM) etiologies and evaluate their value as targets for catheter ablation. Background LPs are frequently found in postmyocardial infarction scars and are useful ablation targets. The relative prevalence and characteristics of LPs in patients with NICM is not well understood. Methods Thirty-three patients with structural heart disease (NICM 16, ICM 17) referred for catheter ablation of ventricular tachycardia (VT) were studied. Electroanatomic mapping was performed endocardially (n=33) and epicardially (n=19). LPs were defined as low voltage electrograms (<1.5 mV) with onset after the QRS. Very late potentials (vLP) were defined as electrograms with onset >100ms after the QRS. Results We sampled an average of 564±449/726±483 points in the LV endocardium/epicardium. Mean total low voltage area (TLV) in patients with ICM was 101±55/56±33cm2 (endocardial/epicardial, respectively), compared to NICM (55±41/53±28cm2). Within TLV, vLP were observed more frequently in ICM than NICM in endocardium (4.1% vs. 1.3%; p=0.0003) and epicardium (4.3% vs. 2.1%, p=0.035). An LP-targeted ablation strategy was effective in ICM patients (82% nonrecurrence at 12±10months follow-up), while NICM patients had less favorable outcomes (50% at 15±13months follow-up). Conclusion The contribution of scar to the electrophysiological abnormalities targeted for ablation of unstable VT differs between ICM and NICM. An approach incorporating LP ablation and pace-mapping had limited success in patients with NICM compared to ICM and alternative ablation strategies should be considered.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2010.01.041

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 237

Metadata

Authors
Nakahara, S., Tung, R., Ramirez, R. J., Michowitz, Y., Vaseghi, M., Buch, E., Gima, J., Wiener, I., Mahajan, A., Boyle, N. G., & Shivkumar, K.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2010-05
Volume
55
Issue
21
Pages
2355-2365
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1585260149
Cited by
237
References
1
FWCI
11.24
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterization of the Arrhythmogenic Substrate in Ischemic and Nonischemic Cardiomyopathy. https://app.cochat.ai/papers/10.1016/j.jacc.2010.01.041
The paper
Nakahara, S., Tung, R., Ramirez, R. J., Michowitz, Y., Vaseghi, M., Buch, E., Gima, J., Wiener, I., Mahajan, A., Boyle, N. G., & Shivkumar, K. (2010). Characterization of the Arrhythmogenic Substrate in Ischemic and Nonischemic Cardiomyopathy. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2010.01.041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.