CoChat

Optical Mapping of the Isolated Coronary-Perfused Human Sinus Node

Open access
Fedorov, Vadim V., Glukhov, Alexey V., Chang, Roger, Kostecki, Geran, Aferol, Hyuliya, Hucker, William J., Wuskell, Joseph P., Loew, Leslie M., Schuessler, Richard B., Moazami, Nader, Efimov, Igor R. · 2010 · Journal of the American College of Cardiology
Cited by 157

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background The site of origin and pattern of excitation within the human sinoatrial node (SAN) has not been directly mapped. Objective We hypothesized that the human SAN is functionally insulated from the surrounding atrial myocardium except for several exit pathways which electrically bridge the nodal tissue and atrial myocardium. Methods The SAN was optically mapped in coronary perfused preparations from non-failing human hearts (n=4, age 54±15 years) using dye Di-4-ANBDQBS and Blebbistatin. SAN 3D structure was reconstructed using histology. Results Optical recordings from the SAN had diastolic depolarization and multiple upstroke components, which corresponded to the separate excitations of the SAN and atrial layers. Excitation originated in the middle of the SAN (66±17 BPM), then slowly (1–18 cm/s) and anisotropically spread. After a 82±17 ms conduction delay within the SAN, the atrial myocardium was excited via superior, middle, and/or inferior sinoatrial conduction pathways. Atrial excitation was initiated 9.4±4.2 mm from the leading pacemaker site. The oval 14.3±1.5 × 6.7±1.6 × 1.0±0.2 mm SAN structure was functionally insulated from the atrium by connective tissue, fat, and coronary arteries, except for these pathways. Conclusion These data demonstrated for the first time the location of the leading SAN pacemaker site, the pattern of excitation within the human SAN, and the conduction pathways into the right atrium. The existence of these pathways explained why, even during normal sinus rhythm, atrial breakthroughs could arise from a region parallel to the CT that is significantly larger (26.0±7.8 mm) than the area of the anatomically defined SAN.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2010.03.098

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 157

Metadata

Authors
Fedorov, V. V., Glukhov, A. V., Chang, R., Kostecki, G., Aferol, H., Hucker, W. J., Wuskell, J. P., Loew, L. M., Schuessler, R. B., Moazami, N., & Efimov, I. R.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2010-10
Volume
56
Issue
17
Pages
1386-1394
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2142830159
Cited by
157
References
2
FWCI
7.36
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optical Mapping of the Isolated Coronary-Perfused Human Sinus Node. https://app.cochat.ai/papers/10.1016/j.jacc.2010.03.098
The paper
Fedorov, V. V., Glukhov, A. V., Chang, R., Kostecki, G., Aferol, H., Hucker, W. J., Wuskell, J. P., Loew, L. M., Schuessler, R. B., Moazami, N., & Efimov, I. R. (2010). Optical Mapping of the Isolated Coronary-Perfused Human Sinus Node. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2010.03.098

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.