The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Aggregate National Experience With the Wearable Cardioverter-Defibrillator
Open accessAbstract
Objectives The purpose of this study was to determine patient compliance and effectiveness of antiarrhythmic treatment by the wearable cardioverter-defibrillator (WCD).Background Effectiveness of the WCD for prevention of sudden death is dependent on event type, patient compliance, and appropriate management of ventricular tachycardia/ventricular fibrillation (VT/VF).Methods Compliance and events were recorded in a nationwide registry of post-market release WCDs. Survival, using the Social Security Death Index, was compared with survival in implantable cardioverter-defibrillator (ICD) patients.Results Of 3,569 patients wearing the WCD (age 59.3+/-14.7 years, duration 52.6+/-69.9 days), daily use was 19.9+/-4.7 h (>90% of the day) in 52% of patients. More days of use correlated with higher daily use (p<0.001). Eighty sustained VT/VF events occurred in 59 patients (1.7%). First-shock success was 76 of 76 (100%) for unconscious VT/VF and 79 of 80 (99%) for all VT/VF. Eight patients died after successful conversion of unconscious VT/VF (89.5% survival of VT/VF events). Asystole occurred in 23 (17 died), pulseless electrical activity in 2, and respiratory arrest in 1 (3 died), representing 24.5% of sudden cardiac arrests. During WCD use, 3,541 of 3,569 patients (99.2%) survived overall. Survival occurred in 72 of 80 (90%) VT/VF events and 78 of 106 (73.6%) for all events. Long-term mortality was not significantly different from first ICD implant patients but highest among patients with traditional ICD indications.Conclusions Compliance was satisfactory with 90% wear time in >50% of patients and low sudden death mortality during use. Survival was comparable to that of ICD patients. However, asystole was an important cause of mortality in sudden cardiac arrest events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“LiveVest showed comparable outcomes to implantable cardiac devices in a 3-year study (n = 3569) with acute event survival at 99.2% [38].”
From Wearables and the Medical Revolution (2018) · cites this paper as [38]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
The AVID Investigators (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,221
Oss, J. M., Areba, W. O. Z., Ackson, W. J., Lein, H. E. K., Ilber, D. A. J. W., Annom, D. A. S. C., Ames, J. M., Aubert, P., Iggins, S. T. L. H., Rown, M. A. W. B., et al. (2002) · Cited by 2,026
Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction
Hohnloser, S. H., Kuck, K. H., Dorian, P., Roberts, R. S., Hampton, J. R., Hatala, R., Fain, E., Gent, M., & Connolly, S. J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041489 · Cited by 1,519
Solomon, S. D., Zelenkofske, S., McMurray, J. J. V., Finn, P. V., Velazquez, E. J., Ertl, G., Harsanyi, A., Rouleau, J. L., Maggioni, A. P., Køber, L., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043938 · Cited by 800
Impact of Medication Therapy Discontinuation on Mortality After Myocardial Infarction
Ho, P. M., Spertus, J. A., Masoudi, F. A., Reid, K. J., Peterson, E. D., Magid, D. J., Krumholz, H. M., & Rumsfeld, J. S. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.17.1842 · Cited by 635
(2005) · New England Journal of Medicine · doi:10.1056/nejm200508183530725 · Cited by 601
Friedman, P. A., McClelland, R. L., Bamlet, W. R., Acosta, H., Kessler, D. J., Munger, T. M., Kavesh, N. G., Wood, M., Daoud, E. G., Massumi, A., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.594531 · Cited by 255
Flagged first, then by citations
Cited by
Sorted by citations
Items 101–200 of 296
Niwano, S., Sekiguchi, Y., Ishii, Y., Iwasaki, Y., Kato, R., Okamura, H., Takagi, M., Kurita, T., & Nitta, T. (2018) · Circulation Journal · doi:10.1253/circj.cj-17-1336 · Cited by 16
Stellungnahme zum Einsatz des tragbaren Kardioverter/Defibrillators
Schwab, J. O., Bänsch, D., Israel, C. W., & Nowak, B. (2015) · Der Kardiologe · doi:10.1007/s12181-015-0651-y · Cited by 16
Experience With Wearable Cardioverter-Defibrillators at 2 Academic Medical Centers
Leyton-Mange, J. S., Hucker, W. J., Mihatov, N., Reynolds, M. R., Albert, C. M., Lubitz, S. A., & Milan, D. J. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.09.180 · Cited by 16
Matteucci, A., Bonanni, M., Sgarra, L., Pignalberi, C., Aquilani, S., Fusco, S. A. D., Mariani, M. V., Pierucci, N., Lavalle, C., Fedele, S., et al. (2025) · Open Heart · doi:10.1136/openhrt-2025-003648 · Cited by 15
Quast, A. B. E., van Dijk, V. F., Wilde, A. A. M., Knops, R. E., & Boersma, L. V. A. (2017) · Netherlands Heart Journal · doi:10.1007/s12471-017-0957-4 · Cited by 15
Daimee, U. A., Vermilye, K., Moss, A. J., Goldenberg, I., Klein, H., McNitt, S. A., Zaręba, W., & Kutyifa, V. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.04.014 · Cited by 15
McGarry, T. J., Joshi, R., Kawata, H., Patel, J. D., Feld, G. K., Birgersdotter-Green, U. M., & Pretorius, V. G. (2013) · EP Europace · doi:10.1093/europace/eut305 · Cited by 15
Beiert, T., Malotki, R. J., Kraemer, N., Stöckigt, F., Linhart, M., Nickenig, G., SCHRICKEL, J. W., & Andrié, R. (2017) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2017.04.017 · Cited by 15
Echivard, M., Sellal, J., Ziliox, C., Marijon, É., Bordachar, P., Ploux, S., Bénali, K., Marquié, C., Docq, C., Klug, D., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae575 · Cited by 17
Use of the wearable cardioverter-defibrillator – the Swiss experience
Kovacs, B., Reek, S., Sticherling, C., Schaer, B. A., Linka, A., Ammann, P., Brenner, R., Krasniqi, N., Müller, A. S., Dzemali, O., et al. (2020) · Swiss Medical Weekly · doi:10.4414/smw.2020.20343 · Cited by 14
Boriani, G., Mantovani, L. G., Cortesi, P. A., Ponti, R. D., D’Onofrio, A., Arena, G., Curnis, A., Forleo, G. B., Guerra, F., Porcu, M., et al. (2021) · Clinical Cardiology · doi:10.1002/clc.23709 · Cited by 14
Zylla, M. M., Hillmann, H. A. K., Proctor, T., Kieser, M., Scholz, E., Zitron, E., Katus, H. A., & Thomas, D. (2018) · Heart and Vessels · doi:10.1007/s00380-018-1181-x · Cited by 14
Castro, L., Pecha, S., Linder, M., Vogler, J., Gosau, N., Meyer, C. G., Willems, S., Reichenspurner, H. C., & Hakmi, S. (2017) · Journal of Cardiothoracic Surgery · doi:10.1186/s13019-017-0669-2 · Cited by 13
Hillmann, H. A. K., Hohmann, S., Müller‐Leisse, J., Zormpas, C., Eiringhaus, J., Bauersachs, J. K., Veltmann, C., & Duncker, D. (2021) · Sensors · doi:10.3390/s21237798 · Cited by 13
El‐Battrawy, I., Kovacs, B., Dreher, T. C., Klein, N., Rosenkaimer, S., Röger, S., Kuschyk, J., Saguner, A. M., Kowitz, J., Erath, J. W., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-06007-y · Cited by 13
Tereshchenko, S. N., Жиров, И. В., Uskach, T. M., Saidova, M. A., Sp, G., Михайловна, Г. Е., Николаевна, Н. С., Narusov, O. Y., Safiullina, A. A., Tereshchenko, A. S., et al. (2020) · Eurasian heart journal · doi:10.38109/2225-1685-2020-3-6-76 · Cited by 12
Bunch, T. J., May, H. T., Bair, T. L., Crandall, B. G., Weiss, J. P., Osborn, J. S., Anderson, J. L., Muhlestein, J. B., Horne, B. D., LAPPE, D. L., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.03.052 · Cited by 12
NATIONAL EXPERIENCE WITH WEARABLE CARDIOVERTER-DEFIBRILLATOR USE IN TAKOTSUBO CARDIOMYOPATHY
Deeprasertkul, P., Opreanu, M., Bianco, N. R., & Thakur, R. K. (2013) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(13)60361-7 · Cited by 12
Sasaki, S., Shoji, Y., Ishida, Y., Kinjo, T., Tsushima, Y., Seno, M., Nishizaki, F., Itoh, T., Izumiyama, K., Yokota, T., et al. (2016) · Journal of Cardiology · doi:10.1016/j.jjcc.2016.08.004 · Cited by 12
Bayati, M., Hosseini, K., & Vasheghani-Farahani, A. (2019) · Current Cardiology Reviews · doi:10.2174/1573403x15666190118123754 · Cited by 12
Wearable cardioverter defibrillator: Bridge or alternative to implantation?
Barraud, J., Cautela, J., Orabona, M., Pinto, J., Missenard, O., Laine, M., Thuny, F., Paganelli, F. F., Bonello, L., & Peyrol, M. (2017) · HAL AMU · Cited by 12
Ventricular fibrillation cardiac arrest due to 5-fluorouracil cardiotoxicity.
Fradley, M. G., Barrett, C. D., Clark, J. R., & Francis, S. A. (2013) · Europe PMC (PubMed Central) · Cited by 12
Real world utilization and impact of the wearable cardioverter-defibrillator in a community setting
Naniwadekar, A., Alnabelsi, T. S., Joshi, K., Obasare, E. R., Greenspan, A. M., & Mainigi, S. K. (2017) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2017.01.003 · Cited by 12
Saad, T. F., & Weiner, H. L. (2017) · Seminars in Dialysis · doi:10.1111/sdi.12581 · Cited by 12
Wearable cardioverter defibrillator: Bridge or alternative to implantation?
Barraud, J., Cautela, J., Orabona, M., Pinto, J., Missenard, O., Laine, M., Thuny, F., Paganelli, F. F., Bonello, L., & Peyrol, M. (2017) · World Journal of Cardiology · doi:10.4330/wjc.v9.i6.531 · Cited by 12
Hanada, K., Sasaki, S., Seno, M., Kimura, Y., Ichikawa, H., Nishizaki, F., Yokoyama, H., Yokota, T., Okumura, K., & Tomita, H. (2022) · Circulation Journal · doi:10.1253/circj.cj-21-0999 · Cited by 12
Extended Use of the Wearable Cardioverter-Defibrillator: Which Patients Are Most Likely to Benefit?
Kovacs, B., Reek, S., Krasniqi, N., Eriksson, U., & Duru, F. (2018) · Cardiology Research and Practice · doi:10.1155/2018/7373610 · Cited by 11
Tripp, C., Burch, A. E., Erath, J. W., Hain, A., & Sears, S. F. (2020) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0000000000000454 · Cited by 11
Safety of the Wearable Cardioverter Defibrillator (WCD) in Patients with Implanted Pacemakers
Schmitt, J., ABACI, G., Johnson, V., Erkapic, D., Gemein, C., Chasan, R., Weipert, K. F., Hamm, C. W., & Klein, H. (2016) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12986 · Cited by 11
Barraud, J., Pinon, P., Laine, M., Cautela, J., Orabona, M., Koutbi, L., Pinto, J., Thuny, F., Franceschi, F., Paganelli, F. F., et al. (2017) · Heart Lung and Circulation · doi:10.1016/j.hlc.2017.08.022 · Cited by 11
Ellenbogen, K. A., Wan, C., & Shavelle, D. M. (2017) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2017.10.007 · Cited by 11
Another Shock for Sudden Death Prevention after Myocardial Infarction
Field, M. E., & Page, R. L. (2018) · New England Journal of Medicine · doi:10.1056/nejme1809832 · Cited by 11
Gandjbakhch, E., Rovani, M., Varnous, S., Maupain, C., Chastre, T., Waintraub, X., Pousset, F., Lebreton, G., Duthoit, G., Badenco, N., et al. (2016) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2016.02.005 · Cited by 10
Folino, A. F., Chiusso, F., Zanotto, G., Vaccari, D., GASPARINI, G., Megna, M., Marras, E., Mantovan, R., Vaglio, A., Boscolo, G., et al. (2011) · EP Europace · doi:10.1093/europace/eur154 · Cited by 10
Wearable cardioverter defibrillator in stress cardiomyopathy and cardiac arrest
Nascimento, F. O., Krishna, R. K., Hrachian, H. H., & Santana, O. (2013) · BMJ Case Reports · doi:10.1136/bcr-2013-009789 · Cited by 10
Biton, Y., Baman, J. R., & Polonsky, B. (2016) · Heart Failure Reviews · doi:10.1007/s10741-016-9542-y · Cited by 10
Duncker, D., Garcia, R., Bonderman, D., Casolo, G., Farkowski, M. M., Israel, C. W., & Marijon, É. (2025) · EP Europace · doi:10.1093/europace/euaf257 · Cited by 9
Kellnar, A., Fichtner, S., Sams, L. E., Stremmel, C., Estner, H., & Lackermair, K. (2023) · Patient Preference and Adherence · doi:10.2147/ppa.s400086 · Cited by 9
Casolo, G., Gulizia, M. M., Aschieri, D., Chinaglia, A., Corda, M., Nassiacos, D., Caico, S. I., Chimenti, C., Giaccardi, M., Gotti, E., et al. (2023) · European Heart Journal Supplements · doi:10.1093/eurheartjsupp/suad101 · Cited by 9
Jiang, X., Ming, W., & You, J. H. S. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14153 · Cited by 9
Over- and undersensing—pitfalls of arrhythmia detection with implantable devices and wearables
Sperzel, J., Hamm, C. W., & Hain, A. (2020) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-020-00710-x · Cited by 9
Wan, C., Szymkiewicz, S. J., & Klein, H. (2017) · American Heart Journal · doi:10.1016/j.ahj.2017.01.007 · Cited by 9
Self-citationTereshchenko, S. N., Жиров, И. В., Uskach, T. M., Saidova, M. A., Sp, G., Rimskaya, E. M., Николаевна, Н. С., Narusov, O. Y., Safiullina, A. A., Tereshchenko, A. S., et al. (2024) · Eurasian heart journal · doi:10.38109/2225-1685-2024-2-6-76 · Cited by 8
The wearable external cardiac defibrillator for cancer patients at risk for sudden cardiac death
Everitt, M. D., Verma, A., & Saarel, E. V. (2011) · Community Oncology · doi:10.1016/s1548-5315(12)70086-4 · Cited by 8
Update on Wearable Cardioverter Defibrillator: A Comprehensive Review of Literature
Alsamman, M., Prashad, A., Abdelmaseih, R., Khalid, T., & Prashad, R. (2022) · Cardiology Research · doi:10.14740/cr1387 · Cited by 8
Sp, G., Kostyukevich, M. V., Laiovich, L. I., Mironov, N. Y., Миронова, Н. А., Utsumueva, M. D., Khusyainova, D. R., Шлевков, Н. Б., Bazarov, B. C., Азизов, В. А., et al. (2022) · Eurasian heart journal · doi:10.38109/2225-1685-2022-4-6-67 · Cited by 10
Team-Based Care for Managing Cardiac Comorbidities in Heart Failure
Bellam, N., Kelkar, A. A., & Whellan, D. J. (2015) · Heart Failure Clinics · doi:10.1016/j.hfc.2015.03.005 · Cited by 8
Iliodromitis, K. E., Balogh, Z., Triposkiadis, F. K., Deftereos, S. G., Vrachatis, D. A., Bimpong‐Buta, N., Schiedat, F., & Bogossian, H. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1176710 · Cited by 7
Candida tropicalis defibrillator endocarditis: A case report and review of current literature
Bauer, B. K., Schulze, A. B., Löher, A., Reinke, F., & Eckardt, L. (2019) · Medical Mycology Case Reports · doi:10.1016/j.mmcr.2019.06.001 · Cited by 7
Aidelsburger, P., Seyed-Ghaemi, J., Guinin, C., & Fach, A. (2020) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462320000379 · Cited by 7
Hioki, H., Kozuma, K., Kobayashi, Y., Andò, K., Morino, Y., Kishihara, J., Ako, J., & Ikari, Y. (2021) · Cardiovascular Intervention and Therapeutics · doi:10.1007/s12928-021-00788-1 · Cited by 7
Multiparameter Monitoring with a Wearable Cardioverter Defibrillator
Rohrer, U., Manninger, M., Zirlik, A., & Scherr, D. (2021) · Sensors · doi:10.3390/s22010022 · Cited by 7
Abumayyaleh, M., Dreher, T. C., Rosenkaimer, S., Röger, S., Erath, J. W., Klein, N., Kovacs, B., Duru, F., Saguner, A. M., El‐Battrawy, I., et al. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15648 · Cited by 7
Dalia, A. A., Essandoh, M. K., Cronin, B., Hussain, N., Gerstein, N. S., & Schulman, P. M. (2019) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2019.01.004 · Cited by 7
Khan, H., & Leslie, S. J. (2019) · World Journal of Cardiology · doi:10.4330/wjc.v11.i3.103 · Cited by 7
Principles of External Defibrillators
Delgado, H. E., Toquero, J., Mitroi, C. D., Castro, V., & Fernandez, I. (2013) · InTech eBooks · doi:10.5772/52512 · Cited by 7
The Wearable Cardioverter-Defibrillator
Verdino, R. J. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.04.015 · Cited by 7
Gleva, M. J., Sullivan, J. L., Crawford, T., Walcott, G. P., Birgersdotter-Green, U. M., Branch, K. R., Doshi, R. N., Kivilaid, K., Brennan, K., Rowbotham, R. K., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0281340 · Cited by 6
Kontogiannis, V., Goromonzi, F., Both, B., Semrau, F., Branagan-Harris, M., Atkinson, J., Roberts, P. R., & Javanbakht, M. (2025) · PharmacoEconomics - Open · doi:10.1007/s41669-024-00553-z · Cited by 8
Kandzari, D. E., Perumal, R., & Bhatt, D. L. (2016) · Clinical Cardiology · doi:10.1002/clc.22544 · Cited by 6
Outcomes after asystole events occurring during wearable defibrillator-cardioverter use
Liang, J. J., Bianco, N. R., Muser, D., Enriquez, A. A., Santangeli, P., & D'Souza, B. A. (2018) · World Journal of Cardiology · doi:10.4330/wjc.v10.i4.21 · Cited by 6
Kovacs, B., Burri, H., Buehler, A., Reek, S., Sticherling, C., Schaer, B. A., Linka, A., Ammann, P., Müller, A. S., Dzemali, O., et al. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10173811 · Cited by 6
Dell’Era, G., Ziacchi, M., Prenna, E., Diemberger, I., Varalda, M., Martignani, C., Guerra, F., Biffi, M., & Occhetta, E. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13320 · Cited by 6
The wearable cardioverter-defibrillator vest: Indications and ongoing questions
Sandhu, U. G., Rajyaguru, C. P., Cheung, C. C., Morin, D. P., & Lee, B. K. (2019) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2019.05.005 · Cited by 6
Sinha, A. M., Bense, J., & Hohenforst‐Schmidt, W. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00898-5 · Cited by 6
Post-Shock Asystole in Patients Dying Out of Hospital While Wearing a Cardioverter Defibrillator
Berger, J. M., Sengupta, J. D., Bank, A. J., Casey, S. A., Sharkey, S. W., Stanberry, L. I., & Hauser, R. G. (2023) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2022.12.016 · Cited by 6
Sudden Death Risk in Syncope: The Role of The Implantable Cardioverter Defibrillator
Olshansky, B., & Sullivan, R. M. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.10.015 · Cited by 5
Wang, N. C., Piccini, J. P., & Gheorghiade, M. (2011) · Heart Failure Reviews · doi:10.1007/s10741-011-9243-5 · Cited by 5
Mountantonakis, S., & Hutchinson, M. D. (2011) · Current Heart Failure Reports · doi:10.1007/s11897-011-0069-1 · Cited by 5
Cardelli, L. S., Delbaere, Q., Massin, F., Granier, M., Casella, G., BARBATO, G., Dupasquier, V., Macia, J., Leclercq, F., Pasquié, J., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12154884 · Cited by 5
Use of the Wearable Cardioverter Defibrillator as a Bridge to Implantable Cardioverter Defibrillator
Weinstock, J. (2018) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2017.11.002 · Cited by 5
Rohrer, U., Manninger, M., Fiedler, L., Steinwender, C., Binder, R. K., Stuehlinger, M., Zirngast, B., Zweiker, D., Zirlik, A., & Scherr, D. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12155029 · Cited by 5
An appropriate shock of the wearable cardioverter‐defibrillator in an outpatient setting
Kishihara, J., Niwano, S., Nakamura, H. K., Igarashi, T., Ishizue, N., Fujiishi, T., Oikawa, J., Murakami, M., Fukaya, H., & Ako, J. (2015) · Journal of Arrhythmia · doi:10.1016/j.joa.2015.08.003 · Cited by 5
The Wearable Cardioverter-Defibrillator
Lee, B. K., & Olgin, J. E. (2016) · Circulation · doi:10.1161/circulationaha.116.024287 · Cited by 5
Ruth, R. A. J. P., Wagner, G. S., Hamad, M., Serroyen, J., & Gorgels, A. P. M. (2012) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2012.10.001 · Cited by 4
Fazzini, L., Marchetti, M. F., Perra, F., Biddau, M., Massazza, N., Nissardi, V., Agus, E., Demelas, R., & Montisci, R. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12144743 · Cited by 4
Dang, P. L., Lacour, P., Parwani, A. S., Baehr, F., Primeßnig, U., Schöppenthau, D., Dreger, H., Dagres, N., Hindricks, G., Boldt, L., et al. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13247768 · Cited by 4
A Fault-Tolerant Hardware Architecture for Robust Wearable Heart Rate Monitoring
Li, Q., Alemzadeh, H., Kalbarczyk, Z., & Iyer, R. K. (2015) · International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth.2015.259289 · Cited by 4
Einsatz des tragbaren Kardioverter-Defibrillators nach kardiochirurgischen Eingriffen
Bürger, H., Schmitt, J., Knaut, M., Eitz, T., Starck, C. T., Hakmi, S., Siebel, A., & Böning, A. (2018) · Zeitschrift für Herz- Thorax- und Gefäßchirurgie · doi:10.1007/s00398-018-0246-6 · Cited by 4
Mehta, N., Abdulsalam, N. M., Kouides, R. W., Ahmed, H., Atif, R., Shah, A. H., Taylor, S., Chuprun, D., Huang, D. T.-C., & Rao, M. C. (2019) · Clinical Cardiology · doi:10.1002/clc.23295 · Cited by 4
Wearable Cardioverter Defibrillator ― Initial Experience in the Outpatient Setting in Japan ―
Horiguchi, A., Kishihara, J., Niwano, S., Saito, D., Matsuura, G., Sato, T., Shirakawa, Y., Kobayashi, S., Arakawa, Y., Nishinarita, R., et al. (2020) · Circulation Reports · doi:10.1253/circrep.cr-20-0001 · Cited by 4
Andresen, H., Sasko, B. M., Patschan, D., Pagonas, N., & Ritter, O. (2021) · Journal of Medical Case Reports · doi:10.1186/s13256-021-02833-2 · Cited by 4
Berger, J. M., Sengupta, J. D., Bank, A. J., Casey, S. A., Witt, D., Sharkey, S. W., Stanberry, L. I., & Hauser, R. G. (2023) · Heart Rhythm · doi:10.1016/j.hrthm.2023.03.1604 · Cited by 4
Dreißig Jahre Defibrillatortherapie in Deutschland (1984–2014)
Trappe, H. (2014) · Der Kardiologe · doi:10.1007/s12181-014-0565-0 · Cited by 4
Sperzel, J., Staudacher, I., Göing, O., Stockburger, M. A., Meyer, T., Gonçalves, A. S. O., Sydow, H., Schoenfelder, T., & Amelung, V. E. (2018) · Medical Devices Evidence and Research · doi:10.2147/mder.s165770 · Cited by 4
Sears, S. F., Tripp, C., Huber, N. L., Khan, S., Nekkanti, R., Burch, A. E., & Pokorney, S. D. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14708 · Cited by 4
Use of the Wearable Cardioverter Defibrillator in High-Risk Populations
Lamichhane, M., Safadi, A. R., Surapaneni, P. K., Salehi, N., & Thakur, R. K. (2016) · Current Cardiology Reports · doi:10.1007/s11886-016-0746-5 · Cited by 4
Kron, J., & Ellenbogen, K. A. (2013) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.111.000098 · Cited by 4
Wearable cardioverter-defibrillator in patients with non-ischaemic cardiomyopathy: a meta-analysis
Providencia, R. A., Salih, A., Aidelsburger, P., Elayi, C. S., Narayanan, K., Piot, O., Casolo, G., Metra, M., Bovéda, S., Marijon, É., et al. (2026) · Heart · doi:10.1136/heartjnl-2025-326956 · Cited by 3
What’s the cardiac rhythm at the time of cardiac arrest? Disputed dogma or true fact?
Maury, P., Marimpouy, N., & Beneyto, M. M. (2024) · EP Europace · doi:10.1093/europace/euae299 · Cited by 3
Weth, C., Abuazab, H., Ewen, S., Ukena, C., Böhm, M., & Custodis, F. (2021) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-021-00816-w · Cited by 3
Experience with a Wearable Cardioverter-defibrillator in 436 Patients
Nägele, H., Groene, E. F., Stierle, D., KHAN, M., & Nägele, M. P. (2022) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2022.130104 · Cited by 3
Noordman, A. B. P., Rienstra, M., Blaauw, Y., Tieleman, R. G., & Maass, A. H. (2023) · Heart Rhythm O2 · doi:10.1016/j.hroo.2023.11.004 · Cited by 3
The Role of the Wearable Defibrillator in Heart Failure
Lenormand, T., Bodin, A., & Fauchier, L. (2024) · Current Heart Failure Reports · doi:10.1007/s11897-023-00641-x · Cited by 3
Keeping up to date: a current review of wearable cardioverter defibrillator use
Ashraf, S., Ilyas, S., Siddiqui, F., Ando, T., Shokr, M., Panaich, S., Briasoulis, Α., Afonso, L., & Khan, M. R. (2019) · Acta cardiologica. Supplementum · doi:10.1080/00015385.2019.1682337 · Cited by 3
The wearable cardioverter-defibrillator is not needed for most high-risk patients
Bhatt, A. G., & Mittal, S. (2020) · Heart Rhythm O2 · doi:10.1016/j.hroo.2020.07.002 · Cited by 3
Cooper, M., Berent, T., Auer, J., & Berent, R. (2020) · Wiener klinische Wochenschrift · doi:10.1007/s00508-020-01675-0 · Cited by 3
Dell’Era, G., Prenna, E., Ziacchi, M., Diemberger, I., Varalda, M., Guerra, F., Biffi, M., Occhetta, E., & Patti, G. (2021) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14355 · Cited by 3
When is a wearable defibrillator indicated?
Bodin, A., Bisson, A., & Fauchier, L. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.2019013 · Cited by 3
Review of developments in sensor technology for monitoring of health-related conditions
Rahman, A., Kafy, A., Kabir, J. F., Pranto, M. T. A., Akther, A., & Choudhury, I. A. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-96020-5.00062-5 · Cited by 3
Metadata
- Authors
- Chung, M. K., Szymkiewicz, S. J., Shao, M., Zishiri, E., Niebauer, M. J., Lindsay, B. D., & Tchou, P. J.
- Affiliations
- Cleveland Clinic (US)
- ZOLL Medical Corporation (United States) (US)
- Corresponding author
- Chung, Mina K.
- ORCID
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2010-07
- Volume
- 56
- Issue
- 3
- Pages
- 194-203
- ISSN
- 0735-1097 (ISSN-L)
- PMC
- PMC2962668
- OpenAlex
- W2159588890
- Cited by
- 297
- References
- 16
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 9 · 2023: 15 · 2022: 11 · 2021: 19 · 2020: 26 · 2019: 21 · 2018: 28 · 2017: 33 · 2016: 39 · 2015: 20 · 2014: 14 · 2013: 19 · 2012: 13
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Update notices
- erratum (2011-01-11)
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of the American College of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Medtronic, Inc.
- Boston Scientific
- St. Jude Medical
- Biotronik
- Medtronic
- National Institutes of Health (NIH R01 HL090620)
- ZOLL
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- wearable cardioverter defibrillator, medication adherence, sudden cardiac death prevention, ventricular tachycardia, ventricular fibrillation, implantable cardioverter-defibrillator, survival, asystole, sudden cardiac arrest, post-market registry
- MeSH terms
- Female, Humans, Male, Middle Aged, Patient Compliance, Ventricular Fibrillation, Death, Sudden, Cardiac, Tachycardia, Ventricular, Defibrillators
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review