Aggregate National Experience With the Wearable Cardioverter-Defibrillator
Open accessAbstract
Objectives The purpose of this study was to determine patient compliance and effectiveness of antiarrhythmic treatment by the wearable cardioverter-defibrillator (WCD).Background Effectiveness of the WCD for prevention of sudden death is dependent on event type, patient compliance, and appropriate management of ventricular tachycardia/ventricular fibrillation (VT/VF).Methods Compliance and events were recorded in a nationwide registry of post-market release WCDs. Survival, using the Social Security Death Index, was compared with survival in implantable cardioverter-defibrillator (ICD) patients.Results Of 3,569 patients wearing the WCD (age 59.3+/-14.7 years, duration 52.6+/-69.9 days), daily use was 19.9+/-4.7 h (>90% of the day) in 52% of patients. More days of use correlated with higher daily use (p<0.001). Eighty sustained VT/VF events occurred in 59 patients (1.7%). First-shock success was 76 of 76 (100%) for unconscious VT/VF and 79 of 80 (99%) for all VT/VF. Eight patients died after successful conversion of unconscious VT/VF (89.5% survival of VT/VF events). Asystole occurred in 23 (17 died), pulseless electrical activity in 2, and respiratory arrest in 1 (3 died), representing 24.5% of sudden cardiac arrests. During WCD use, 3,541 of 3,569 patients (99.2%) survived overall. Survival occurred in 72 of 80 (90%) VT/VF events and 78 of 106 (73.6%) for all events. Long-term mortality was not significantly different from first ICD implant patients but highest among patients with traditional ICD indications.Conclusions Compliance was satisfactory with 90% wear time in >50% of patients and low sudden death mortality during use. Survival was comparable to that of ICD patients. However, asystole was an important cause of mortality in sudden cardiac arrest events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“LiveVest showed comparable outcomes to implantable cardiac devices in a 3-year study (n = 3569) with acute event survival at 99.2% [38].”
From Wearables and the Medical Revolution (2018) · cites this paper as [38]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
The AVID Investigators (1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,221
Oss, J. M., Areba, W. O. Z., Ackson, W. J., Lein, H. E. K., Ilber, D. A. J. W., Annom, D. A. S. C., Ames, J. M., Aubert, P., Iggins, S. T. L. H., Rown, M. A. W. B., et al. (2002) · Cited by 2,026
Prophylactic use of an implantable cardioverter-defibrillator after acute myocardial infarction
Hohnloser, S. H., Kuck, K. H., Dorian, P., Roberts, R. S., Hampton, J. R., Hatala, R., Fain, E., Gent, M., & Connolly, S. J. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041489 · Cited by 1,519
Solomon, S. D., Zelenkofske, S., McMurray, J. J. V., Finn, P. V., Velazquez, E. J., Ertl, G., Harsanyi, A., Rouleau, J. L., Maggioni, A. P., Køber, L., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043938 · Cited by 800
Impact of Medication Therapy Discontinuation on Mortality After Myocardial Infarction
Ho, P. M., Spertus, J. A., Masoudi, F. A., Reid, K. J., Peterson, E. D., Magid, D. J., Krumholz, H. M., & Rumsfeld, J. S. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.17.1842 · Cited by 635
(2005) · New England Journal of Medicine · doi:10.1056/nejm200508183530725 · Cited by 601
Friedman, P. A., McClelland, R. L., Bamlet, W. R., Acosta, H., Kessler, D. J., Munger, T. M., Kavesh, N. G., Wood, M., Daoud, E. G., Massumi, A., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.594531 · Cited by 255
Flagged first, then by citations
Cited by
Sorted by citations
Items 201–296 of 296
How Should We Use the Wearable Cardioverter-Defibrillator in Japan?
Shimizu, A. (2014) · Circulation Journal · doi:10.1253/circj.cj-14-1188 · Cited by 3
Zei, P. C. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.07.022 · Cited by 3
Younis, A., & Goldenberg, I. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14403 · Cited by 3
Kikuchi, N., Shiga, T., Sugawara, Y., Suzuki, A., Minami, Y., Hattori, H., Shoda, M., Hagiwara, N., & Yamaguchi, J. (2024) · Journal of Arrhythmia · doi:10.1002/joa3.13158 · Cited by 2
Kazberuk, M., Pogorzelski, P., Kuźma, Ł., Kurasz, A., Róg‐Makal, M., Matys, U., Tokarewicz, J., Kralisz, P., & Dobrzycki, S. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13247686 · Cited by 2
Technological advances within digital medicine
Altibi, A. M. A., Alaref, S. J., & Khosravi, P. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820273-9.00001-4 · Cited by 2
The Subcutaneous Implantable Cardioverter Defibrillator
Mangels, D. R., & Frishman, W. H. (2016) · Cardiology in Review · doi:10.1097/crd.0000000000000099 · Cited by 2
Highlights of the Year in JACC 2010
DeMaria, A. N., Bax, J. J., Ben‐Yehuda, O., Feld, G. K., Greenberg, B., Hall, J. L., Hlatky, M. A., Lew, W. Y. W., Lima, J. A. C., Maisel, A. S., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.007 · Cited by 2
Quinine Syncope Diagnosed by Life Vest
Keriakos, R. A. N. (2015) · Clinical and Experimental Pharmacology · doi:10.4172/2161-1459.1000172 · Cited by 2
Angel, B., Overcash, J., Fischer, W., & Fontaine, J. M. (2016) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2016.09.002 · Cited by 2
Jagadish, P. S., Aziz, M., Chinta, V., & Khouzam, R. N. (2018) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2018.09.002 · Cited by 2
Kirolos, I., Jones, D. W., Hesterberg, K. G., Yarn, C., Khouzam, R. N., & Levine, Y. C. (2019) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-019-0746-z · Cited by 2
Cortesi, P. A., Botto, G. L., D’Angiolella, L. S., Scalone, L., Ponti, R. D., Boriani, G., & Mantovani, L. G. (2021) · Farmeconomia Health economics and therapeutic pathways · doi:10.7175/fe.v22i1s.1486 · Cited by 2
Novelties in the treatment of heart failure
Souček, F., & Novák, J. (2017) · Vnitřní lékařství · doi:10.36290/vnl.2017.053 · Cited by 2
Kojima, K., Kato, K., Fujii, Y., Okuyama, Y., Ohno, S., Ozawa, T., Horie, M., & Nakagawa, Y. (2022) · Internal Medicine · doi:10.2169/internalmedicine.8093-21 · Cited by 2
Magnusson, P. O., & LeQuang, J. A. (2020) · IntechOpen eBooks · doi:10.5772/intechopen.89286 · Cited by 2
Lai, M., Cheung, C. C., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lin, F., Hue, T. F., & Lee, B. K. (2022) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2022.10.009 · Cited by 2
A novel artificial intelligence based algorithm to reduce wearable cardioverter-defibrillator alarms
Arkles, J., Delaughter, C., & D'Souza, B. A. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01497-w · Cited by 2
Der tragbare Kardioverter-Defibrillator
Helms, T. M., Muller, A. M., Schwab, J. O., Bänsch, D., Karle, C. A., Klingenheben, T., Zugck, C., & Perings, C. A. (2015) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-015-0365-7 · Cited by 2
Gimmick or Godsend? The Wearable Cardioverter Defibrillator (WCD)
Simpson, C. S. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.02.034 · Cited by 2
Technological advances in cardiac pacing and defibrillation
Bun, S., Squara, F., Scarlatti, D., Théodore, G., Lațcu, D. G., Hasni, K., Benaïch, F. A., Allouche, E., Saoudi, N. C., & Ferrari, É. (2019) · Heart Vessels and Transplantation · doi:10.24969/hvt.2019.129 · Cited by 1
Costello, J. G., García, V. E., Moloney, E., Kontogiannis, V., Javanbakht, M., Goromonzi, F., Both, B., & Moreno, R. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1832880 · Cited by 1
Schrittmacherabhängigkeit und/oder rezidivierende ICD-Therapien
Möller, V., Hölschermann, F., Schau, T., & Butter, C. (2013) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-013-0281-7 · Cited by 1
Fan, W., & Khalighi, K. (2014) · Journal of Community Hospital Internal Medicine Perspectives · doi:10.3402/jchimp.v4.23909 · Cited by 1
Indications for a Wearable Cardioverter-Defibrillator
Dewland, T. A., Olgin, J. E., & Lee, B. K. (2011) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2011.05.001 · Cited by 1
Cardioverter defibrillator therapy in the primary and secondary prevention of sudden cardiac death
Becker, R., Zitron, E., Thomas, D., & Katus, H. A. (2012) · Cited by 1
Where has VFib gone? Why today's EMS crews see less ventricular fibrillation in the field.
Salvucci, A. (2010) · PubMed · doi:10.1016/s0197-2510(10)70300-4 · Cited by 1
Duncker, D., Bauersachs, J. K., & Veltmann, C. (2016) · Der Internist · doi:10.1007/s00108-016-0110-2 · Cited by 1
Boey, E., & Kojodjojo, P. (2018) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2018.090204 · Cited by 1
Efficacy of Wearable Cardioverter Defibrillators in 2 Children After Cardiopulmonary Arrest
Imamura, T., Sumitomo, N., Muraji, S., Osada, Y., Oyanagi, T., Kojima, T., Yoshiba, S., & Kobayashi, T. (2019) · Japanese Journal of Electrocardiology · doi:10.5105/jse.39.115 · Cited by 1
A missed opportunity for timely intervention to prevent a life-threatening event
Khan, M., Nangia, V., Bhatia, A., Mortada, M. E., Niazi, I. K., & Jahangir, A. (2022) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2022.01.011 · Cited by 1
(2023) · Cardiology Open Access · doi:10.33140/coa.08.01.04 · Cited by 1
EFFECTIVENESS OF WEARABLE DEFIBRILLATORS: SYSTEMATIC REVIEW AND QUALITY OF EVIDENCE
Uyei, J., & Braithwaite, R. S. (2014) · International Journal of Technology Assessment in Health Care · doi:10.1017/s026646231400004x · Cited by 1
ESC-Leitlinien 2015 zu ventrikulären Arrhythmien und zur Prävention des plötzlichen Herztodes
Fink, T., Kück, K., & Metzner, A. (2015) · Herz · doi:10.1007/s00059-015-4380-6 · Cited by 1
Wearable Cardioverter Defibrillators
Ferrick, A. M., Tian, D., Vudathaneni, V. K. P., Shevchuk, O. L., Ferrick, N. J., & Frishman, W. H. (2016) · Cardiology in Review · doi:10.1097/crd.0000000000000120 · Cited by 1
Reek, S. (2016) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000345 · Cited by 1
Doz., P., & Sperzel, J. (2016) · PubMed Central · doi:10.4022/jafib.1247 · Cited by 1
Perillo, L., & Sweeney, G. (2018) · Physical Therapy · doi:10.1093/ptj/pzy106 · Cited by 1
Duncker, D., & Veltmann, C. (2018) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-018-0601-z · Cited by 1
The Wearable Cardioverter-Defibrillator
Magnusson, P. O., Pergolizzi, J. V., & LeQuang, J. A. (2020) · IntechOpen eBooks · doi:10.5772/intechopen.90663 · Cited by 1
The wearable cardioverter-defibrillator is needed for most high-risk patients
Lee, B. K. (2020) · Heart Rhythm O2 · doi:10.1016/j.hroo.2020.07.001 · Cited by 1
Niwano, S., Abe, H., Takagi, M., Sekiguchi, Y., Iwasaki, Y., Kato, R., Kondo, Y., Kurita, T., Nitta, T., Nogami, A., et al. (2020) · Journal of Arrhythmia · doi:10.1002/joa3.12456 · Cited by 1
Active Ventricular Arrhythmias
de Luna, A. B. (2012) · Wiley eBooks · doi:10.1002/9781118392041.ch16 · Cited by 1
Wearable cardioverter defibrillator
Sperzel, J. (2016) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-016-0429-3 · Cited by 1
Long-term use of the wearable cardioverter-defibrillator: prolonging life or prolonging indecision?
ADELSTEIN, E. C. (2016) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-016-0212-8 · Cited by 1
Mitigating Post-Extraction Risk
Chung, M. K. (2016) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2016.10.015 · Cited by 1
Self-citationThe Wearable Cardioverter-Defibrillation
ADELSTEIN, E. C., & Saba, S. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.10.011 · Cited by 1
Wearable cardioverter defibrillators: dead on arrival or chance of survival?
Jagadish, P. S., & Khouzam, R. N. (2019) · Annals of Translational Medicine · doi:10.21037/atm.2019.07.04 · Cited by 1
Ettinger, S., Stanak, M., Szymański, P., Wild, C., Haček, R. T., Erčević, D., Grenković, R., Goetz, G., & Huić, M. (2019) · Medical Devices Evidence and Research · doi:10.2147/mder.s202581 · Cited by 1
Arrhythmias in Different Heart Diseases and Situations
de Luna, A. B. (2011) · Wiley eBooks · doi:10.1002/9781444391749.ch11
Gami, A. S., Hayes, D. L., Asirvatham, S. J., & Friedman, P. A. (2012) · Wiley eBooks · doi:10.1002/9781118483923.ch3
65-jähriger Patient mit tragbarem Kardioverter/Defibrillator nach akutem Herzinfarkt
Horlbeck, F., Nickenig, G., & Schwab, J. O. (2015) · Der Internist · doi:10.1007/s00108-015-3782-0
An under-utilized opportunity: The wearable cardioverter-defibrillator (WCD)
Jain, A. (2013) · Medical Practice and Reviews · doi:10.5897/mpr12.017
Randolph, T. C., & Piccini, J. P. (2013) · Heart Failure Clinics · doi:10.1016/j.hfc.2013.04.006
Indications for a Wearable Cardioverter
Dewland, T. A., Olgin, J. E., & Lee, B. K. (2011)
Implantable Cardioverter and Defibrillator Therapy
Ahmad, A., Garlitski, A., Link, M. S., Homoud, M. K., & Estes, N. A. M. (2013) · Springer eBooks · doi:10.1007/978-1-4471-4441-0_17
Wearable cardioverter–defibrillators in the spotlight
Mearns, B. M. (2010) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.132
The Latest Device for Prevention of Sudden Cardiac Death
Kohno, R., Oginosawa, Y., Hayashi, K., Ohe, H., Takahashi, M., & Abe, H. (2015) · Japanese Journal of Electrocardiology · doi:10.5105/jse.35.227
Barsheshet, A., Vamvouris, T., & Goldenberg, I. (2016) · Expert Review of Medical Devices · doi:10.1080/17434440.2016.1200969
Pérez‐Rodon, J. (2016) · TDX (Tesis Doctorals en Xarxa)
„Mismanagement“ oder „misunderstanding“?
Klein, H. (2016) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-016-0470-2
Prevention of Sudden Cardiac Death
Hussein, A. A., & Chung, M. K. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-42880-4.00022-4
Self-citationNishimura, T., Toyohara, K., Inai, K., Shinohara, T., Park, I. S., & Shoda, M. (2017) · Japanese Society of Pediatric Cardiology and Cardiac Surgery · doi:10.9794/jspccs.33.228
Der tragbare Defibrillator (WCD) – EHRA-Review
Perings, C. A. (2017) · Aktuelle Kardiologie · doi:10.1055/s-0043-110674
Honigberg, M. C., & Givertz, M. M. (2015)
Early Repolarization Syndrome and Implantable Cardioverter–Defibrillators
Kurita, T. (2017) · Springer eBooks · doi:10.1007/978-981-10-3379-7_8
Implantable and Wearable Defibrillator Therapy
Saba, S., & Estes, N. A. M. (2017) · Cardiovascular medicine · doi:10.1007/978-3-319-58000-5_11
Patienten mit einer tragbaren Defibrillatorweste („wearable cardioverter-defibrillator“, WCD)
Schlitt, A., Guha, M., Noutsias, M., Klein, H. H., & Klein, H. H. (2017) · Herz · doi:10.1007/s00059-017-4650-6
Yoshihiro, S., Sasaki, S., Toyama, Y., Nishizaki, K., Kinjo, T., Ishida, Y., Endo, T., Nishizaki, F., Itoh, T., Yokota, T., et al. (2018) · Hirosaki igaku · doi:10.32216/hirosakiigaku.68.2-4_135
Topics about new cardiac implantable devices
Kitano, T., Okajima, M., & Taniguchi, T. (2019) · Journal of the Japanese Society of Intensive Care Medicine · doi:10.3918/jsicm.26_373
Ichimura, K., Nishihara, M., Mukai, Y., Uwatoku, T., Tokuda, K., Akahoshi, T., Tsutsui, H., & Taguchi, T. (2019) · Journal of the Japanese Society of Intensive Care Medicine · doi:10.3918/jsicm.26_385
Who Should Receive a Wearable Defibrillator Vest at Hospital Discharge?
Kachur, S. M., & Morin, D. P. (2019) · Current Cardiology Reports · doi:10.1007/s11886-019-1215-8
Wearable Cardioverter-Defibrillators
ADELSTEIN, E. C., Wang, N. C., & Saba, S. (2019) · Springer eBooks · doi:10.1007/978-3-030-22882-8_3
Zaręba, W., Aktaş, M. K., & Lau, C. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-37804-8.00016-x
Analysis of Patients with LifeVest after Cardiac Surgery
Hajiyev, V., Erkenov, T., Smechowski, A., Just, S., Grimmig, O., & Fritzsche, D. (2020) · World Journal of Cardiovascular Surgery · doi:10.4236/wjcs.2020.105008
Kahn, P. A., Gruen, J., Thomas, A., Ahmad, T., & Desai, N. R. (2020) · American Heart Journal · doi:10.1016/j.ahj.2020.04.007
The past, present, and future of implantable cardioverter-defibrillators
Jones, R. P., & Berger, R. D. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-813704-8.00030-9
Wenn die Weste einige Nummern zu groß ist: Sinn und Unsinn der LifeVest bei Postinfarktpatienten
Bonnemeier, H. (2020) · Aktuelle Kardiologie · doi:10.1055/a-1289-7137
Clémenty, N., Bensaid, R., Bouteau, J. M., Fedida, J., Kiavue, Y., Socié, P., Ackermann, R., Goralski, M., Fauchier, L., Bernard, A. B., et al. (2021) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14244
Kancharla, K., Hayes, D. L., Asirvatham, S. J., & Friedman, P. A. (2021) · Wiley eBooks · doi:10.1002/9781119264002.ch3
de Luna, A. B., & FCCS, A. B. M. F. F. (2017) · doi:10.1002/9781119212782.app1
Active Ventricular Arrhythmias
de Luna, A. B. (2011) · doi:10.1002/9781444391749.ch5
Arrhythmias in Different Heart Diseases and Situations
de Luna, A. B., & FCCS, A. B. M. F. F. (2017) · Wiley eBooks · doi:10.1002/9781119212782.ch11
Wearable Treatment Device: Wearable Cardioverter Defibrillator (WCD)
亘, 松. (2017) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/jjmi.87.27
de Luna, A. B. (2011) · doi:10.1002/9781444391749.app1
Handling SCD risk in adult congenital heart disease: Should we InVEST in the WCD?
Narayanan, K. (2022) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2022.08.004
The wearable cardioverter-defibrillator in 2023: current evidence and clinical indications
Erath, J. W., & Wakili, R. (2023) · Cardiologia Hungarica · doi:10.26430/chungarica.2023.53.3.198
Advancements in automated external and wearable cardiac defibrillators
Aldaas, O. M., & Birgersdotter-Green, U. M. (2024) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000001189
Cardiovascular Implantable Electronic Devices and Dialysis Access
Saad, T. F., & Koplan, B. A. (2024) · Springer eBooks · doi:10.1007/978-3-031-70514-4_52
Reynolds, J. C., Oostema, J. A., Sierzant, C., & Sherwin, K. (2025) · Cureus · doi:10.7759/cureus.85296
Should LifeVest Be Worn During Shower: A Case Report
Lam, V. S., Huynh, K. H., & Tran, P. (2025) · Cureus · doi:10.7759/cureus.88663
Guglieri, M., Lenormand, T., Bodin, A., Bisson, A., & Fauchier, L. (2025) · Current Cardiology Reports · doi:10.1007/s11886-025-02321-9
The ‘CIED Team’ Approach to Device-Related Complications
Mazzotta, R., Cosco, L., Fedeli, F., Ricciardi, G., Bambagioni, G., Bernini, M., Scanferla, R., Pieragnoli, P., Perrotta, L., & Checchi, L. (2026) · JACC Case Reports · doi:10.1016/j.jaccas.2026.108976
Matteucci, A., Bonanni, M., Mariani, M. V., Sgarra, L., Nesti, L., Pierucci, N., Fusco, S. A. D., Fedele, S., Nardi, F., & Colivicchi, F. (2026) · Diagnostics · doi:10.3390/diagnostics16182990
Sensi, F. D., Baratta, P., & Limbruno, U. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15218358
Metadata
- Authors
- Chung, M. K., Szymkiewicz, S. J., Shao, M., Zishiri, E., Niebauer, M. J., Lindsay, B. D., & Tchou, P. J.
- Affiliations
- Cleveland Clinic (US)
- ZOLL Medical Corporation (United States) (US)
- Corresponding author
- Chung, Mina K.
- ORCID
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2010-07
- Volume
- 56
- Issue
- 3
- Pages
- 194-203
- ISSN
- 0735-1097 (ISSN-L)
- PMC
- PMC2962668
- OpenAlex
- W2159588890
- Cited by
- 297
- References
- 16
- Citations by year
- 2026: 5 · 2025: 6 · 2024: 9 · 2023: 15 · 2022: 11 · 2021: 19 · 2020: 26 · 2019: 21 · 2018: 28 · 2017: 33 · 2016: 39 · 2015: 20 · 2014: 14 · 2013: 19 · 2012: 13
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Update notices
- erratum (2011-01-11)
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of the American College of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Medtronic, Inc.
- Boston Scientific
- St. Jude Medical
- Biotronik
- Medtronic
- National Institutes of Health (NIH R01 HL090620)
- ZOLL
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- wearable cardioverter defibrillator, medication adherence, sudden cardiac death prevention, ventricular tachycardia, ventricular fibrillation, implantable cardioverter-defibrillator, survival, asystole, sudden cardiac arrest, post-market registry
- MeSH terms
- Female, Humans, Male, Middle Aged, Patient Compliance, Ventricular Fibrillation, Death, Sudden, Cardiac, Tachycardia, Ventricular, Defibrillators
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review