The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Minimally-Invasive Implantation of Living Tissue Engineered Heart Valves
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isolation of Putative Progenitor Endothelial Cells for Angiogenesis
Asahara, T., Murohara, T., Sullivan, A., Silver, M., van der Zee, R., Li, T., Witzenbichler, B., Schatteman, G., & Isner, J. M. (1997) · Science · doi:10.1126/science.275.5302.964 · Cited by 8,725
The incidence of congenital heart disease.
Hoffman, J. I. E., & Kaplan, S. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01886-7 · Cited by 6,099
Cited by
Hockaday, L. A., Kang, K. H., Colangelo, N. W., Cheung, P. Y. C., Duan, B., Malone, E., Wu, J., Girardi, L. N., Bonassar, L. J., Lipson, H., et al. (2012) · Biofabrication · doi:10.1088/1758-5082/4/3/035005 · Cited by 683
3D bioprinting using stem cells
Ong, C. S., Yesantharao, P., Huang, C. Y., Mattson, G., Boktor, J., Fukunishi, T., Zhang, H., & Hibino, N. (2018) · Pediatric Research · doi:10.1038/pr.2017.252 · Cited by 265
Substrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Self-citationNext-generation tissue-engineered heart valves with repair, remodelling and regeneration capacity
Fioretta, E. S., Motta, S. E., Lintas, V., Loerakker, S., Parker, K. K., Baaijens, F. P. T., Falk, V., Hoerstrup, S. P., & Emmert, M. Y. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-0422-8 · Cited by 262
Self-citationMabry, K. M., Payne, S. Z., & Anseth, K. S. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2015.09.035 · Cited by 124
Metadata
- Authors
- Schmidt, D., Dijkman, P. E., Driessen-Mol, A., Stenger, R., Mariani, C., Puolakka, A., Rissanen, M., Deichmann, T., Odermatt, B., Weber, B., Emmert, M. Y., Zund, G., Baaijens, F. P. T., & Hoerstrup, S. P.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 56
- Issue
- 6
- Pages
- 510-520
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W1522824862
- Cited by
- 221
- References
- 2
- FWCI
- 24.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Minimally-Invasive Implantation of Living Tissue Engineered Heart Valves. https://app.cochat.ai/papers/10.1016/j.jacc.2010.04.024
- The paper
- Schmidt, D., Dijkman, P. E., Driessen-Mol, A., Stenger, R., Mariani, C., Puolakka, A., Rissanen, M., Deichmann, T., Odermatt, B., Weber, B., Emmert, M. Y., Zund, G., Baaijens, F. P. T., & Hoerstrup, S. P. (2010). Minimally-Invasive Implantation of Living Tissue Engineered Heart Valves. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2010.04.024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.