Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 185

The DOI matches its Crossref record.

Cumulative Exposure to Ionizing Radiation From Diagnostic and Therapeutic Cardiac Imaging Procedures

Open access
Chen, Jersey, Einstein, Andrew J., Fazel, Reza, Krumholz, Harlan M., Wang, Yongfei, Ross, Joseph S., Ting, Henry H., Shah, Nilay D., Nasir, Khurram, Nallamothu, Brahmajee K. · 2010 · Journal of the American College of Cardiology

Abstract

Objectives To describe radiation exposure from cardiac imaging procedures over time in a general population. Background Cardiac imaging procedures frequently expose patients to ionizing radiation, but their contribution to effective doses of radiation in the general population is unknown. Methods We used administrative claims to identify cardiac imaging procedures performed from 2005-2007 in 952,420 non-elderly insured adults in 5 U.S. healthcare markets. We estimated 3-year cumulative effective doses of radiation in millisieverts (mSv) from these procedures We then calculated population-based annual rates of radiation exposure to effective doses ≤3 mSv/year (background level of radiation from natural sources), >3-20 mSv/year, or >20 mSv/year (upper annual limit for occupational exposure averaged over 5 years). Results 90,121 (9.5%) individuals underwent at least one cardiac imaging procedure using radiation. Among patients who underwent ≥1 cardiac imaging procedure, the mean cumulative effective dose over 3 years was 16.4 mSv (range 1.5-189.5 mSv). Myocardial perfusion imaging accounted for 74% of the cumulative effective dose. Overall, 47.8% of cardiac imaging procedures were performed in physician offices; this proportion was higher for myocardial perfusion imaging (74.8%) and cardiac CT studies (76.5%). The annual population-based rate of receiving an effective dose of >3-20 mSv/year was 89.0 per 1000; and 3.3 per 1000 for cumulative doses >20 mSv/year. Annual effective doses increased with age and were generally higher among men. Conclusions Cardiac imaging procedures lead to substantial radiation exposure and effective doses for many patients in the United States.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2010.05.014

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
Chen, J., Einstein, A. J., Fazel, R., Krumholz, H. M., Wang, Y., Ross, J. S., Ting, H. H., Shah, N. D., Nasir, K., & Nallamothu, B. K.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2010-08
Volume
56
Issue
9
Pages
702-711
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1518916998
Cited by
185
References
0
FWCI
13.98
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cumulative Exposure to Ionizing Radiation From Diagnostic and Therapeutic Cardiac Imaging Procedures. https://app.cochat.ai/papers/10.1016/j.jacc.2010.05.014
The paper
Chen, J., Einstein, A. J., Fazel, R., Krumholz, H. M., Wang, Y., Ross, J. S., Ting, H. H., Shah, N. D., Nasir, K., & Nallamothu, B. K. (2010). Cumulative Exposure to Ionizing Radiation From Diagnostic and Therapeutic Cardiac Imaging Procedures. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2010.05.014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.