CoChat

Incremental Value of Cardiac Magnetic Resonance Imaging in Arrhythmic Risk Stratification of Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy–Associated Desmosomal Mutation Carriers

Open access
te Riele, Anneline S.J.M., Bhonsale, Aditya, James, Cynthia A., Rastegar, Neda, Murray, Brittney, Burt, Jeremy R., Tichnell, Crystal, Madhavan, Srinivasa, Judge, Daniel P., Bluemke, David A., Zimmerman, Stefan L., Kamel, Ihab R., Calkins, Hugh, Tandri, Harikrishna · 2013 · Journal of the American College of Cardiology
Cited by 134

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objectives To identify the incremental value and optimal role of Cardiac Magnetic Resonance (CMR) imaging in arrhythmic risk stratification of Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy (ARVD/C) associated desmosomal mutation carriers without a prior history of sustained ventricular arrhythmia. Background Risk stratification of ARVD/C mutation carriers is challenging. Methods We included 69 patients (age 27.0 ± 15.3 years, 42% male) harboring ARVD/C associated pathogenic mutations (83% PKP-2) without prior sustained ventricular arrhythmias. Electrocardiography (ECG) and 24-hours Holter monitoring closest to presentation were analyzed for electrical abnormalities as per revised Task Force Criteria. CMR studies were done to identify abnormal cardiac structure and function according to the revised Task Force Criteria. Results Overall, 42 (61%) patients presented with electrical abnormalities based on their ECG and Holter monitor, of whom 20 (48%) had an abnormal CMR. Only 1 (4%) of 27 patients without electrical abnormalities at initial evaluation had an abnormal CMR. Over a mean follow-up of 5.8 ± 4.4 years, 11 (16%) patients experienced a sustained ventricular arrhythmia, exclusively in patients with both electrical abnormalities (ECG and/or Holter) and abnormal CMR. Conclusion Our results suggest that electrical abnormalities on ECG and Holter monitoring precede detectable structural abnormalities in ARVD/C mutation carriers. Therefore, evaluation of cardiac structure and function using CMR is probably not necessary in the absence of baseline electrical abnormalities. Among ARVD/C mutation carriers, the presence of both electrical and CMR abnormalities identifies patients at high risk of events and thus patients who might benefit from prophylactic implantable cardioverter-defibrillator implantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2012.11.087

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
te Riele, A. S. J. M., Bhonsale, A., James, C. A., Rastegar, N., Murray, B., Burt, J. R., Tichnell, C., Madhavan, S., Judge, D. P., Bluemke, D. A., Zimmerman, S. L., Kamel, I. R., Calkins, H., & Tandri, H.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2013-11
Volume
62
Issue
19
Pages
1761-1769
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1968303482
Cited by
134
References
3
FWCI
11.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.