Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 195

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Noninvasive Electrocardiographic Mapping to Improve Patient Selection for Cardiac Resynchronization Therapy

Open access
Ploux, Sylvain, Lumens, Joost, Whinnett, Zachary, Montaudon, Michel, Strom, Maria, Ramanathan, Charu, Derval, Nicolas, Zemmoura, Adlane, Denis, Arnaud, De Guillebon, Maxime, Shah, Ashok, Hocini, Mélèze, Jaïs, Pierre, Ritter, Philippe, Haïssaguerre, Michel, Wilkoff, Bruce L., Bordachar, Pierre · 2013 · Journal of the American College of Cardiology

Abstract

OBJECTIVES This study sought to investigate whether noninvasive electrocardiographic activation mapping is a useful method for predicting response to cardiac resynchronization therapy (CRT). BACKGROUND One third of the patients appear not to respond to CRT when they are selected according to QRS duration. METHODS We performed electrocardiographic activation mapping in 33 consecutive CRT candidates (QRS duration ≥120 ms). In 18 patients, the 12-lead electrocardiographic morphology was left bundle branch block (LBBB), and in 15, it was nonspecific intraventricular conduction disturbance (NICD). Three indexes of electrical dyssynchrony were derived from intrinsic maps: right and left ventricular total activation times and ventricular electrical uncoupling (VEU) (difference between the left ventricular [LV] and right ventricular mean activation times). We assessed the ability of these parameters to predict response, measured using a clinical composite score, after 6 months of CRT. RESULTS Electrocardiographic maps revealed homogeneous patterns of activation and consistently greater VEU and LV total activation time (LVTAT) in patients with LBBB compared with heterogeneous activation sequences and shorter VEU and LVTAT in NICD patients (VEU: 75 ± 12 ms vs. 40 ± 22 ms; p < 0.001; LVTAT: 115 ± 21 ms vs. 91 ± 34 ms; p = 0.03). LBBB and NICD patients had similar right ventricular total activation times (62 ± 30 ms vs. 58 ± 26 ms; p = 0.7). The area under the receiver-operating characteristic curve indicated that VEU (area under the curve [AUC]: 0.88) was significantly superior to QRS duration (AUC: 0.73) and LVTAT (AUC: 0.72) for predicting CRT response (p < 0.05). With a 50-ms cutoff value, VEU identified CRT responders with 90% sensitivity and 82% specificity whether LBBB was present or not. CONCLUSIONS Ventricular electrical uncoupling measured by electrocardiographic mapping predicted clinical CRT response better than QRS duration or the presence of LBBB.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2013.01.093

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events

    Moss, A. J., Hall, W. J., Cannom, D. S., Klein, H., Brown, M. W., Daubert, J. P., Estes, N. A. M., Foster, E., Greenberg, H., Higgins, S. L., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0906431 · Cited by 3,157

  • Cardiac-Resynchronization Therapy for Mild-to-Moderate Heart Failure

    Tang, A. S. L., Wells, G. A., Talajic, M., Arnold, M. O., Sheldon, R., Connolly, S., Hohnloser, S. H., Nichol, G., Birnie, D. H., Sapp, J. L., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1009540 · Cited by 1,859 · cited 1×

    “Given the high proportion of patients presenting with NICD (approximately one third of the recent RAFT [Resynchronization– Defibrillation for Ambulatory Heart Failure Trial] and REVERSE [Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction] trials) and/or QRS duration <150 ms (40% of the Euro…”
    Background

Cited by

See all 195

Metadata

Authors
Ploux, S., Lumens, J., Whinnett, Z., Montaudon, M., Strom, M., Ramanathan, C., Derval, N., Zemmoura, A., Denis, A., De Guillebon, M., Shah, A., Hocini, M., Jaïs, P., Ritter, P., Haïssaguerre, M., Wilkoff, B. L., & Bordachar, P.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2013-06
Volume
61
Issue
24
Pages
2435-2443
ISSN
0735-1097 (ISSN-L)
OpenAlex
W117247478
Cited by
195
References
2
FWCI
12.29
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.