The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Direct or Coincidental Elimination of Stable Rotors or Focal Sources May Explain Successful Atrial Fibrillation Ablation
Open accessAbstract
Objective We hypothesized that ablation of recently described stable AF sources, either directly by Focal Impulse and Rotor Modulation (FIRM) or coincidentally when anatomical ablation passes through AF sources, may explain long term freedom of AF. Background It is unclear why conventional anatomical AF ablation can be very effective in some patients yet ineffective in others with similar profiles. Methods The CONFIRM trial prospectively revealed stable AF rotors or focal sources in 98/101 subjects with AF at 107 consecutive ablation cases. In 1:2 fashion, subjects received targeted source ablation (FIRM) then conventional ablation, or conventional ablation alone. We determined if ablation lesions on electroanatomic maps passed through AF sources on FIRM maps. Results Subjects who completed followup (n=94, 71.2% persistent AF) each showed 2.3±1.1 concurrent AF rotors or focal sources, that lay near pulmonary veins (22.8%), left atrial roof (16.0%), and elsewhere in left (28.2%) and right (33.0%) atria. AF sources were ablated directly in 100% FIRM cases and coincidentally (e.g. left atrial roof) in 45% conventional cases (p<0.05). During 273 days (median, IQR 138–636) after 1 procedure, AF was absent in 80.3% of patients if sources were ablated but recurred in 81.8% of patients if sources were missed (p<0.001). Freedom from AF was highest if all sources were ablated, intermediate if some sources were ablated, and lowest if no sources were ablated (p<0.001). CONCLUSIONS Elimination of stable AF rotors and focal sources may explain freedom from AF after diverse approaches to ablation. Patient-specific AF source distributions are consistent with the reported success of specific anatomical lesion sets, and of widespread ablation. These results support targeting AF sources to reduce unnecessary ablation, and motivate studies on FIRM-only ablation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rhythm control versus rate control for atrial fibrillation and heart failure
Roy, D., Talajic, M., Nattel, S., Wyse, D. G., Dorian, P., Lee, K. L., Bourassa, M. G., Arnold, J. M. O., Buxton, A. E., Camm, A. J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0708789 · Cited by 1,585
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
Atrial Remodeling and Atrial Fibrillation: Mechanisms and Implications
Nattel, S., Burstein, B., & Dobrev, D. (2008) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.107.754564 · Cited by 1,124
Lenient versus strict rate control in patients with atrial fibrillation
Van Gelder, I. C., Groenveld, H. F., Crijns, H. J. G. M., Tuininga, Y. S., Tijssen, J. G. P., Alings, A. M., Hillege, H. L., Bergsma-Kadijk, J. A., Cornel, J. H., Kamp, O., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1001337 · Cited by 1,033 · cited 1×
“Atrial fibrillation (AF) is a major cause of morbidity and mortality, for which pharmacologic approaches for rate (1) or hythm control (2) remain suboptimal.”
Radiofrequency ablation as initial therapy in paroxysmal atrial fibrillation
Cosedis Nielsen, J., Johannessen, A., Raatikainen, P., Hindricks, G., Walfridsson, H., Kongstad, O., Pehrson, S., Englund, A., Hartikainen, J., Mortensen, L. S., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1113566 · Cited by 720
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Hansen, B. J., Zhao, J., Csepe, T. A., Moore, B. T., Li, N., Jayne, L. A., Kalyanasundaram, A., Lim, P., Bratasz, A., Powell, K. A., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv233 · Cited by 413
Narayan, S. M., Baykaner, T., Clopton, P., Schricker, A., Lalani, G. G., Krummen, D. E., Shivkumar, K., & Miller, J. M. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.543 · Cited by 368
Self-citation
Metadata
- Authors
- Narayan, S. M., Krummen, D. E., Clopton, P., Shivkumar, K., & Miller, J. M.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 62
- Issue
- 2
- Pages
- 138-147
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W65492245
- Cited by
- 218
- References
- 6
- FWCI
- 22.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.