CoChat

Appropriateness of Primary Prevention Implantable Cardioverter-Defibrillators at the Time of Generator Replacement

Open access
Kini, Vinay, Soufi, Mohamad Khaled, Deo, Rajat, Epstein, Andrew E., Bala, Rupa, Riley, Michael, Groeneveld, Peter W., Shalaby, Alaa, Dixit, Sanjay · 2014 · Journal of the American College of Cardiology
Cited by 134

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objectives This study sought to determine how often patients with primary prevention implantable cardioverter-defibrillators (ICDs) meet guideline-derived indications at the time of generator replacement. Background Professional societies have developed guideline criteria for the appropriate implantation of an ICD for the primary prevention of sudden cardiac death. It is unknown whether patients continue to meet criteria when their devices need replacement for battery depletion. Methods We performed a retrospective chart review of patients undergoing replacement of primary prevention ICDs at 2 tertiary Veterans Affairs Medical Centers. Indications for continued ICD therapy at the time of generator replacement included a left ventricular ejection fraction (LVEF) ≤35% or receipt of appropriate device therapy. Results In our cohort of 231 patients, 59 (26%) no longer met guideline-driven indications for an ICD at the time of generator replacement. An additional 79 patients (34%) had not received any appropriate ICD therapies and had not undergone reassessment of their LVEF. Patients with an initial LVEF of 30% to 35% were less likely to meet indications for ICD therapy at the time of replacement (odds ratio: 0.52; 95% confidence interval: 0.30 to 0.88; p = 0.01). Patients without ICD indications subsequently received appropriate ICD therapies at a significantly lower rate than patients with indications (2.8% vs. 10.7% annually, p < 0.001). If ICD generator explantations were performed instead of replacements in the patients without ICD indications, the cost savings would be $1.6 million. Conclusions Approximately 25% of patients who receive primary prevention ICDs may no longer meet guideline indications for ICD use at the time of generator replacement, and these patients receive subsequent ICD therapies at a significantly lower rate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2014.03.025

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 134

Metadata

Authors
Kini, V., Soufi, M. K., Deo, R., Epstein, A. E., Bala, R., Riley, M., Groeneveld, P. W., Shalaby, A., & Dixit, S.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2014-06
Volume
63
Issue
22
Pages
2388-2394
ISSN
0735-1097 (ISSN-L)
OpenAlex
W191566822
Cited by
134
References
3
FWCI
12.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.