Early Safety and Efficacy of Percutaneous Left Atrial Appendage Suture Ligation

Open access
Price, Matthew J., Gibson, Douglas N., Yakubov, Steven J., Schultz, Jason C., Di Biase, Luigi, Natale, Andrea, Burkhardt, J. David, Pershad, Ashish, Byrne, Timothy J., Gidney, Brett, Aragon, Joseph R., Goldstein, Jeffrey, Moulton, Kriegh, Patel, Taral, Knight, Bradley, Lin, Albert C., Valderrábano, Miguel · 2014 · Journal of the American College of Cardiology

Abstract

BACKGROUND Transcatheter left atrial appendage (LAA) ligation may represent an alternative to oral anticoagulation for stroke prevention in atrial fibrillation.. OBJECTIVES This study sought to assess the early safety and efficacy of transcatheter ligation of the LAA for stroke prevention in atrial fibrillation.. METHODS This was a retrospective, multicenter study of consecutive patients undergoing LAA ligation with the Lariat device at 8 U.S. sites. The primary endpoint was procedural success, defined as device success (suture deployment and <5 mm leak by post-procedure transesophageal echocardiography), and no major complication at discharge (death, myocardial infarction, stroke, Bleeding Academic Research Consortium bleeding type 3 or greater, or cardiac surgery). Post-discharge management was per operator discretion. RESULTS A total of 154 patients were enrolled. Median CHADS2 score (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke, transient ischemic attack, or thromboembolism [doubled]) was 3 (interquartile range: 2 to 4). Device success was 94%, and procedural success was 86%. A major complication occurred in 15 patients (9.7%). There were 14 major bleeds (9.1%), driven by the need for transfusion (4.5%). Significant pericardial effusion occurred in 16 patients (10.4%). Follow-up was available in 134 patients at a median of 112 days (interquartile range: 50 to 270 days): Death, myocardial infarction, or stroke occurred in 4 patients (2.9%). Among 63 patients with acute closure and transesophageal echocardiography follow-up, there were 3 thrombi (4.8%) and 13 (20%) with residual leak. CONCLUSIONS In this initial multicenter experience of LAA ligation with the Lariat device, the rate of acute closure was high, but procedural success was limited by bleeding. A prospective randomized trial is required to adequately define clinical efficacy, optimal post-procedure medical therapy, and the effect of operator experience on procedural safety.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2014.03.057

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 211

Metadata

Authors
Price, M. J., Gibson, D. N., Yakubov, S. J., Schultz, J. C., Di Biase, L., Natale, A., Burkhardt, J. D., Pershad, A., Byrne, T. J., Gidney, B., Aragon, J. R., Goldstein, J., Moulton, K., Patel, T., Knight, B., Lin, A. C., & Valderrábano, M.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2014-08
Volume
64
Issue
6
Pages
565-572
ISSN
0735-1097 (ISSN-L)
OpenAlex
W117625412
Cited by
211
References
8
FWCI
26.11
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.