Clinical Classifications of Atrial Fibrillation Poorly Reflect Its Temporal Persistence
Open accessAbstract
Objectives This study aimed to identify how accurately the current clinical atrial fibrillation (AF) classifications reflect its temporal persistence.Background Clinical classification of AF is employed to communicate its persistence, to select appropriate therapies, and as inclusion criterion for clinical trials.Methods Cardiac rhythm histories of 1,195 patients (age 73.0 ± 10.1 years, follow-up: 349 ± 40 days) with implantable devices were reconstructed and analyzed. Patients were classified as having paroxysmal or persistent AF by physicians at baseline in accordance with current guidelines. AF burden, measured as the proportion of time spent in AF, was obtained from the device. Additionally we evaluated the agreement between clinical and device-derived AF classifications.Results Patients within the same clinical class were highly heterogeneous with regards to AF temporal persistence. Agreement between the clinical AF classification and the objective device-derived assessments of AF temporal persistence was poor (Cohen's kappa: 0.12 [95% CI: 0.05 to 0.18]). Patient characteristics influenced the clinical decision to classify AF as paroxysmal or persistent. Higher ejection fraction (odds ratio: 0.97/per unit [95% CI: 0.95 to 0.98/per unit]; p < 0.0001) and presence of coronary artery disease (odds ratio: 0.53 [95% CI: 0.32 to 0.88]; p = 0.01) were independently associated with a lower probability of being classified as persistent AF for the same AF burden level.Conclusions The currently used clinical AF classifications poorly reflect AF temporal persistence. Patient characteristics significantly influence the physician's classification of AF. Patients classified in identical clinical categories may be inherently heterogeneous with regard to AF temporal persistence. Further study is required to determine if patient selection on the basis of objective criteria derived from rigorous AF monitoring can improve reported outcomes and better identify responders and non-responders to treatments. (OMNI Study-Assessing Therapies in Medtronic Pacemaker, Defibrillator, and Cardiac Resynchronization Therapy Devices; NCT00277524; TRENDS: A Prospective Study of the Clinical Significance of Atrial Arrhythmias Detected by Implanted Device Diagnostics; NCT00279981).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Reliance on symptoms alone (by patient or physician) may be misleading-both over and underestimating the presence of AF (Charitos et al., 2014).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Charitos et al., 2014
Experimental — accuracy not yet measuredIn the citing paper
“Clinically determined AF patterns do not correspond well to the AF burden measured by long-term ECG monitoring.163”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [163]
In the citing paper
“Asymptomatic AF is often undiagnosed41 and is likely underdiagnosed in this study as well.”
From Twelve-single nucleotide polymorphism genetic risk score identifies individuals at increased risk for future atrial fibrillation and stroke (2014) · cites this paper as [41]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2000) · doi:10.32614/r.manuals · Cited by 355,893
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H. G., Cigarroa, J. E., Cleveland, J. C., CONTI, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,145
Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Kirchhof, P. F., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Gelder, I. C. V., Al‐Attar, N., Hindricks, G., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq278 · Cited by 5,954
Atrial Fibrillation Begets Atrial Fibrillation
WIJFFELS, M. C. E. F., Kirchhof, C. J. H. J., Dorland, R., & Allessie, M. A. (1995) · Circulation · doi:10.1161/01.cir.92.7.1954 · Cited by 3,500
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial Fibrillation
Packer, D. L., Kowal, R. C., Wheelan, K. R., Irwin, J. M., Champagne, J., Guerra, P. G., Dubuc, M., Reddy, V. Y., Nelson, L., Holcomb, R. G., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.064 · Cited by 919
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879 · cited 1×
“For the device-derived AF classification, we used the following definitions: no AF: no day with >5 min of AF (11,13,14); paroxysmal AF: at least 1 day with >5 min of AF but <7 consecutive days with >23 h of AF; persistent AF: at least 7 consecutive days with >23 h of AF (15,16); permanent AF: All days with >23 h of AF…”
MethodSelf-citationRadiofrequency ablation as initial therapy in paroxysmal atrial fibrillation
Cosedis Nielsen, J., Johannessen, A., Raatikainen, P., Hindricks, G., Walfridsson, H., Kongstad, O., Pehrson, S., Englund, A., Hartikainen, J., Mortensen, L. S., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1113566 · Cited by 720
Page, R. L., Wilkinson, W. E., Clair, W. K., McCarthy, E. A., & Pritchett, E. L. (1994) · Circulation · doi:10.1161/01.cir.89.1.224 · Cited by 627 · cited 1×
“It is well established that these brief monitoring snapshots do not accurately capture the true arrhythmia status (5,6,29) and that relying on patient symptoms can lead to both under-reporting and over-reporting of AF (3,4,30).”
BackgroundMinimizing Ventricular Pacing to Reduce Atrial Fibrillation in Sinus-Node Disease
Sweeney, M. O., Bank, A. J., Nsah, E., Koullick, M., Zeng, Q. C., Hettrick, D. A., Sheldon, T., & Lamas, G. A. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071880 · Cited by 518
Hindricks, G., Pokushalov, E., Urban, L., Taborsky, M., Kuck, K.-H., Lebedev, D., Rieger, G., & Pürerfellner, H. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.877852 · Cited by 422
Self-citationBOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
(2006) · Circulation · doi:10.1161/circ.114.4.257 · Cited by 364
Daoud, E. G., Glotzer, T. V., Wyse, D. G., Ezekowitz, M. D., Hilker, C., Koehler, J., & Ziegler, P. D. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.04.022 · Cited by 326
Comparison of continuous versus intermittent monitoring of atrial arrhythmias
Ziegler, P., Koehler, J. L., & Mehra, R. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.07.030 · Cited by 281
Self-citationA Detector for a Chronic Implantable Atrial Tachyarrhythmia Monitor
Sarkar, S. C., Ritscher, D. E., & Mehra, R. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.903707 · Cited by 226
Relationship between atrial tachyarrhythmias and symptoms
Strickberger, S. A., Ip, J. E., Saksena, S. V., Curry, K., Bahnson, T. D., & Ziegler, P. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2004.10.042 · Cited by 198
Self-citationCharitos, E. I., Stierle, U., Ziegler, P. D., Baldewig, M., Robinson, D. R., Sievers, H.-H., & Hanke, T. (2012) · Circulation · doi:10.1161/circulationaha.112.098079 · Cited by 196
Self-citationAngiotensin II-antagonist in paroxysmal atrial fibrillation (ANTIPAF) trial
Goette, A., Schön, N., Kirchhof, P., Breithardt, G., Fetsch, T., Häusler, K. G., Klein, H. U., Steinbeck, G., Wegscheider, K., & Meinertz, T. (2012) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.111.965178 · Cited by 187
Pokushalov, E. A., Romanov, A., Katritsis, D. G., Николаевич, А. С., Shirokova, N., Karaskov, A., Mittal, S., & Steinberg, J. S. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.04.016 · Cited by 185
Ziegler, P. D., Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Koehler, J. L., & Hilker, C. E. (2010) · Stroke · doi:10.1161/strokeaha.109.571455 · Cited by 173
Self-citationSwerdlow, C. D., Schšls, W., Dijkman, B., Jung, W., Sheth, N. V., Olson, W. H., Gunderson, B. D., & for the Worldwide Jewel AF Investigators (2000) · Circulation · doi:10.1161/01.cir.101.8.878 · Cited by 168
Ziegler, P., Glotzer, T. V., Daoud, E. G., Singer, D. E., Ezekowitz, M. D., HOYT, R. H., Koehler, J. L., Coles, J. A., & Wyse, D. G. (2012) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2012.06.034 · Cited by 164
Self-citationAccuracy of Atrial Tachyarrhythmia Detection in Implantable Devices with Arrhythmia Therapies
Pürerfellner, H., Gillis, A. M., Holbrook, R., & Hettrick, D. A. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00569.x · Cited by 162
Self-citationPokushalov, E. A., Romanov, A. B., CORBUCCI, G., Николаевич, А. С., Туров, А. Н., Shirokova, N., & Karaskov, A. M. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01923.x · Cited by 110
New devices for very long-term ECG monitoring
Lobodzinski, S. S., & Laks, M. M. (2012) · Cardiology Journal · doi:10.5603/cj.2012.0039 · Cited by 106
Accuracy of Mode Switch Algorithms for Detection of Atrial Tachyarrhythmias
PASSMAN, R. S., Weinberg, K. M., Freher, M., Schaechter, A., Goldberger, J. J., & Kadish, A. H. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.03537.x · Cited by 101
Quirino, G., Giammaria, M., CORBUCCI, G., Pistelli, P., Turri, E., Mazza, A., Perucca, A., Checchinato, C., Dalmasso, M., & Barold, S. S. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02181.x · Cited by 89
Martinek, M., Aichinger, J., Nesser, H., Ziegler, P., & Pürerfellner, H. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00883.x · Cited by 69
Self-citationSaksena, S. V., Hettrick, D. A., Koehler, J. L., Grammatico, A., & Padeletti, L. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.06.045 · Cited by 62
Dobreanu, D., Svendsen, J. H., Lewalter, T., Hernández‐Madrid, A., Lip, G. Y. H., & Blomström‐Lundqvist, C. (2013) · EP Europace · doi:10.1093/europace/eut227 · Cited by 45
Glotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Holbrook, R., Pruett, K., Smith, K., & Hilker, C. E. (2006) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-006-7622-y · Cited by 40
Self-citationSweeney, M. O., Sakaguchi, S., Simons, G. R., Machado, C., Connett, J. E., & Yang, F. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.02.027 · Cited by 18
Nagarakanti, R., Saksena, S. V., Hettrick, D. A., Koehler, J. L., Grammatico, A., & Padeletti, L. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9601-1 · Cited by 14
Ziegler, P., Koehler, J. L., & Verma, A. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03349.x · Cited by 9
Self-citation
Research works printed but not linked: 1
- Charitos, 2013, Atrial fibrillation density: A novel measure of atrial fibrillation temporal aggregation for the characterization of atrial fibrillation recurrence pattern, Appl Cardiopulm Pathophys, 17, 3
Cited by
Sorted by citations
Hindricks, G., Potpara, T., Dagres, N., Arbelo, E., Bax, J. J., Blomström‐Lundqvist, C., Boriani, G., Castella, M., Dan, G.-A., Dilaveris, P., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa612 · Cited by 10,550
Self-citation2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,438
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
“by long-term ECG monitoring.(163) Even less is known about the response to therapy in patients with long-standing persistent AF or long-standing paroxysmal AF.”
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezw313 · Cited by 1,403
Tzeis, S. E., Gerstenfeld, E. P., Kalman, J. M., Saad, E., Shamloo, A. S., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Bovéda, S., Calkins, H. G., et al. (2024) · EP Europace · doi:10.1093/europace/euae043 · Cited by 724
Self-citation
Metadata
- Authors
- Charitos, E. I., Pürerfellner, H., Glotzer, T. V., & Ziegler, P. D.
- Affiliations
- University of Lübeck (DE)
- Krankenhaus der Elisabethinen (AT)
- Hackensack University Medical Center (US)
- Medtronic (United States) (US)
- Corresponding author
- Charitos, Efstratios I.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2014-07
- Volume
- 63
- Issue
- 25
- Pages
- 2840-2848
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W191924134
- Cited by
- 188
- References
- 35
- Citations by year
- 2026: 10 · 2025: 16 · 2024: 23 · 2023: 11 · 2022: 14 · 2021: 20 · 2020: 15 · 2019: 9 · 2018: 17 · 2017: 18 · 2016: 13 · 2015: 15 · 2014: 7
- FWCI
- 12.12
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of the American College of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- atrial fibrillation, temporal persistence, clinical classification, paroxysmal atrial fibrillation, persistent atrial fibrillation, atrial fibrillation burden, cardiac implantable electronic devices, ejection fraction, coronary artery disease, patient selection
- MeSH terms
- Aged, Atrial Fibrillation, Equipment Design, Female, Heart Rate, Humans, Male, Middle Aged, Monitoring, Physiologic, Prospective Studies, Treatment Outcome, Cardiac Resynchronization Therapy Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review