Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 472

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Paroxysmal AF Catheter Ablation With a Contact Force Sensing Catheter

Open access
Natale, Andrea, Reddy, Vivek Y., Monir, George, Wilber, David J., Lindsay, Bruce D., McElderry, H. Thomas, Kantipudi, Charan, Mansour, Moussa C., Melby, Daniel P., Packer, Douglas L., Nakagawa, Hiroshi, Zhang, Baohui, Stagg, Robert B., Boo, Lee Ming, Marchlinski, Francis E.·2014·Journal of the American College of Cardiology

Abstract

BACKGROUND: Catheter ablation is important for treatment of paroxysmal atrial fibrillation (PAF). Limited animal and human studies suggest a correlation between electrode-tissue contact and radiofrequency lesion generation. OBJECTIVES: The study sought to assess the safety and effectiveness of an irrigated, contact force (CF)-sensing catheter in the treatment of drug refractory symptomatic PAF. METHODS: A prospective, multicenter, nonrandomized study was conducted. Enrollment criteria included: ≥3 symptomatic episodes of PAF within 6 months of enrollment and failure of ≥1 antiarrhythmic drug (Class I to IV). Ablation included pulmonary vein isolation with confirmed entrance block as procedural endpoint. RESULTS: A total of 172 patients were enrolled at 21 sites, where 161 patients had a study catheter inserted and 160 patients underwent radiofrequency application. Procedural-related serious adverse events occurring within 7 days of the procedure included tamponade (n = 4), pericarditis (n = 3), heart block (n = 1, prior to radiofrequency application), and vascular access complications (n = 4). By Kaplan-Meier analyses, 12-month freedom from atrial fibrillation/atrial flutter/atrial tachycardia recurrence was 72.5%. The average CF per procedure was 17.9 ± 9.4 g. When the CF employed was between investigator selected working ranges ≥80% of the time during therapy, outcomes were 4.25 times more likely to be successful (p = 0.0054; 95% confidence interval: 1.53 to 11.79). CONCLUSIONS: The SMART-AF trial demonstrated that this irrigated CF-sensing catheter is safe and effective for the treatment of drug refractory symptomatic PAF, with no unanticipated device-related adverse events. The increased percent of time within investigator-targeted CF ranges correlates with increased freedom from arrhythmia recurrence. Stable CF during radiofrequency application increases the likelihood of 12-month success. (THERMOCOOL® SMARTTOUCH® Catheter for Treatment of Symptomatic Paroxysmal Atrial Fibrillation; NCT01385202).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2014.04.072

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 472

Metadata

Authors
Natale, A., Reddy, V. Y., Monir, G., Wilber, D. J., Lindsay, B. D., McElderry, H. T., Kantipudi, C., Mansour, M. C., Melby, D. P., Packer, D. L., Nakagawa, H., Zhang, B., Stagg, R. B., Boo, L. M., & Marchlinski, F. E.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2014-08
Volume
64
Issue
7
Pages
647-656
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1602461739
Cited by
472
References
22
FWCI
36.43
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Paroxysmal AF Catheter Ablation With a Contact Force Sensing Catheter. https://app.cochat.ai/papers/10.1016/j.jacc.2014.04.072
The paper
Natale, A., Reddy, V. Y., Monir, G., Wilber, D. J., Lindsay, B. D., McElderry, H. T., Kantipudi, C., Mansour, M. C., Melby, D. P., Packer, D. L., Nakagawa, H., Zhang, B., Stagg, R. B., Boo, L. M., & Marchlinski, F. E. (2014). Paroxysmal AF Catheter Ablation With a Contact Force Sensing Catheter. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2014.04.072

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.