Durability of Treatment Effect Using a Drug-Coated Balloon for Femoropopliteal Lesions

Open access
Laird, John R., Schneider, Peter A., Tepe, Gunnar, Brodmann, Marianne, Zeller, Thomas, Metzger, Christopher, Krishnan, Prakash, Scheinert, Dierk, Micari, Antonio, Cohen, David J., Wang, Hong, Hasenbank, Melissa S., Jaff, Michael R.·2015·Journal of the American College of Cardiology

Abstract

BACKGROUND: Evidence from large, randomized, controlled peripheral artery disease trials reporting long-term outcomes using drug-coated balloons (DCBs) is limited. Previously, the DCB showed favorable 1-year outcomes compared with conventional percutaneous transluminal angioplasty (PTA), yet durability of the treatment effect with DCBs remains unknown. OBJECTIVES: This study sought to investigate the longer-term outcomes of a paclitaxel-eluting DCB compared to PTA for femoropopliteal lesions. METHODS: We enrolled 331 patients with symptomatic (Rutherford 2 to 4) femoropopliteal lesions up to 18 cm in length. Patients were randomly assigned in a 2:1 ratio to treatment with DCB or PTA. The 24-month assessments included primary patency, freedom from clinically driven target lesion revascularization (CD-TLR), major adverse events, and quality of life and functional outcomes as assessed by the EuroQOL-5D quality-of-life questionnaire, walking impairment questionnaire, and 6-min walk test. RESULTS: At 24 months, patients treated with DCB showed significantly higher primary patency when compared with PTA (78.9% vs. 50.1%; p < 0.001). The rates of CD-TLR were 9.1% and 28.3% (p < 0.001) for the DCB and PTA groups, respectively. The overall mortality rate in the DCB group was 8.1% versus 0.9% in the PTA group (p = 0.008). There were no device- or procedure-related deaths and no major amputations in either group through 24-month follow-up. The rate of vessel thrombosis was low (1.5% DCB vs. 3.8% PTA; p = 0.243), with no new events reported between 1 and 2 years. Both groups showed similar functional improvement at 2 years, although DCB patients achieved this level of function with 58% fewer reinterventions. CONCLUSIONS: The 24-month outcomes from the trial demonstrate a durable and superior treatment effect of DCB versus PTA with significantly higher primary patency, lower CD-TLR, and similar functional status improvement with fewer repeat interventions. (Randomized Trial of IN.PACT Admiral Drug Eluting Balloon vs Standard PTA for the Treatment of SFA and Proximal Popliteal Arterial Disease [INPACT SFA I]; NCT01175850; and IN.PACT Admiral Drug-Coated Balloon vs. Standard Balloon Angioplasty for the Treatment of Superficial Femoral Artery [SFA] and Proximal Popliteal Artery [PPA] [INPACT SFA II]; NCT01566461).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2015.09.063

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 382

Metadata

Authors
Laird, J. R., Schneider, P. A., Tepe, G., Brodmann, M., Zeller, T., Metzger, C., Krishnan, P., Scheinert, D., Micari, A., Cohen, D. J., Wang, H., Hasenbank, M. S., & Jaff, M. R.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2015-12
Volume
66
Issue
21
Pages
2329-2338
ISSN
0735-1097 (ISSN-L)
OpenAlex
W1944762875
Cited by
382
References
24
FWCI
42.72
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Durability of Treatment Effect Using a Drug-Coated Balloon for Femoropopliteal Lesions. https://app.cochat.ai/papers/10.1016/j.jacc.2015.09.063
The paper
Laird, J. R., Schneider, P. A., Tepe, G., Brodmann, M., Zeller, T., Metzger, C., Krishnan, P., Scheinert, D., Micari, A., Cohen, D. J., Wang, H., Hasenbank, M. S., & Jaff, M. R. (2015). Durability of Treatment Effect Using a Drug-Coated Balloon for Femoropopliteal Lesions. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2015.09.063

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.