The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis
Open accessAbstract
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is being increasingly performed in patients with bicuspid aortic valve stenosis (AS). OBJECTIVES: This study sought to compare the procedural and clinical outcomes in patients with bicuspid versus tricuspid AS from the Bicuspid AS TAVR multicenter registry. METHODS: Outcomes of 561 patients with bicuspid AS and 4,546 patients with tricuspid AS were compared after propensity score matching, assembling 546 pairs of patients with similar baseline characteristics. Procedural and clinical outcomes were recorded according to Valve Academic Research Consortium-2 criteria. RESULTS: Compared with patients with tricuspid AS, patients with bicuspid AS had more frequent conversion to surgery (2.0% vs. 0.2%; p = 0.006) and a significantly lower device success rate (85.3% vs. 91.4%; p = 0.002). Early-generation devices were implanted in 320 patients with bicuspid and 321 patients with tricuspid AS, whereas new-generation devices were implanted in 226 and 225 patients with bicuspid and tricuspid AS, respectively. Within the group receiving early-generation devices, bicuspid AS had more frequent aortic root injury (4.5% vs. 0.0%; p = 0.015) when receiving the balloon-expanding device, and moderate-to-severe paravalvular leak (19.4% vs. 10.5%; p = 0.02) when receiving the self-expanding device. Among patients with new-generation devices, however, procedural results were comparable across different prostheses. The cumulative all-cause mortality rates at 2 years were comparable between bicuspid and tricuspid AS (17.2% vs. 19.4%; p = 0.28). CONCLUSIONS: Compared with tricuspid AS, TAVR in bicuspid AS was associated with a similar prognosis, but lower device success rate. Procedural differences were observed in patients treated with the early-generation devices, whereas no differences were observed with the new-generation devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationTranscatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients
Leon, M. B., Smith, C. R., Mack, M. J., Makkar, R. R., Svensson, L. G., Kodali, S. K., Thourani, V. H., Tuzcu, E. M., Miller, D. C., Herrmann, H. C., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1514616 · Cited by 5,053
Self-citationKappetein, A. P., Head, S. J., Généreux, P., Piazza, N., Mieghem, N. M. V., Blackstone, E., Brott, T., Cohen, D., Cutlip, D. E., van Es, G., et al. (2012) · doi:10.48350/15011 · Cited by 3,368
Self-citationTranscatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis
Adams, D. H., Popma, J. J., Reardon, M. J., Yakubov, S. J., Coselli, J. S., Deeb, G. M., Gleason, T. G., Buchbinder, M., Hermiller, J., Kleiman, N. S., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1400590 · Cited by 2,902
Updated Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation
Kappetein, A. P., Head, S. J., Généreux, P., Piazza, N., van Mieghem, N. M., Blackstone, E. H., Brott, T. G., Cohen, D. J., Cutlip, D. E., van Es, G.-A., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.001 · Cited by 1,668
Self-citationRegistry of Transcatheter Aortic-Valve Implantation in High-Risk Patients
Gilard, M., Eltchaninoff, H., Iung, B., Donzeau-Gouge, P., Chevreul, K., Fajadet, J., Leprince, P., Leguerrier, A., Lievre, M., Prat, A., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114705 · Cited by 1,228
A classification system for the bicuspid aortic valve from 304 surgical specimens
Sievers, H.-H., & Schmidtke, C. (2007) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.01.039 · Cited by 1,222
Two-dimensional echocardiographic aortic root dimensions in normal children and adults
Roman, M. J., Devereux, R. B., Kramer-Fox, R., & O'Loughlin, J. (1989) · The American Journal of Cardiology · doi:10.1016/0002-9149(89)90430-x · Cited by 1,102
Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Self-citation
Cited by
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehab395 · Cited by 5,685
Self-citation2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Self-citation2021 ESC/EACTS Guidelines for the management of valvular heart disease
Beyersdorf, F., Vahanian, A., Milojevic, M., Praz, F., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2021) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezab389 · Cited by 622
Self-citationBlanke, P., Weir-McCall, J. R., Achenbach, S., Delgado, V., Hausleiter, J., Jilaihawi, H., Marwan, M., Norgaard, B. L., Piazza, N., Schoenhagen, P., et al. (2019) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2018.11.008 · Cited by 543
Self-citationVahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2022.05.006 · Cited by 527
Self-citation
Metadata
- Authors
- Yoon, S.-H., Bleiziffer, S., De Backer, O., Delgado, V., Arai, T., Ziegelmueller, J., Barbanti, M., Sharma, R., Perlman, G. Y., Khalique, O. K., Holy, E. W., Saraf, S., Deuschl, F., Fujita, B., Ruile, P., Neumann, F.-J., Pache, G., Takahashi, M., Kaneko, H., Schmidt, T., Ohno, Y., Schofer, N., Kong, W. K. F., Tay, E., Sugiyama, D., Kawamori, H., Maeno, Y., Abramowitz, Y., Chakravarty, T., Nakamura, M., Kuwata, S., Yong, G., Kao, H.-L., Lee, M., Kim, H.-S., Modine, T., Wong, S. C., Bedgoni, F., Testa, L., Teiger, E., Butter, C., Ensminger, S. M., Schaefer, U., Dvir, D., Blanke, P., Leipsic, J., Nietlispach, F., Abdel-Wahab, M., Chevalier, B., Tamburino, C., Hildick-Smith, D., Whisenant, B. K., Park, S.-J., Colombo, A., Latib, A., Kodali, S. K., Bax, J. J., Søndergaard, L., Webb, J. G., Lefèvre, T., Leon, M. B., & Makkar, R.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2017-05
- Volume
- 69
- Issue
- 21
- Pages
- 2579-2589
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2595545849
- Cited by
- 489
- References
- 34
- FWCI
- 38.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis. https://app.cochat.ai/papers/10.1016/j.jacc.2017.03.017
- The paper
- Yoon, S.-H., Bleiziffer, S., De Backer, O., Delgado, V., Arai, T., Ziegelmueller, J., Barbanti, M., Sharma, R., Perlman, G. Y., Khalique, O. K., Holy, E. W., Saraf, S., Deuschl, F., Fujita, B., Ruile, P., Neumann, F.-J., Pache, G., Takahashi, M., Kaneko, H., . . . Makkar, R. (2017). Outcomes in Transcatheter Aortic Valve Replacement for Bicuspid Versus Tricuspid Aortic Valve Stenosis. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2017.03.017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.