CoChat

Sham-Controlled Randomized Trials of Catheter-Based Renal Denervation in Patients With Hypertension

Open access
Sardar, Partha, Bhatt, Deepak L., Kirtane, Ajay J., Kennedy, Kevin F., Chatterjee, Saurav, Giri, Jay, Soukas, Peter A., White, William B., Parikh, Sahil A., Aronow, Herbert D. · 2019 · Journal of the American College of Cardiology
Cited by 86

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND There are conflicting data regarding the relative effectiveness of renal sympathetic denervation (RSD) in patients with hypertension. OBJECTIVES The purpose of this study was to evaluate the blood pressure (BP) response after RSD in sham-controlled randomized trials. METHODS Databases were searched through June 30, 2018. Randomized trials (RCTs) with ≥50 patients comparing catheter-based RSD with a sham control were included. The authors calculated summary treatment estimates as weighted mean differences (WMD) with 95% confidence intervals (CIs) using random-effects meta-analysis. RESULTS The analysis included 977 patients from 6 trials. The reduction in 24-h ambulatory systolic blood pressure (ASBP) was significantly greater for patients treated with RSD than sham procedure (WMD -3.65 mm Hg, 95% CI: -5.33 to -1.98; p < 0.001). Compared with sham, RSD was also associated with a significant decrease in daytime ASBP (WMD -4.07 mm Hg, 95% CI: -6.46 to -1.68; p < 0.001), office systolic BP (WMD -5.53 mm Hg, 95% CI: -8.18 to -2.87; p < 0.001), 24-h ambulatory diastolic BP (WMD -1.71 mm Hg, 95% CI: -3.06 to -0.35; p = 0.01), daytime ambulatory diastolic BP (WMD -1.57 mm Hg, 95% CI: -2.73 to -0.42; p = 0.008), and office diastolic BP (WMD -3.37 mm Hg, 95% CI: -4.86 to -1.88; p < 0.001). Compared with first-generation trials, a significantly greater reduction in daytime ASBP was observed with RSD in second-generation trials (6.12 mm Hg vs. 2.14 mm Hg; p interaction = 0.04); however, this interaction was not significant for 24-h ASBP (4.85 mm Hg vs. 2.23 mm Hg; p interaction = 0.13). CONCLUSIONS RSD significantly reduced blood pressure compared with sham control. Results of this meta-analysis should inform the design of larger, pivotal trials to evaluate the long-term efficacy and safety of RSD in patients with hypertension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2018.12.082

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 86

Metadata

Authors
Sardar, P., Bhatt, D. L., Kirtane, A. J., Kennedy, K. F., Chatterjee, S., Giri, J., Soukas, P. A., White, W. B., Parikh, S. A., & Aronow, H. D.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2019-04
Volume
73
Issue
13
Pages
1633-1642
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2928311395
Cited by
86
References
5
FWCI
11.08
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sham-Controlled Randomized Trials of Catheter-Based Renal Denervation in Patients With Hypertension. https://app.cochat.ai/papers/10.1016/j.jacc.2018.12.082
The paper
Sardar, P., Bhatt, D. L., Kirtane, A. J., Kennedy, K. F., Chatterjee, S., Giri, J., Soukas, P. A., White, W. B., Parikh, S. A., & Aronow, H. D. (2019). Sham-Controlled Randomized Trials of Catheter-Based Renal Denervation in Patients With Hypertension. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2018.12.082

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.