3-Year Outcomes After Valve-in-Valve Transcatheter Aortic Valve Replacement for Degenerated Bioprostheses
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND Transcatheter aortic valve replacement (TAVR) for degenerated surgical bioprosthetic aortic valves is associated with favorable early outcomes. However, little is known about the durability and longer-term outcomes associated with this therapy. OBJECTIVES The aim of this study was to examine late outcomes after valve-in-valve TAVR. METHODS Patients with symptomatic degeneration of surgical aortic bioprostheses at high risk (≥50% major morbidity or mortality) for reoperative surgery were prospectively enrolled in the multicenter PARTNER (Placement of Aortic Transcatheter Valves) 2 valve-in-valve and continued access registries. Three-year clinical and echocardiographic follow-up was obtained. RESULTS Valve-in-valve procedures were performed in 365 patients. The mean age was 78.9 ± 10.2 years, and the mean Society of Thoracic Surgeons score was 9.1 ± 4.7%. At 3 years, the overall Kaplan-Meier estimate of all-cause mortality was 32.7%. Aortic valve re-replacement was required in 1.9%. Mean transaortic gradient was 35.0 mm Hg at baseline, decreasing to 17.8 mm Hg at 30-day follow-up and 16.6 mm Hg at 3-year follow-up. Baseline effective orifice area was 0.93 cm2, increasing to 1.13 and 1.15 cm2 at 30 days and 3 years, respectively. Moderate to severe aortic regurgitation was reduced from 45.1% at pre-TAVR baseline to 2.5% at 3 years. Importantly, moderate or severe mitral and tricuspid regurgitation also decreased (33.7% vs. 8.6% [p < 0.0001] and 29.7% vs. 18.8% [p = 0.002], respectively). Baseline left ventricular ejection fraction was 50.7%, increasing to 54.7% at 3 years (p < 0.0001), while left ventricular mass index was 136.4 g/m2, decreasing to 109.1 g/m2 at 3 years (p < 0.0001). New York Heart Association functional class improved, with 90.4% in class III or IV at baseline and 14.1% at 3 years (p < 0.0001), and Kansas City Cardiomyopathy Questionnaire overall score increased (43.1 to 73.1; p < 0.0001). CONCLUSIONS At 3-year follow-up, TAVR for bioprosthetic aortic valve failure was associated with favorable survival, sustained improved hemodynamic status, and excellent functional and quality-of-life outcomes. (The PARTNER II Trial: Placement of Aortic Transcatheter Valves II - PARTNER II - Nested Registry 3/Valve-in-Valve [PII NR3/ViV]; NCT03225001).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationTranscatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
Dvir, D., Webb, J. G., Bleiziffer, S., Pasic, M., Waksman, R., Kodali, S., Barbanti, M., Latib, A., Schaefer, U., Rodés-Cabau, J., et al. (2014) · JAMA · doi:10.1001/jama.2014.7246 · Cited by 923
Self-citationDvir, D., Bourguignon, T., Otto, C. M., Hahn, R. T., Rosenhek, R., Webb, J. G., Treede, H., Sarano, M. E., Feldman, T., Wijeysundera, H. C., et al. (2018) · Circulation · doi:10.1161/circulationaha.117.030729 · Cited by 479
Self-citationTranscatheter Aortic Valve Implantation Within Degenerated Aortic Surgical Bioprostheses
Webb, J. G., Mack, M. J., White, J. M., Dvir, D., Blanke, P., Herrmann, H. C., Leipsic, J., Kodali, S. K., Makkar, R., Miller, D. C., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.02.057 · Cited by 327
Self-citationTranscatheter Aortic Valve Replacement of Failed Surgically Implanted Bioprostheses
Tuzcu, E. M., Kapadia, S. R., Vemulapalli, S., Carroll, J. D., Holmes, D. R., Mack, M. J., Thourani, V. H., Grover, F. L., Brennan, J. M., Suri, R. M., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.04.074 · Cited by 176
Self-citationTranscatheter Aortic and Mitral Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves
Ye, J., Cheung, A. W., Yamashita, M. H., Wood, D. A., Peng, D., Gao, M., Thompson, C., Munt, B. I., Moss, R., Blanke, P., et al. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.08.012 · Cited by 149
Self-citationPîbarot, P., Simonato, M., Barbanti, M., Linke, A. H.-P., Kornowski, R., Rudolph, T. K., Spence, M., Moat, N. E., Aldea, G. S., Mennuni, M. G., et al. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.08.039 · Cited by 136
Self-citationDeeb, G. M., Chetcuti, S. J., Reardon, M. J., Patel, H. J., Grossman, P. M., SCHREIBER, T. L., Forrest, J. K., BAJWA, T. K., O’Hair, D. P., Petrossian, G., et al. (2017) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2017.03.018 · Cited by 123
Longitudinal Hemodynamics of Transcatheter and Surgical Aortic Valves in the PARTNER Trial
Douglas, P. S., Leon, M. B., Mack, M. J., Svensson, L. G., Webb, J. G., Hahn, R. T., Pîbarot, P., Weissman, N. J., Miller, D. C., Kapadia, S. R., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2017.3306 · Cited by 89
Self-citationIncidence, predictors and clinical outcomes of residual stenosis after aortic valve-in-valve
Bleiziffer, S., Erlebach, M., Simonato, M., Pîbarot, P., Webb, J. G., Capek, L., Windecker, S., George, I., Sinning, J., Horlick, E. M., et al. (2018) · Heart · doi:10.1136/heartjnl-2017-312422 · Cited by 81
Self-citationLong-Term Outcomes After Transcatheter Aortic Valve-in-Valve Replacement
Guimaraes, L. D. F. C., Ureña, M., Wijeysundera, H. C., Muñoz-García, A. J., Serra, V., Benitez, L. M., Auffret, V., Cheema, A. N., Amat-Santos, I. J., Fischer, Q., et al. (2018) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.118.007038 · Cited by 51
Will Transcatheter Replacement Become the New Default Therapy When Bioprosthetic Valves Fail?
Webb, J. G., Murdoch, D. J., & Dvir, D. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.04.073 · Cited by 6
Self-citation
Cited by
Zoghbi, W. A., Jone, P.-N., Chamsi-Pasha, M. A., Chen, T., Collins, K. A., Desai, M. Y., Grayburn, P., Groves, D. W., Hahn, R. T., Little, S. H., et al. (2024) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2023.10.004 · Cited by 197
Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic valves
Bleiziffer, S., Simonato, M., Webb, J. G., Rodés-Cabau, J., Pibarot, P., Kornowski, R., Windecker, S., Erlebach, M., Duncan, A., Seiffert, M., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa544 · Cited by 169
“Survival after aortic ViV was recently reported in a smaller cohort of high-risk patients from the PARTNER trial.(23) Patients had a mean age of 78.”
Self-citation
Metadata
- Authors
- Webb, J. G., Murdoch, D. J., Alu, M. C., Cheung, A., Crowley, A., Dvir, D., Herrmann, H. C., Kodali, S. K., Leipsic, J., Miller, D. C., Pibarot, P., Suri, R. M., Wood, D., Leon, M. B., & Mack, M. J.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 73
- Issue
- 21
- Pages
- 2647-2655
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2947163387
- Cited by
- 166
- References
- 12
- FWCI
- 17.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.