CoChat

Risk Factors for Infections Involving Cardiac Implanted Electronic Devices

Open access
Birnie, David H., Wang, Jia, Alings, Marco, Philippon, François, Parkash, Ratika, Manlucu, Jaimie, Angaran, Paul, Rinne, Claus, Coutu, Benoit, Low, R. Aaron, Essebag, Vidal, Morillo, Carlos, Redfearn, Damian, Toal, Satish, Becker, Giuliano, Degrâce, Michel, Thibault, Bernard, Crystal, Eugene, Tung, Stanley, LeMaitre, John, Sultan, Omar, Bennett, Matthew, Bashir, Jamil, Ayala-Paredes, Felix, Gervais, Philippe, Rioux, Leon, Hemels, Martin E.W., Bouwels, Leon H.R., Exner, Derek V., Dorian, Paul, Connolly, Stuart J., Longtin, Yves, Krahn, Andrew D. · 2019 · Journal of the American College of Cardiology
Cited by 173

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND Cardiac implantable electronic device infection is a major complication that usually requires device removal. PADIT (Prevention of Arrhythmia Device Infection Trial) was a large cluster crossover trial of conventional versus incremental antibiotics. OBJECTIVES This study sought to investigate independent predictors of device infection in PADIT and develop a novel infection risk score. METHODS In brief, over 4 6-month periods, 28 centers used either conventional or incremental prophylactic antibiotic treatment in all patients. The primary outcome was hospitalization for device infection within 1 year (blinded endpoint adjudication). Multivariable logistic prediction modeling was used to identify the independent predictors and develop a risk score for device infection. The prediction models were internally validated with bootstrap methods. RESULTS Device procedures were performed in 19,603 patients, and hospitalization for infection occurred in 177 (0.90%) within 1 year of follow-up. The final prediction model identified 5 independent predictors of device infection (prior procedures [P], age [A], depressed renal function [D], immunocompromised [I], and procedure type [T]) with an optimism-corrected C-statistic of 0.704 (95% confidence interval: 0.660 to 0.744). A PADIT risk score ranging from 0 to 15 points classified patients into low (0 to 4), intermediate (5 to 6) and high (≥7) risk groups with rates of hospitalization for infection of 0.51%, 1.42%, and 3.41%, respectively. CONCLUSIONS This study identified 5 independent predictors of device infection and developed a novel infection risk score in the largest cardiac implantable electronic device trial to date, warranting validation in an independent cohort. The 5 independent predictors in the PADIT score are readily adopted into clinical practice. (Prevention of Arrhythmia Device Infection Trial [PADIT Pilot]; NCT01002911).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2019.09.060

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 173

Metadata

Authors
Birnie, D. H., Wang, J., Alings, M., Philippon, F., Parkash, R., Manlucu, J., Angaran, P., Rinne, C., Coutu, B., Low, R. A., Essebag, V., Morillo, C., Redfearn, D., Toal, S., Becker, G., Degrâce, M., Thibault, B., Crystal, E., Tung, S., LeMaitre, J., Sultan, O., Bennett, M., Bashir, J., Ayala-Paredes, F., Gervais, P., Rioux, L., Hemels, M. E. W., Bouwels, L. H. R., Exner, D. V., Dorian, P., Connolly, S. J., Longtin, Y., & Krahn, A. D.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2019-12
Volume
74
Issue
23
Pages
2845-2854
ISSN
0735-1097 (ISSN-L)
OpenAlex
W2994006966
Cited by
173
References
2
FWCI
12.09
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.