Safety of Transesophageal Echocardiography to Guide Structural Cardiac Interventions
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
BACKGROUND Despite the widespread use of transesophageal echocardiography (TEE) to guide structural cardiac interventions, studies evaluating safety in this context are lacking. OBJECTIVES This study sought to determine the incidence, types of complications, and factors associated with esophageal or gastric lesions following TEE manipulation during structural cardiac interventions. METHODS This was a prospective study including 50 patients undergoing structural cardiac interventions in which TEE played a central role in guiding the procedure (mitral and tricuspid valve repair, left atrial appendage closure, and paravalvular leak closure). An esophagogastroduodenoscopy (EGD) was performed before and immediately after the procedure to look for new injuries that might have arisen during the course of the intervention. Patients were divided in 2 cohorts according to the type of injury: complex lesions (intramural hematoma, mucosal laceration) and minor lesions (petechiae, ecchymosis). The factors associated with an increased risk of complications were assessed. RESULTS Post-procedural EGD showed a new injury in 86% (n = 43 of 50) of patients, with complex lesions accounting for 40% (n = 20 of 50) of cases. Patients with complex lesions presented more frequently with an abnormal baseline EGD (70% vs. 37%; p = 0.04) and had a higher incidence of post-procedural dysphagia or odynophagia (40% vs. 10%; p = 0.02). Independent factors associated with an increased risk of complex lesions were a longer procedural time under TEE manipulation (for each 10-min increment in imaging time, odds ratio: 1.27; 95% confidence interval: 1.01 to 1.59) and poor or suboptimal image quality (odds ratio: 4.93; 95% confidence interval: 1.10 to 22.02). CONCLUSIONS Most patients undergoing structural cardiac interventions showed some form of injury associated with TEE, with longer procedural time and poor or suboptimal image quality determining an increased risk. Imaging experts performing this technique should be aware of the nature of potential complications, to take the necessary precautions to prevent their occurrence and facilitate early diagnosis and treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2017 ESC/EACTS Guidelines for the management of valvular heart disease
Baumgartner, H., Falk, V., Bax, J. J., De Bonis, M., Hamm, C., Holm, P. J., Iung, B., Lancellotti, P., Lansac, E., Rodriguez Muñoz, D., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehx391 · Cited by 6,243
Bias reduction of maximum likelihood estimates
FIRTH, D. (1993) · Biometrika · doi:10.1093/biomet/80.1.27 · Cited by 5,035 · cited 1×
“Owing to a low event per variable ratio, the logistic regression model was penalized using the Firth bias correction (13).”
MethodHahn, R. T., Abraham, T., Adams, M. S., Bruce, C. J., Glas, K. E., Lang, R. M., Reeves, S. T., Shanewise, J. S., Siu, S. C., Stewart, W., et al. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.07.009 · Cited by 1,351
Safety of Transesophageal Echocardiography
Hilberath, J. N., Oakes, D. A., Shernan, S. K., Bulwer, B. E., D’Ambra, M. N., & Eltzschig, H. K. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.08.013 · Cited by 612 · cited 4×
“Direct mechanical trauma might be related to blind insertion and advancement of an improperly placed probe or with forced manipulation of a well-placed one, which is sometimes required to achieve certain views needed for procedural guidance (5,8).”
BackgroundResultInfluentialDoherty, J. U., Gluckman, T. J., Hucker, W. J., Januzzi, J. L., Ortel, T. L., Saxonhouse, S. J., & Spinler, S. A. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.11.024 · Cited by 441
Recommendations for transoesophageal echocardiography: update 2010
Flachskampf, F. A., Badano, L., Daniel, W. G., Feneck, R. O., Fox, K. F., Fraser, A. G., Pasquet, A., Pepi, M., Perez de Isla, L., Zamorano, J. L., et al. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jeq057 · Cited by 354
&NA; (2002) · Survey of Anesthesiology · doi:10.1097/00132586-200210000-00008 · Cited by 328
Di Biase, L., Saenz, L. C., Burkhardt, D. J., Vacca, M., Elayi, C. S., Barrett, C. D., Horton, R., Bai, R., Siu, A., Fahmy, T. S., et al. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.815266 · Cited by 229 · cited 1×
“(17) showed that patients undergoing ablation for atrial fibrillation (AF) under GA had a higher incidence of esophageal injury detected by capsule endoscopy as compared with conscious sedation.”
BackgroundRecommendations for transoesophageal echocardiography: EACVI update 2014
Flachskampf, F. A., Wouters, P. F., Edvardsen, T., Evangelista, A., Habib, G., Hoffman, P., Hoffmann, R., Lancellotti, P., Pepi, M., & for the European Association of Cardiovascular Imaging Document reviewers: Erwan Donal and Fausto Rigo (2014) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu015 · Cited by 189 · cited 1×
“T ransesophageal echocardiography (TEE) has become an invaluable monitoring adjunct for operative and percutaneous interventions by providing real-time information to help guide and assess procedural results (1).”
BackgroundTransesophageal echocardiography complications associated with interventional cardiology procedures
Freitas‐Ferraz, A. B., Rodés‐Cabau, J., Junquera, L., Beaudoin, J., O’Connor, K., Turgeon, P. Y., Paradis, J., Ferreira‐Neto, A. N., Asmarats, L., Champagne, J., et al. (2019) · American Heart Journal · doi:10.1016/j.ahj.2019.11.018 · Cited by 81 · cited 1×
“Moreover, in a recently published retrospective study, we observed that the duration of active TEE imaging increased the risk of injury and was associated with higher rates of major TEE-related morbidity in patients undergoing procedures requiring active probe manipulation compared with transaortic valve replacement,…”
BackgroundSelf-citationTranscatheter heart valve interventions: where are we? Where are we going?
Prendergast, B., Baumgartner, H., Delgado, V., Gérard, O., Haude, M., Himmelmänn, A., Iung, B., Leafstedt, M., Lennartz, J., Maisano, F., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy668 · Cited by 79 · cited 1×
“rise to advances in percutaneous transcatheter technologies and a growing number of increasingly complex interventions being performed (14,15).”
BackgroundGastroesophageal Perforation after Intraoperative Transesophageal Echocardiography
Kharasch, E. D., & Sivarajan, M. (1996) · Anesthesiology · doi:10.1097/00000542-199608000-00027 · Cited by 72 · cited 1×
“Finally, thermal injury caused by the heat or ultrasound energy produced by the TEE probe, especially in patients with severe atherosclerosis, might play a contributory role (20).”
BackgroundO’Shea, J. P., Southern, J. F., DʼAmbra, M. N., Magro, C., Guerrero, J. L., Marshall, J. E., Vlahakes, G. V., Levine, R. A., & Weyman, A. E. (1991) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80158-5 · Cited by 65 · cited 1×
“A high surface contact pressure exerted at the mucosal-probe interface has also been postulated as a potential mechanism that could lead to injury and necrosis, although this theory is not clearly supported by animal and human studies (5,18,19).”
ResultHahn, R. T. (2016) · Circulation Research · doi:10.1161/circresaha.116.307972 · Cited by 59 · cited 1×
“To guide these procedures, TEE plays an instrumental role by monitoring the procedural steps in order to improve results and minimize complications (16).”
Greene, M. A., Alexander, J. A., Knauf, D. G., Talbert, J. L., Langham, M. R., Kays, D. W., & Ledbetter, D. (1999) · CHEST Journal · doi:10.1378/chest.116.5.1247 · Cited by 57 · cited 2×
“Because the prevalence of TEE-related injuries found in previous studies with systematic endoscopic evaluation was relatively high (30% to 64%) (11,12), it was considered that this sample size would allow for an appropriate description of the type of lesions associated with TEE manipulation.”
BackgroundKumar, S., Brown, G. J., Sutherland, F., MORGAN, J., Andrews, D. T., Ling, L., McLellan, A. J. A., Lee, G., Robinson, T., Heck, P. M., et al. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12575 · Cited by 51 · cited 5×
“In line with surgical series, we have also found that a prolonged procedure was associated with an increased risk of TEE complications, a finding that has also been replicated in the setting of patients undergoing AF ablation with TEE (11).”
BackgroundMethodResultInfluentialFaustino, M., Abecasis, J., Freitas, A., de Gouveia, R. H., & Gil, V. M. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet185 · Cited by 14
Metadata
- Authors
- Freitas-Ferraz, A. B., Bernier, M., Vaillancourt, R., Ugalde, P. A., Nicodème, F., Paradis, J.-M., Champagne, J., O’Hara, G., Junquera, L., del Val, D., Muntané-Carol, G., O’Connor, K., Beaudoin, J., & Rodés-Cabau, J.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 75
- Issue
- 25
- Pages
- 3164-3173
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W3035812436
- Cited by
- 184
- References
- 17
- FWCI
- 13.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.