The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Esophageal Capsule Endoscopy After Radiofrequency Catheter Ablation for Atrial Fibrillation: Documented Higher Risk of Luminal Esophageal Damage With General Anesthesia as Compared With Conscious Sedation
Abstract
Background— Left atrioesophageal fistula is a rare but devastating complication that may occur after catheter ablation of atrial fibrillation. We used capsule endoscopy to assess esophageal injury after catheter ablation for atrial fibrillation in a population randomized to undergo general anesthesia or conscious sedation. Methods and Results— Fifty patients undergoing atrial fibrillation ablation for paroxysmal symptomatic atrial fibrillation refractory to antiarrhythmic drugs were enrolled and randomized, including those undergoing the procedure under general anesthesia (25 patients, group 1) and those receiving conscious sedation with fentanyl or midazolam (25 patients, group 2). All patients underwent esophageal temperature monitoring during the procedure. The day after ablation, all patients had capsule endoscopy to assess the presence of endoluminal tissue damage of the esophagus. We observed esophageal tissue damage in 12 (48%) patients of group 1 and 1 esophageal tissue damage in a single patient (4%) of group 2 ( P <0.001). The maximal esophageal temperature was significantly higher in patients undergoing general anesthesia (group 1) versus patients undergoing conscious sedation (group 2) (40.6�1�C versus 39.6�0.8�C; P < 0.003). The time to peak temperature was 9�7 seconds in group 1 and 21�9 seconds in group 2, and this difference was statistically significant ( P <0.001). No complication occurred during or after the administration of the pill cam or during the procedures. All esophageal lesions normalized at the 2-month repeat endoscopic examination. Conclusion— The use of general anesthesia increases the risk of esophageal damage detected by capsule endoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citation
Metadata
- Authors
- Di Biase, L., Saenz, L. C., Burkhardt, D. J., Vacca, M., Elayi, C. S., Barrett, C. D., Horton, R., Bai, R., Siu, A., Fahmy, T. S., Patel, D., Armaganijan, L., Wu, C. T., Kai, S., Ching, C. K., Phillips, K., Schweikert, R. A., Cummings, J. E., Arruda, M., Saliba, W. I., Dodig, M., & Natale, A.
- Venue
- Circulation: Arrhythmia and Electrophysiology
- Published
- 2009-04
- Volume
- 2
- Issue
- 2
- Pages
- 108-112
- ISSN
- 1941-3084 (ISSN-L)
- 1941-3149
- OpenAlex
- W2100588913
- Cited by
- 229
- References
- 1
- FWCI
- 9.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Esophageal Capsule Endoscopy After Radiofrequency Catheter Ablation for Atrial Fibrillation: Documented Higher Risk of Luminal Esophageal Damage With General Anesthesia as Compared With Conscious Sedation. https://app.cochat.ai/papers/10.1161/circep.108.815266
- The paper
- Di Biase, L., Saenz, L. C., Burkhardt, D. J., Vacca, M., Elayi, C. S., Barrett, C. D., Horton, R., Bai, R., Siu, A., Fahmy, T. S., Patel, D., Armaganijan, L., Wu, C. T., Kai, S., Ching, C. K., Phillips, K., Schweikert, R. A., Cummings, J. E., Arruda, M., . . . Natale, A. (2009). Esophageal Capsule Endoscopy After Radiofrequency Catheter Ablation for Atrial Fibrillation: Documented Higher Risk of Luminal Esophageal Damage With General Anesthesia as Compared With Conscious Sedation. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.108.815266
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.