Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 217

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Structural Deterioration of Transcatheter Versus Surgical Aortic Valve Bioprostheses in the PARTNER-2 Trial

Open access
Pibarot, Philippe, Ternacle, Julien, Jaber, Wael A., Salaun, Erwan, Dahou, Abdellaziz, Asch, Federico M., Weissman, Neil J., Rodriguez, Leonardo, Xu, Ke, Annabi, Mohamed-Salah, Guzzetti, Ezequiel, Beaudoin, Jonathan, Bernier, Mathieu, Leipsic, Jonathon, Blanke, Philipp, Clavel, Marie-Annick, Rogers, Erin, Alu, Maria C., Douglas, Pamela S., Makkar, Raj, Miller, D. Craig, Kapadia, Samir R., Mack, Michael J., Webb, John G., Kodali, Susheel K., Smith, Craig R., Herrmann, Howard C., Thourani, Vinod H., Leon, Martin B., Hahn, Rebecca T. · 2020 · Journal of the American College of Cardiology

Abstract

BACKGROUND It is unknown whether transcatheter valves will have similar durability as surgical bioprosthetic valves. Definitions of structural valve deterioration (SVD), based on valve related reintervention or death, underestimate the incidence of SVD. OBJECTIVES This study sought to determine and compare the 5-year incidence of SVD, using new standardized definitions based on echocardiographic follow-up of valve function, in intermediate-risk patients with severe aortic stenosis given transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) in the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and registry. METHODS In the PARTNER 2A trial, patients were randomly assigned to receive either TAVR with the SAPIEN XT or SAVR, whereas in the SAPIEN 3 registry, patients were assigned to TAVR with the SAPIEN 3. The primary endpoint was the incidence of SVD, that is, the composite of SVD-related hemodynamic valve deterioration during echocardiographic follow-up and/or SVD-related bioprosthetic valve failure (BVF) at 5 years. RESULTS Compared with SAVR, the SAPIEN-XT TAVR cohort had a significantly higher 5-year exposure adjusted incidence rates (per 100 patient-years) of SVD (1.61 ± 0.24% vs. 0.63 ± 0.16%), SVD-related BVF (0.58 ± 0.14% vs. 0.12 ± 0.07%), and all-cause (structural or nonstructural) BVF (0.81 ± 0.16% vs. 0.27 ± 0.10%) (p ≤ 0.01 for all). The 5-year rates of SVD (0.68 ± 0.18% vs. 0.60 ± 0.17%; p = 0.71), SVD-related BVF (0.29 ± 0.12% vs. 0.14 ± 0.08%; p = 0.25), and all-cause BVF (0.60 ± 0.15% vs. 0.32 ± 0.11%; p = 0.32) in SAPIEN 3 TAVR were not significantly different to a propensity score matched SAVR cohort. The 5-year rates of SVD and SVD-related BVF were significantly lower in SAPIEN 3 versus SAPIEN XT TAVR matched cohorts. CONCLUSIONS Compared with SAVR, the second-generation SAPIEN XT balloon-expandable valve has a higher 5-year rate of SVD, whereas the third-generation SAPIEN 3 has a rate of SVD that was not different from SAVR. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII A [PARTNERII A]; NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - PARTNER II - PARTNERII - S3 Intermediate [PARTNERII S3i]; NCT03222128).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2020.08.049

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 217

Metadata

Authors
Pibarot, P., Ternacle, J., Jaber, W. A., Salaun, E., Dahou, A., Asch, F. M., Weissman, N. J., Rodriguez, L., Xu, K., Annabi, M.-S., Guzzetti, E., Beaudoin, J., Bernier, M., Leipsic, J., Blanke, P., Clavel, M.-A., Rogers, E., Alu, M. C., Douglas, P. S., Makkar, R., Miller, D. C., Kapadia, S. R., Mack, M. J., Webb, J. G., Kodali, S. K., Smith, C. R., Herrmann, H. C., Thourani, V. H., Leon, M. B., & Hahn, R. T.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2020-10
Volume
76
Issue
16
Pages
1830-1843
ISSN
0735-1097 (ISSN-L)
OpenAlex
W3092536755
Cited by
217
References
2
FWCI
16.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Structural Deterioration of Transcatheter Versus Surgical Aortic Valve Bioprostheses in the PARTNER-2 Trial. https://app.cochat.ai/papers/10.1016/j.jacc.2020.08.049
The paper
Pibarot, P., Ternacle, J., Jaber, W. A., Salaun, E., Dahou, A., Asch, F. M., Weissman, N. J., Rodriguez, L., Xu, K., Annabi, M.-S., Guzzetti, E., Beaudoin, J., Bernier, M., Leipsic, J., Blanke, P., Clavel, M.-A., Rogers, E., Alu, M. C., Douglas, P. S., . . . Hahn, R. T. (2020). Structural Deterioration of Transcatheter Versus Surgical Aortic Valve Bioprostheses in the PARTNER-2 Trial. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2020.08.049

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.