The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Transcatheter Aortic-Valve Replacement in Low-Risk Patients at Five Years
Abstract
BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationProportional hazards tests and diagnostics based on weighted residuals
GRAMBSCH, P. M., & THERNEAU, T. M. (1994) · Biometrika · doi:10.1093/biomet/81.3.515 · Cited by 5,885
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehab395 · Cited by 5,685
Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients
Leon, M. B., Smith, C. R., Mack, M. J., Makkar, R. R., Svensson, L. G., Kodali, S. K., Thourani, V. H., Tuzcu, E. M., Miller, D. C., Herrmann, H. C., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1514616 · Cited by 5,053
Self-citationTranscatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
Mack, M. J., Leon, M. B., Thourani, V. H., Makkar, R., Kodali, S. K., Russo, M., Kapadia, S. R., Malaisrie, S. C., Cohen, D. J., Pibarot, P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1814052 · Cited by 4,847
Self-citationOtto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
Self-citationTranscatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients
Popma, J. J., Deeb, G. M., Yakubov, S. J., Mumtaz, M., Gada, H., O’Hair, D., Bajwa, T., Heiser, J. C., Merhi, W., Kleiman, N. S., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1816885 · Cited by 3,674
Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients
Reardon, M. J., Van Mieghem, N. M., Popma, J. J., Kleiman, N. S., Søndergaard, L., Mumtaz, M., Adams, D. H., Deeb, G. M., Maini, B., Gada, H., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1700456 · Cited by 3,009
Self-citationMack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60308-7 · Cited by 1,739
Self-citation
Cited by
Martin, S. S., Aday, A. W., Allen, N. B., Almarzooq, Z. I., Anderson, C. A. M., Arora, P., Avery, C. L., Baker-Smith, C. M., Bansal, N., Beaton, A. Z., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001303 · Cited by 1,080
2025 ESC/EACTS Guidelines for the management of valvular heart disease
Praz, F., Borger, M. A., Lanz, J., Marin-Cuartas, M., Abreu, A., Adamo, M., Ajmone Marsan, N., Barili, F., Bonaros, N., Cosyns, B., et al. (2025) · European Heart Journal · doi:10.1093/eurheartj/ehaf194 · Cited by 1,072
Transcatheter or surgical aortic valve implantation: 10-year outcomes of the NOTION trial
Thyregod, H. G. H., Jørgensen, T. H., Ihlemann, N., Steinbrüchel, D. A., Nissen, H., Kjeldsen, B. J., Petursson, P., De Backer, O., Olsen, P. S., & Søndergaard, L. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae043 · Cited by 383
Transcatheter or Surgical Treatment of Aortic-Valve Stenosis
Blankenberg, S., Seiffert, M., Vonthein, R., Baumgartner, H., Bleiziffer, S., Borger, M. A., Choi, Y.-H., Clemmensen, P., Cremer, J., Czerny, M., et al. (2024) · New England Journal of Medicine · doi:10.1056/nejmoa2400685 · Cited by 260
Age-stratified surgical aortic valve replacement for aortic stenosis
Mehta, C. K., Liu, T. X., Bonnell, L., Habib, R. H., Kaneko, T., Flaherty, J. D., Davidson, C. J., Thomas, J. D., Rigolin, V. H., Bonow, R. O., et al. (2024) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2024.01.013 · Cited by 27
Self-citation
Metadata
- Authors
- Mack, M. J., Leon, M. B., Thourani, V. H., Pibarot, P., Hahn, R. T., Genereux, P., Kodali, S. K., Kapadia, S. R., Cohen, D. J., Pocock, S. J., Lu, M., White, R., Szerlip, M., Ternacle, J., Malaisrie, S. C., Herrmann, H. C., Szeto, W. Y., Russo, M. J., Babaliaros, V., Smith, C. R., Blanke, P., Webb, J. G., & Makkar, R.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2023-11-23
- Volume
- 389
- Issue
- 21
- Pages
- 1949-1960
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W4387893182
- Cited by
- 635
- References
- 28
- FWCI
- 111.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transcatheter Aortic-Valve Replacement in Low-Risk Patients at Five Years. https://app.cochat.ai/papers/10.1056/nejmoa2307447
- The paper
- Mack, M. J., Leon, M. B., Thourani, V. H., Pibarot, P., Hahn, R. T., Genereux, P., Kodali, S. K., Kapadia, S. R., Cohen, D. J., Pocock, S. J., Lu, M., White, R., Szerlip, M., Ternacle, J., Malaisrie, S. C., Herrmann, H. C., Szeto, W. Y., Russo, M. J., Babaliaros, V., . . . Makkar, R. (2023). Transcatheter Aortic-Valve Replacement in Low-Risk Patients at Five Years. New England Journal of Medicine. https://doi.org/10.1056/nejmoa2307447
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.