Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 437

The DOI matches its Crossref record.

Transcatheter Edge-to-Edge Repair for Treatment of Tricuspid Regurgitation

Open access
Lurz, Philipp, von Bardeleben, Ralph Stephan, Weber, Marcel, Sitges, Marta, Sorajja, Paul, Hausleiter, Jörg, Denti, Paolo, Trochu, Jean-Noël, Nabauer, Michael, Tang, Gilbert H.L., Biaggi, Patric, Ying, Shih-Wa, Trusty, Phillip M., Dahou, Abdellaziz, Hahn, Rebecca T., Nickenig, Georg·2021·Journal of the American College of Cardiology

Abstract

BACKGROUND Tricuspid regurgitation (TR) is a frequent disease with a progressive increase in mortality as disease severity increases. Transcatheter therapies for treatment of TR may offer a safe and effective alternative to surgery in this high-risk population. OBJECTIVES The purpose of this report was to study the 1-year outcomes with the TriClip transcatheter tricuspid valve repair system, including repair durability, clinical benefit and safety. METHODS The TRILUMINATE trial (n = 85) is an international, prospective, single arm, multicenter study investigating safety and performance of the TriClip Tricuspid Valve Repair System in patients with moderate or greater TR. Echocardiographic assessment was performed by a core laboratory. RESULTS At 1 year, TR was reduced to moderate or less in 71% of subjects compared with 8% at baseline (p < 0.0001). Patients experienced significant clinical improvements in New York Heart Association (NYHA) functional class I/II (31% to 83%, p < 0.0001), 6-minute walk test (272.3 ± 15.6 to 303.2 ± 15.6 meters, p = 0.0023) and Kansas City Cardiomyopathy Questionnaire (KCCQ) score (improvement of 20 ± 2.61 points, p < 0.0001). Significant reverse right ventricular remodeling was observed in terms of size and function. The overall major adverse event rate and all-cause mortality were both 7.1% at 1 year. CONCLUSION Transcatheter tricuspid valve repair using the TriClip device was found to be safe and effective in patients with moderate or greater TR. The repair itself was durable at reducing TR at 1 year and was associated with a sustained and marked clinical benefit with low mortality after 1 year in a fragile population that was at high surgical risk. (TRILUMINATE Study With Abbott Transcatheter Clip Repair System in Patients With Moderate or Greater TR; NCT03227757).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2020.11.038

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 437

Metadata

Authors
Lurz, P., von Bardeleben, R. S., Weber, M., Sitges, M., Sorajja, P., Hausleiter, J., Denti, P., Trochu, J.-N., Nabauer, M., Tang, G. H. L., Biaggi, P., Ying, S.-W., Trusty, P. M., Dahou, A., Hahn, R. T., & Nickenig, G.
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2021-01
Volume
77
Issue
3
Pages
229-239
ISSN
0735-1097 (ISSN-L)
OpenAlex
W3124426946
Cited by
437
References
0
FWCI
50.71
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcatheter Edge-to-Edge Repair for Treatment of Tricuspid Regurgitation. https://app.cochat.ai/papers/10.1016/j.jacc.2020.11.038
The paper
Lurz, P., von Bardeleben, R. S., Weber, M., Sitges, M., Sorajja, P., Hausleiter, J., Denti, P., Trochu, J.-N., Nabauer, M., Tang, G. H. L., Biaggi, P., Ying, S.-W., Trusty, P. M., Dahou, A., Hahn, R. T., & Nickenig, G. (2021). Transcatheter Edge-to-Edge Repair for Treatment of Tricuspid Regurgitation. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2020.11.038

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.