Enhanced Detection and Prompt Diagnosis of Atrial Fibrillation Using Apple Watch
Abstract
Background Atrial fibrillation (AF), the most common cardiac arrhythmia, is a major cause of stroke and often remains undiagnosed due to its paroxysmal and frequently asymptomatic nature. Wearables provide a scalable, noninvasive screening tool. Objectives This trial evaluated new onset AF detection in patients at elevated stroke risk using remote smartwatch-based screening. Methods This prospective multicenter randomized controlled trial included patients ≥65 years with elevated stroke risk (CHA 2 DS 2-VASc ≥2 men, ≥3 women) from 2 secondary care centers in the Netherlands. Patients were randomized to 6-month (180-day) monitoring with a smartwatch with photoplethysmography and single-lead electrocardiogram (ECG) functions, or standard care. ECGs were reviewed remotely by an independent eHealth team within 24 hours. The primary outcome was new onset AF, defined as a confirmed episode lasting ≥30 seconds on single-lead ECG or standard ECG methods. Results Between November 2022 and December 2023, 437 patients were randomized (219 intervention, 218 control); the median age was 75 years, 46.7% were female and the median CHA 2 DS 2-VASc score was 3.0. New onset AF occurred in 21 (9.6%) patients of the intervention group and 5 (2.3%) patients of the control group (risk difference: 7.3 percentage points; 95% CI: 2.9-11.7 percentage points; P = 0.001; HR: 4.40; 95% CI: 1.66-11.66). Several asymptomatic AF episodes were detected only in the intervention group, while paroxysmal AF occurred in both groups. Conclusions This randomized controlled trial provides evidence that 6-month smartwatch-based AF screening enhances the detection rate of new onset AF compared with standard care in patients at elevated stroke risk. (Detection and Quantification of Atrial Fibrillation in High-risk Patients Using a Smartwatch Wearable [Apple Watch] [EQUAL]; NCT05686330).
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Perez, M. V., Mahaffey, K. W., Hedlin, H., Rumsfeld, J. S., Garcia, A., Ferris, T., Balasubramanian, V., Russo, A. M., Rajmane, A., Cheung, L., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1901183 · Cited by 1,917 · see citing works
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580 · see citing works
Steinhubl, S. R., Waalen, J., Edwards, A. M., Ariniello, L. M., Mehta, R. R., Ebner, G. S., Carter, C., Baca-Motes, K., Felicione, E., Sarich, T., et al. (2018) · JAMA · doi:10.1001/jama.2018.8102 · Cited by 539 · see citing works
Flagged first, then by citations
- Authors
- van Steijn, N. J., Blommestijn, I. S., Blok, S., Pepplinkhuizen, S., Somsen, G. A., Knops, R. E., Breukel, L., Tijssen, J. G. P., Tulevski, I. I., Croon, P. M., & Winter, M. M.
- Affiliations
- Amsterdam University Medical Centers (NL)
- Spaarne Gasthuis (NL)
- Yale University (US)
- Corresponding author
- Winter, Michiel M.
- ORCID
- Venue
- JACC
- Publisher
- Elsevier BV
- Published
- 2026-04
- Volume
- 87
- Issue
- 14
- Pages
- 1714-1728
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W7125375849
- Cited by
- 21
- References
- 3
- Citations by year
- 2026: 21
- FWCI
- 106.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American College of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Food and Drug Administration
- Apple
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- atrial fibrillation, Apple Watch, wearable devices, photoplethysmography, single-lead ECG, stroke risk, VASc score, asymptomatic atrial fibrillation, paroxysmal atrial fibrillation, remote ECG monitoring, early detection
- MeSH terms
- Wearable Electronic Devices, Digital Health, Remote Patient Monitoring, Aged, Aged, 80 and over, Atrial Fibrillation, Electrocardiography, Female, Humans, Male, Netherlands, Prospective Studies, Photoplethysmography, Stroke, Early Diagnosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review