Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The Electrical Isolation of the Left Atrial Posterior Wall in Catheter Ablation of Persistent Atrial Fibrillation

Open access
Lee, Jung Myung, Shim, Jaemin, Park, Junbeom, Yu, Hee Tae, Kim, Tae-Hoon, Park, Jin-Kyu, Uhm, Jae-Sun, Kim, Jin-Bae, Joung, Boyoung, Lee, Moon-Hyoung, Kim, Young-Hoon, Pak, Hui-Nam·2019·JACC: Clinical Electrophysiology

Abstract

OBJECTIVES This study explored whether complete electrical isolation of the left atrial (LA) posterior wall improves the rhythm outcome of catheter ablation of persistent atrial fibrillation (AF). BACKGROUND Although the STAR AF2 (Substrate and Trigger Ablation for Reduction of Atrial Fibrillation Trial Part II) proved no additional benefit of empirical extra-pulmonary vein (PV) LA ablation, the long-term recurrence rate after circumferential PV isolation (CPVI) alone remains high. METHODS We randomly assigned 217 patients with persistent AF (83.1% men, age 58.7 ± 10.8 years, 73.3% long-standing persistent AF) to ablation with CPVI alone (CPVI group) or CPVI with a POsterior wall Box Isolation (POBI group). The endpoint of the POBI group was the elimination of the posterior atrial potentials by roof and posterior inferior lines and touch-up focal ablation. RESULTS After a mean follow-up of 16.2 ± 8.8 months, the clinical recurrence rate did not significantly differ between the 2 groups (23.8% vs. 26.5%; p = 0.779) in the CPVI and POBI groups. The recurrence rate for atrial tachycardias (16.0% vs. 11.1%; p = 0.913) and cardioversion rates (6.7% vs. 13.7%; p = 0.093) to control clinical recurrences also did not significantly differ between the 2 groups. At the final follow-up, sinus rhythm was maintained without antiarrhythmic drug in 50.5% and 55.9% in the CPVI and POBI groups, respectively (p = 0.522). No significant difference was found in the major complication rates between the 2 groups, but the total ablation time was significantly longer in the POBI group (4,289 ± 1,837 s vs. 5,365 ± 2,358 s; p < 0.001). CONCLUSIONS In patients with persistent AF, an empirical complete POBI did not improve the rhythm outcome of catheter ablation or influence the type of recurrent atrial arrhythmia. (Comparison of Circumferential Pulmonary Vein Isolation Alone Versus Linear Ablation in Addition to Circumferential Pulmonary Vein Isolation for Catheter Ablation in Persistent Atrial Fibrillation: Prospective Randomized Controlled Trial; NCT02721121).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacep.2019.08.021

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 206

Metadata

Authors
Lee, J. M., Shim, J., Park, J., Yu, H. T., Kim, T.-H., Park, J.-K., Uhm, J.-S., Kim, J.-B., Joung, B., Lee, M.-H., Kim, Y.-H., & Pak, H.-N.
Venue
JACC: Clinical Electrophysiology
Publisher
Elsevier BV
Published
2019-11
Volume
5
Issue
11
Pages
1253-1261
ISSN
2405-500X (ISSN-L)
OpenAlex
W2982379625
Cited by
206
References
2
FWCI
16.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.