The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Pulsed Field Ablation in Patients With Persistent Atrial Fibrillation
Open accessAbstract
BACKGROUND: Unlike for paroxysmal atrial fibrillation (AF), pulmonary vein isolation (PVI) alone is considered insufficient for many patients with persistent AF. Adjunctive ablation of the left atrial posterior wall (LAPW) may improve outcomes, but is limited by both the difficulty of achieving lesion durability and concerns of damage to the esophagus-situated behind the LAPW. OBJECTIVES: This study sought to assess the safety and lesion durability of pulsed field ablation (PFA) for both PVI and LAPW ablation in persistent AF. METHODS: PersAFOne is a single-arm study evaluating biphasic, bipolar PFA using a multispline catheter for PVI and LAPW ablation under intracardiac echocardiographic guidance. A focal PFA catheter was used for cavotricuspid isthmus ablation. No esophageal protection strategy was used. Invasive remapping was mandated at 2 to 3 months to assess lesion durability. RESULTS: In 25 patients, acute PVI (96 of 96 pulmonary veins [PVs]; mean ablation time: 22 min; interquartile range [IQR]: 15 to 29 min) and LAPW ablation (24 of 24 patients; median ablation time: 10 min; IQR: 6 to 13 min) were 100% acutely successful with the multispline PFA catheter alone. Using the focal PFA catheter, acute cavotricuspid isthmus block was achieved in 13 of 13 patients (median: 9 min; IQR: 6 to 12 min). The median total procedure time was 125 min (IQR: 108 to 166 min) (including a median of 28 min [IQR: 25 to 33 min] for voltage mapping), with a median of 16 min (IQR: 12 to 23 min) fluoroscopy. Post-procedure esophagogastroduodenoscopy and repeat cardiac computed tomography revealed no mucosal lesions or PV narrowing, respectively. Invasive remapping demonstrated durable isolation (defined by entrance block) in 82 of 85 PVs (96%) and 21 of 21 LAPWs (100%) treated with the pentaspline catheter. In 3 patients, there was localized scar regression of the LAPW ablation, albeit without conduction breakthrough. CONCLUSIONS: The unique safety profile of PFA potentiated efficient, safe, and durable PVI and LAPW ablation. This extends the potential role of PFA beyond paroxysmal to persistent forms of AF. (Pulsed Fields for Persistent Atrial Fibrillation [PersAFOne]; NCT04170621).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
Kuck, K.-H., Brugada, J., Fürnkranz, A., Metzner, A., Ouyang, F., Chun, K. R. J., Elvan, A., Arentz, T., Bestehorn, K., Pocock, S. J., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1602014 · Cited by 1,950
Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation
Reddy, V. Y., Neuzil, P., Koruth, J. S., Petru, J., Funosako, M., Cochet, H., Sediva, L., Chovanec, M., Dukkipati, S. R., & Jais, P. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.04.021 · Cited by 700
Self-citationDi Biase, L., Burkhardt, J. D., Mohanty, P., Mohanty, S., Sanchez, J. E., Trivedi, C., Güneş, M., Gökoğlan, Y., Gianni, C., Horton, R. P., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.07.770 · Cited by 445
Pulmonary Vein Isolation Using the Visually Guided Laser Balloon
Dukkipati, S. R., Cuoco, F., Kutinsky, I., Aryana, A., Bahnson, T. D., Lakkireddy, D., Woollett, I., Issa, Z. F., Natale, A., & Reddy, V. Y. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.07.036 · Cited by 212
Self-citationLee, J. M., Shim, J., Park, J., Yu, H. T., Kim, T.-H., Park, J.-K., Uhm, J.-S., Kim, J.-B., Joung, B., Lee, M.-H., et al. (2019) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2019.08.021 · Cited by 206
Bai, R., Di Biase, L., Mohanty, P., Trivedi, C., Dello Russo, A., Themistoclakis, S., Casella, M., Santarelli, P., Fassini, G., Santangeli, P., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.08.019 · Cited by 195
Feasibility, Safety, and Efficacy of Posterior Wall Isolation During Atrial Fibrillation Ablation
Thiyagarajah, A., Kadhim, K., Lau, D. H., Emami, M., Linz, D., Khokhar, K. B., Munawar, D. A., Mishima, R. S., Malik, V., O’Shea, C., et al. (2019) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.118.007005 · Cited by 145
Douglas, Y. L., Jongbloed, M. R. M., DeRuiter, M. C., & Groot, A. C. G. (2010) · International Journal of Cardiology · doi:10.1016/j.ijcard.2010.07.004 · Cited by 103
Cited by
Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation
Reddy, V. Y., Gerstenfeld, E. P., Natale, A., Whang, W., Cuoco, F. A., Patel, C., Mountantonakis, S. E., Gibson, D. N., Harding, J. D., Ellis, C. R., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2307291 · Cited by 970
Self-citationPulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial
Verma, A., Haines, D. E., Boersma, L. V., Sood, N., Natale, A., Marchlinski, F. E., Calkins, H., Sanders, P., Packer, D. L., Kuck, K.-H., et al. (2023) · Circulation · doi:10.1161/circulationaha.123.063988 · Cited by 613
Pulsed Field Ablation of Paroxysmal Atrial Fibrillation
Reddy, V. Y., Dukkipati, S. R., Neuzil, P., Anic, A., Petru, J., Funasako, M., Cochet, H., Minami, K., Breskovic, T., Sikiric, I., et al. (2021) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2021.02.014 · Cited by 558
Self-citationTuragam, M. K., Neuzil, P., Schmidt, B., Reichlin, T., Neven, K., Metzner, A., Hansen, J., Blaauw, Y., Maury, P., Arentz, T., et al. (2023) · Circulation · doi:10.1161/circulationaha.123.064959 · Cited by 381
Self-citationSchmidt, B., Bordignon, S., Neven, K., Reichlin, T., Blaauw, Y., Hansen, J., Adelino, R., Ouss, A., Füting, A., Roten, L., et al. (2023) · Europace · doi:10.1093/europace/euad185 · Cited by 310
Metadata
- Authors
- Reddy, V. Y., Anic, A., Koruth, J., Petru, J., Funasako, M., Minami, K., Breskovic, T., Sikiric, I., Dukkipati, S. R., Kawamura, I., & Neuzil, P.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2020-09
- Volume
- 76
- Issue
- 9
- Pages
- 1068-1080
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W3080498817
- Cited by
- 418
- References
- 12
- FWCI
- 22.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulsed Field Ablation in Patients With Persistent Atrial Fibrillation. https://app.cochat.ai/papers/10.1016/j.jacc.2020.07.007
- The paper
- Reddy, V. Y., Anic, A., Koruth, J., Petru, J., Funasako, M., Minami, K., Breskovic, T., Sikiric, I., Dukkipati, S. R., Kawamura, I., & Neuzil, P. (2020). Pulsed Field Ablation in Patients With Persistent Atrial Fibrillation. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2020.07.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.