The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Performance of ACR Lung-RADS in a Clinical CT Lung Screening Program
Open accessAbstract
PURPOSE: The aim of this study was to assess the effect of applying ACR Lung-RADS in a clinical CT lung screening program on the frequency of positive and false-negative findings. METHODS: Consecutive, clinical CT lung screening examinations performed from January 2012 through May 2014 were retroactively reclassified using the new ACR Lung-RADS structured reporting system. All examinations had initially been interpreted by radiologists credentialed in structured CT lung screening reporting following the National Comprehensive Cancer Network's Clinical Practice Guidelines in Oncology: Lung Cancer Screening (version 1.2012), which incorporated positive thresholds modeled after those in the National Lung Screening Trial. The positive rate, number of false-negative findings, and positive predictive value were recalculated using the ACR Lung-RADS-specific positive solid/part-solid nodule diameter threshold of 6 mm and nonsolid (ground-glass) threshold of 2 cm. False negatives were defined as cases reclassified as benign under ACR Lung-RADS that were diagnosed with malignancies within 12 months of the baseline examination. RESULTS: A total of 2,180 high-risk patients underwent baseline CT lung screening during the study interval; no clinical follow-up was available in 577 patients (26%). ACR Lung-RADS reduced the overall positive rate from 27.6% to 10.6%. No false negatives were present in the 152 patients with >12-month follow-up reclassified as benign. Applying ACR Lung-RADS increased the positive predictive value for diagnosed malignancy in 1,603 patients with follow-up from 6.9% to 17.3%. CONCLUSIONS: The application of ACR Lung-RADS increased the positive predictive value in our CT lung screening cohort by a factor of 2.5, to 17.3%, without increasing the number of examinations with false-negative results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
The National Lung Screening Trial Research Team (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102873 · Cited by 11,064
Cited by
Breast Cancer, Version 4.2017, NCCN Clinical Practice Guidelines in Oncology
Gradishar, W. J., Anderson, B. O., Balassanian, R., Blair, S. L., Burstein, H. J., Cyr, A., Elias, A. D., Farrar, W. B., Forero, A., Giordano, S. H., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0012 · Cited by 1,609
Lung Cancer Screening, Version 3.2018, NCCN Clinical Practice Guidelines in Oncology
Wood, D. E., Kazerooni, E. A., Baum, S. L., Eapen, G. A., Ettinger, D. S., Hou, L., Jackman, D. M., Klippenstein, D., Kumar, R., Lackner, R. P., et al. (2018) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2018.0020 · Cited by 611
European position statement on lung cancer screening
Oudkerk, M., Devaraj, A., Vliegenthart, R., Henzler, T., Prosch, H., Heussel, C. P., Bastarrika, G., Sverzellati, N., Mascalchi, M., Delorme, S., et al. (2017) · The Lancet Oncology · doi:10.1016/s1470-2045(17)30861-6 · Cited by 587
Recommendations for Measuring Pulmonary Nodules at CT: A Statement from the Fleischner Society
Bankier, A. A., MacMahon, H., Goo, J. M., Rubin, G. D., Schaefer-Prokop, C. M., & Naidich, D. P. (2017) · Radiology · doi:10.1148/radiol.2017162894 · Cited by 347
NCCN Guidelines Insights: Kidney Cancer, Version 2.2020
Motzer, R. J., Jonasch, E., Michaelson, M. D., Nandagopal, L., Gore, J. L., George, S., Alva, A., Haas, N., Harrison, M. R., Plimack, E. R., et al. (2019) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2019.0054 · Cited by 287
Metadata
- Authors
- McKee, B. J., Regis, S. M., McKee, A. B., Flacke, S., & Wald, C.
- Venue
- Journal of the American College of Radiology
- Publisher
- Elsevier BV
- Published
- 2015-03
- Volume
- 12
- Issue
- 3
- Pages
- 273-276
- ISSN
- 1546-1440 (ISSN-L)
- OpenAlex
- W1965822150
- Cited by
- 241
- References
- 1
- FWCI
- 16.72
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of ACR Lung-RADS in a Clinical CT Lung Screening Program. https://app.cochat.ai/papers/10.1016/j.jacr.2014.08.004
- The paper
- McKee, B. J., Regis, S. M., McKee, A. B., Flacke, S., & Wald, C. (2015). Performance of ACR Lung-RADS in a Clinical CT Lung Screening Program. Journal of the American College of Radiology. https://doi.org/10.1016/j.jacr.2014.08.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.