The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Solvothermal synthesis of CuFe2O4 and Fe3O4 nanoparticles with high heating efficiency for magnetic hyperthermia application
Abstract
Abstract Magnetic nanoparticles with improved heating efficiency are required for an efficient magnetic hyperthermia therapy. In this study, monodisperse CuFe2O4 nanoparticles (NPs) with higher heat generation capability compared to Fe3O4 NPs were synthesized by a solvothermal method using triethylene glycol as solvent, reductant, and stabilizer. X-ray diffraction (XRD) analysis confirmed the single phase formation of CuFe2O4 and Fe3O4 NPs under experimental conditions. Fourier transform infrared spectroscopy (FT-IR) confirmed the presence of TREG molecules on the surface of both samples. Nanoparticles with spherical shape were observed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM) with an average particle size of 19.9 and 18.5 nm for CuFe2O4 and Fe3O4 NPs, respectively. The room temperature magnetic measurements indicated that both samples are in the vicinity of transition point from superparamagnetic to single-domain ferromagnetic state with a saturation magnetization of 53.1 and 58.8 emu/g for CuFe2O4 and Fe3O4 NPs, respectively. Moreover, CuFe2O4 NPs showed the lower anisotropy energy compared to Fe3O4 NPs, leading to the faster approach to saturation and slightly more rectangular hysteresis loop. The heating efficacy of the CuFe2O4 and Fe3O4 NPs were investigated under different safe alternating magnetic fields permissible for magnetic hyperthermia therapy (f = 120 kHz, H = 13, 16, and 19 kA/m). The maximum specific absorption rate (SAR) obtained for CuFe2O4 and Fe3O4 NPs were 44.9 and 18.5 W/g, respectively, at magnetic field intensity of 19 kA/m and frequency of 120 kHz. The two-fold increase in the SAR value of the CuFe2O4 NPs compared to the Fe3O4 NPs might be attributed to the tuning and better matching of their anisotropy energy with frequency and magnetic field intensity used in magnetic hyperthermia experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Renal clearance of quantum dots
Soo Choi, H., Liu, W., Misra, P., Tanaka, E., Zimmer, J. P., Itty Ipe, B., Bawendi, M. G., & Frangioni, J. V. (2007) · Nature Biotechnology · doi:10.1038/nbt1340 · Cited by 4,476
Cited by
A comprehensive review on various techniques used for synthesizing nanoparticles
Kumari, S., Raturi, S., Kulshrestha, S., Chauhan, K., Dhingra, S., András, K., Thu, K., Khargotra, R., & Singh, T. (2023) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2023.09.291 · Cited by 388
SOUFI, A., HAJJAOUI, H., ELMOUBARKI, R., ABDENNOURI, M., QOURZAL, S., & BARKA, N. (2021) · Applied Surface Science Advances · doi:10.1016/j.apsadv.2021.100145 · Cited by 302
Metadata
- Authors
- Fotukian, S. M., Barati, A., Soleymani, M., & Alizadeh, A. M.
- Venue
- Journal of Alloys and Compounds
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 816
- Pages
- 152548
- ISSN
- 0925-8388 (ISSN-L)
- OpenAlex
- W2979550889
- Cited by
- 198
- References
- 1
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Solvothermal synthesis of CuFe2O4 and Fe3O4 nanoparticles with high heating efficiency for magnetic hyperthermia application. https://app.cochat.ai/papers/10.1016/j.jallcom.2019.152548
- The paper
- Fotukian, S. M., Barati, A., Soleymani, M., & Alizadeh, A. M. (2020). Solvothermal synthesis of CuFe2O4 and Fe3O4 nanoparticles with high heating efficiency for magnetic hyperthermia application. Journal of Alloys and Compounds. https://doi.org/10.1016/j.jallcom.2019.152548
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.