The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Human Polymerized Hemoglobin for the Treatment of Hemorrhagic Shock when Blood Is Unavailable: The USA Multicenter Trial
Open accessAbstract
BACKGROUND: Human polymerized hemoglobin (PolyHeme, Northfield Laboratories) is a universally compatible oxygen carrier developed to treat life-threatening anemia. This multicenter phase III trial was the first US study to assess survival of patients resuscitated with a hemoglobin-based oxygen carrier starting at the scene of injury. STUDY DESIGN: Injured patients with a systolic blood pressure</=90 mmHg were randomized to receive field resuscitation with PolyHeme or crystalloid. Study patients continued to receive up to 6 U of PolyHeme during the first 12 hours postinjury before receiving blood. Control patients received blood on arrival in the trauma center. This trial was conducted as a dual superiority/noninferiority primary end point. RESULTS: Seven hundred fourteen patients were enrolled at 29 urban Level I trauma centers (79% men; mean age 37.1 years). Injury mechanism was blunt trauma in 48%, and median transport time was 26 minutes. There was no significant difference between day 30 mortality in the as-randomized (13.4% PolyHeme versus 9.6% control) or per-protocol (11.1% PolyHeme versus 9.3% control) cohorts. Allogeneic blood use was lower in the PolyHeme group (68% versus 50% in the first 12 hours). The incidence of multiple organ failure was similar (7.4% PolyHeme versus 5.5% control). Adverse events (93% versus 88%; p=0.04) and serious adverse events (40% versus 35%; p=0.12), as anticipated, were frequent in the PolyHeme and control groups, respectively. Although myocardial infarction was reported by the investigators more frequently in the PolyHeme group (3% PolyHeme versus 1% control), a blinded committee of experts reviewed records of all enrolled patients and found no discernable difference between groups. CONCLUSIONS: Patients resuscitated with PolyHeme, without stored blood for up to 6 U in 12 hours postinjury, had outcomes comparable with those for the standard of care. Although there were more adverse events in the PolyHeme group, the benefit-to-risk ratio of PolyHeme is favorable when blood is needed but not available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Multiple Testing Procedure for Clinical Trials
O'Brien, P. C., & Fleming, T. R. (1979) · Biometrics · doi:10.2307/2530245 · Cited by 3,311
Discrete sequential boundaries for clinical trials
GORDON LAN, K. K., & DEMETS, D. L. (1983) · Biometrika · doi:10.1093/biomet/70.3.659 · Cited by 2,310
Bickell, W. H., Wall, M. J., Pepe, P. E., Martin, R. R., Ginger, V. F., Allen, M. K., & Mattox, K. L. (1994) · New England Journal of Medicine · doi:10.1056/nejm199410273311701 · Cited by 2,151
Group sequential methods in the design and analysis of clinical trials
POCOCK, S. J. (1977) · Biometrika · doi:10.1093/biomet/64.2.191 · Cited by 1,831
Discrepancies between Meta-Analyses and Subsequent Large Randomized, Controlled Trials
LeLorier, J., Grégoire, G., Benhaddad, A., Lapierre, J., & Derderian, F. (1997) · New England Journal of Medicine · doi:10.1056/nejm199708213370806 · Cited by 1,171
Blood Flow Regulation by S -Nitrosohemoglobin in the Physiological Oxygen Gradient
Stamler, J. S., Jia, L., Eu, J. P., McMahon, T. J., Demchenko, I. T., Bonaventura, J., Gernert, K., & Piantadosi, C. A. (1997) · Science · doi:10.1126/science.276.5321.2034 · Cited by 1,050
Causes of Death in U.S. Special Operations Forces in the Global War on Terrorism: 2001–2004
Holcomb, J. B., McMullin, N. R., Pearse, L., Caruso, J., Wade, C. E., Oetjen-Gerdes, L., Champion, H. R., Lawnick, M., Farr, W., Rodriguez, S., et al. (2007) · Annals of Surgery · doi:10.1097/01.sla.0000259433.03754.98 · Cited by 706
Natanson, C., Kern, S. J., Lurie, P., Banks, S. M., & Wolfe, S. M. (2008) · JAMA · doi:10.1001/jama.299.19.jrv80007 · Cited by 622
Blood Transfusion: An Independent Risk Factor for Postinjury Multiple Organ Failure
Moore, F. A. (1997) · Archives of Surgery · doi:10.1001/archsurg.1997.01430300062013 · Cited by 562
Self-citationCarson, J. L., Noveck, H., Berlin, J. A., & Gould, S. A. (2002) · Transfusion · doi:10.1046/j.1537-2995.2002.00123.x · Cited by 544
Self-citation
Cited by
Holcomb, J. B., Tilley, B. C., Baraniuk, S., Fox, E. E., Wade, C. E., Podbielski, J. M., del Junco, D. J., Brasel, K. J., Bulger, E. M., Callcut, R. A., et al. (2015) · JAMA · doi:10.1001/jama.2015.12 · Cited by 2,526
Self-citationMoore, E. E., Moore, H. B., Kornblith, L. Z., Neal, M. D., Hoffman, M., Mutch, N. J., Schöchl, H., Hunt, B. J., & Sauaia, A. (2021) · Nature Reviews Disease Primers · doi:10.1038/s41572-021-00264-3 · Cited by 823
Self-citationClinical practice guideline: Red blood cell transfusion in adult trauma and critical care*
Napolitano, L. M., Kurek, S., Luchette, F. A., Corwin, H. L., Barie, P. S., Tisherman, S. A., Hebert, P. C., Anderson, G. L., Bard, M. R., Bromberg, W., et al. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b39f1b · Cited by 551
Self-citationClinical applications of indocyanine green (ICG) enhanced fluorescence in laparoscopic surgery
Boni, L., David, G., Mangano, A., Dionigi, G., Rausei, S., Spampatti, S., Cassinotti, E., & Fingerhut, A. (2015) · Surgical Endoscopy · doi:10.1007/s00464-014-3895-x · Cited by 548
Dutton, R. P., Stansbury, L. G., Leone, S., Kramer, E., Hess, J. R., & Scalea, T. M. (2010) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/ta.0b013e3181bbfe2a · Cited by 411
Metadata
- Authors
- Moore, E. E., Moore, F. A., Fabian, T. C., Bernard, A. C., Fulda, G. J., Hoyt, D. B., Duane, T. M., Weireter, L. J., Gomez, G. A., Cipolle, M. D., Rodman, G. H., Malangoni, M. A., Hides, G. A., Omert, L. A., & Gould, S. A.
- Venue
- Journal of the American College of Surgeons
- Published
- 2009-01
- Volume
- 208
- Issue
- 1
- Pages
- 1-13
- ISSN
- 1072-7515 (ISSN-L)
- OpenAlex
- W2090650515
- Cited by
- 259
- References
- 33
- FWCI
- 15.55
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human Polymerized Hemoglobin for the Treatment of Hemorrhagic Shock when Blood Is Unavailable: The USA Multicenter Trial. https://app.cochat.ai/papers/10.1016/j.jamcollsurg.2008.09.023
- The paper
- Moore, E. E., Moore, F. A., Fabian, T. C., Bernard, A. C., Fulda, G. J., Hoyt, D. B., Duane, T. M., Weireter, L. J., Gomez, G. A., Cipolle, M. D., Rodman, G. H., Malangoni, M. A., Hides, G. A., Omert, L. A., & Gould, S. A. (2009). Human Polymerized Hemoglobin for the Treatment of Hemorrhagic Shock when Blood Is Unavailable: The USA Multicenter Trial. Journal of the American College of Surgeons. https://doi.org/10.1016/j.jamcollsurg.2008.09.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.