Effect of Mesh Type and Position on Subsequent Abdominal Operations after Incisional Hernia Repair
The DOI matches its Crossref record.
Abstract
BACKGROUND: The frequency of subsequent abdominal operations (SAO) and complications attributable to earlier ventral incisional hernia repair (VIHR) are unknown. We examined the effect of repair type and technique on the difficulty and complications of subsequent surgery. STUDY DESIGN: A cohort of VIHRs at 16 Veterans Affairs hospitals between 1998 and 2002 was examined for postrepair abdominal operation by chart review. The primary independent variable was type and technique of the index VIHR: suture or mesh repair stratified by mesh type and position in relation to abdominal wall musculature. Subsequent surgery characteristics including operative time, inadvertent enterotomy, mesh removal, and length of postoperative stay were determined by chart review. Regression modeling was used to adjust for potential confounding variables. RESULTS: At a median of 80 months after VIHR in 1,444 patients, 366 (25.3%) experienced SAO. Nearly two-thirds of these involved rerepair of the VIHR with or without a concomitant procedure. Mesh removal was significantly more likely in expanded polytetrafluoroethylene repairs as compared with polypropylene repairs, regardless of technique (odds ratio = 3.6; p = 0.01). On multivariable regression modeling, polypropylene underlay (p = 0.03) and inlay (p = 0.001) and absorbable/biologic mesh (p = 0.05) significantly increased operative time for SAO. Repair type, mesh type, or position had no significant effect on risk of inadvertent enterotomy during the SAO (p≥0.27). CONCLUSIONS: Subsequent abdominal operations after VIHR are common. Underlay or inlay polypropylene mesh increases SAO operative time, but there was no increased risk of intestinal injury. Earlier repair with expanded polytetrafluoroethylene did not increase operative time, but there was equivalent risk for intestinal injury and increased risk for mesh removal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mesh location in open ventral hernia repair: a systematic review and network meta-analysis
Holihan, J. L., Nguyen, D. H., Nguyen, M. T., Mo, J., Kao, L. S., & Liang, M. K. (2016) · World Journal of Surgery · doi:10.1007/s00268-015-3252-9 · Cited by 314
Nomenclature in Abdominal Wall Hernias: Is It Time for Consensus?
Parker, S. G., Wood, C. P. J., Sanders, D. L., & Windsor, A. C. J. (2017) · World Journal of Surgery · doi:10.1007/s00268-017-4037-0 · Cited by 40
“For example, intra-abdominal mesh exposed to abdominal viscera increases the risk of adhesions, bowel obstruction and fistula formation [26, 27]; onlay mesh placement is associated with higher wound infection rates [15, 17] and hernia recurrence rates are reduced with the mesh in the retro-rectus (sublay) position [17…”
Background
Metadata
- Authors
- Snyder, C. W., Graham, L. A., Gray, S. H., Vick, C. C., & Hawn, M. T.
- Venue
- Journal of the American College of Surgeons
- Published
- 2011-04
- Volume
- 212
- Issue
- 4
- Pages
- 496-502
- ISSN
- 1072-7515 (ISSN-L)
- OpenAlex
- W2092409891
- Cited by
- 60
- References
- 0
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Mesh Type and Position on Subsequent Abdominal Operations after Incisional Hernia Repair. https://app.cochat.ai/papers/10.1016/j.jamcollsurg.2010.12.004
- The paper
- Snyder, C. W., Graham, L. A., Gray, S. H., Vick, C. C., & Hawn, M. T. (2011). Effect of Mesh Type and Position on Subsequent Abdominal Operations after Incisional Hernia Repair. Journal of the American College of Surgeons. https://doi.org/10.1016/j.jamcollsurg.2010.12.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.