Vortex-assisted ionic liquid microextraction coupled to flame atomic absorption spectrometry for determination of trace levels of cadmium in real samples
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A simple and rapid vortex assisted ionic liquid based liquid-liquid microextraction technique (VALLME) was proposed for preconcentration of trace levels of cadmium. According to this method, the extraction solvent was dispersed into the aqueous samples by the assistance of vortex agitator. Cadmium preconcentration was mediated by chelation with the 8-hydroxyquinoline (oxine) reagent and an IL, 1-octyl-3-methylimidazolium hexafluorophosphate ([Omim][PF6]) was chosen as the extraction solvent to extract the hydrophobic complex. Several variables such as sample pH, concentration of oxine, volume of [Omim][PF6] and extraction time were investigated in details and optimum conditions were selected. Under the optimum conditions, the limit of detection (LOD) was 2.9 μg L(-1) for Cd (ІІ) and relative standard deviation (RSD%) for five replicate determinations of 125 μg L(-1) was 4.1%. The method was successfully applied to the determination of cadmium in tap water, apple and rice samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Temperature-controlled ionic liquid dispersive liquid phase micro-extraction
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.103 · Cited by 303 · cited 2×
“Several extraction methods have been reported based on ionic liquids, such as ionic liquid-based headspace liquid phase microextraction [24], ionic liquid-based single-drop microextraction [25,26], ionic liquid-based headspace singledrop microextraction [27], cold induced aggregation microextraction [28] and temperatu…”
Method
Cited by
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Fundamentals of Ionic Liquids: From Chemistry to Applications
MacFarlane, D. R., Kar, M., & Pringle, J. M. (2017) · Wiley eBooks · doi:10.1002/9783527340033 · Cited by 197
Zounr, R. A., Tuzen, M., Deligonul, N., & Khuhawar, M. Y. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.01.167 · Cited by 127
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
“9 mg L¡1 (1245) Cd Urine, blood, serum IL-DLLME-BE ETAAS 5 ng L¡1 (1246) Cd Vegetable, water SM-DLLME FAAS 0.”
Soylak, M., & Yilmaz, E. (2015) · Analytical Letters · doi:10.1080/00032719.2014.949732 · Cited by 42
“The limit of detection obtained in this work was generally lower than previous techniques (Doner and Ege 2005; Ghaedi et al. 2009; Soylak and Unsal 2012; Chamsaz et al. 2013; Khan, Kazi, and Soylak 2014).”
ResultSorouraddin, S. M., Farajzadeh, M. A., Dastoori, H., & Okhravi, T. (2021) · International Journal of Environmental Analytical Chemistry · doi:10.1080/03067319.2019.1686144 · Cited by 42
Metadata
- Authors
- Chamsaz, M., Atarodi, A., Eftekhari, M., Asadpour, S., & Adibi, M.
- Venue
- Journal of Advanced Research
- Publisher
- Elsevier BV
- Published
- 2013-01
- Volume
- 4
- Issue
- 1
- Pages
- 35-41
- ISSN
- 2090-1224 (ISSN-L)
- 2090-1232
- OpenAlex
- W2170825719
- Cited by
- 92
- References
- 2
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.