The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Three-dimensional visualization of protein expression in mouse brain structures using imaging mass spectrometry
Abstract
We have developed a method to visualize matrix-assisted laser desorption ionization imaging mass spectrometry (MALDI IMS) data aligned with optically determinable tissue structures in three dimensions. Details of the methodology are exemplified using the 3-D reconstruction of myelin basic protein (MBP) in the corpus callosum of a mouse brain. In this procedure, optical images obtained from serial coronal sections are first aligned to each other to reconstruct a surface of the corpus callosum from segmented contours of the aligned images. The MALDI IMS data are then coregistered to the optical images and superimposed into the surface to create the final 3-D visualization. Correlating proteomic data with anatomical structures provides a more comprehensive understanding of healthy and pathological brain functions, and holds promise to be utilized in more complex anatomical arrangements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Reconstruction and representation of 3D objects with radial basis functions
Carr, J. C., Beatson, R. K., Cherrie, J. B., Mitchell, T. J., Fright, W. R., McCallum, B. C., & Evans, T. R. (2001) · Proceedings of the 28th annual conference on Computer graphics and interactive techniques · doi:10.1145/383259.383266 · Cited by 1,852
Cited by
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Norris, J. L., & Caprioli, R. M. (2013) · Chemical Reviews · doi:10.1021/cr3004295 · Cited by 696
Self-citationDeininger, S.-O., Ebert, M. P., Fütterer, A., Gerhard, M., & Röcken, C. (2008) · Journal of Proteome Research · doi:10.1021/pr8005777 · Cited by 266
Integrating spatially resolved three-dimensional MALDI IMS with in vivo magnetic resonance imaging
Sinha, T. K., Khatib-Shahidi, S., Yankeelov, T. E., Mapara, K., Ehtesham, M., Cornett, D. S., Dawant, B. M., Caprioli, R. M., & Gore, J. C. (2008) · Nature Methods · doi:10.1038/nmeth1147 · Cited by 168
Self-citation
Metadata
- Authors
- Crecelius, A. C., Cornett, D. S., Caprioli, R. M., Williams, B., Dawant, B. M., & Bodenheimer, B.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-07-01
- Volume
- 16
- Issue
- 7
- Pages
- 1093-1099
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2072645055
- Cited by
- 162
- References
- 2
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional visualization of protein expression in mouse brain structures using imaging mass spectrometry. https://app.cochat.ai/papers/10.1016/j.jasms.2005.02.026
- The paper
- Crecelius, A. C., Cornett, D. S., Caprioli, R. M., Williams, B., Dawant, B. M., & Bodenheimer, B. (2005). Three-dimensional visualization of protein expression in mouse brain structures using imaging mass spectrometry. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/j.jasms.2005.02.026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.