The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Semi-automated data processing of hydrogen exchange mass spectra using HX-Express
Abstract
A Microsoft Excel utility, HX-Express, that significantly accelerates the analysis of hydrogen exchange mass spectrometry data is described. HX-Express generates deuterium uptake and peak width plots from peaks in mass spectral data. Data analysis is intentionally semi-automated, requiring that the user find the peaks to be analyzed. The peaks are entered in the form of x, y lists of m/z versus intensity or can be directly imported from Waters MassLynx software. Analysis of data with HX-Express provides the same results as manual data processing but is substantially faster. In addition to speed, HX-Express provides and preserves visual and numeric displays of the analysis process for quality control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogen exchange mass spectrometry for the analysis of protein dynamics
Wales, T. E., & Engen, J. R. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20064 · Cited by 862
Self-citationWeis, D. D., Wales, T. E., Engen, J. R., Hotchko, M., & Ten Eyck, L. F. (2006) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.05.014 · Cited by 237
Self-citationAutomated extraction of backbone deuteration levels from amide H/2H mass spectrometry experiments
Hotchko, M., Anand, G. S., Komives, E. A., & Eyck, L. F. T. (2006) · Protein Science · doi:10.1110/ps.051774906 · Cited by 81
Hydrogen/Deuterium Exchange Mass Spectrometry for Investigating Protein-Ligand Interactions
Garcia, R. A., Pantazatos, D., & Villarreal, F. J. (2004) · Assay and Drug Development Technologies · doi:10.1089/154065804322966342 · Cited by 64
Cited by
Walls, A. C., Fiala, B., Schäfer, A., Wrenn, S., Pham, M. N., Murphy, M., Tse, L. V., Shehata, L., O’Connor, M. A., Chen, C., et al. (2020) · Cell · doi:10.1016/j.cell.2020.10.043 · Cited by 532
Marcandalli, J., Fiala, B., Ols, S., Perotti, M., de van der Schueren, W., Snijder, J., Hodge, E., Benhaim, M., Ravichandran, R., Carter, L., et al. (2019) · Cell · doi:10.1016/j.cell.2019.01.046 · Cited by 448
Post-translational Modifications Differentially Affect IgG1 Conformation and Receptor Binding
Houde, D., Peng, Y., Berkowitz, S. A., & Engen, J. R. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m900540-mcp200 · Cited by 393
Self-citationQuadrivalent influenza nanoparticle vaccines induce broad protection
Boyoglu-Barnum, S., Ellis, D., Gillespie, R. A., Hutchinson, G. B., Park, Y.-J., Moin, S. M., Acton, O. J., Ravichandran, R., Murphy, M., Pettie, D., et al. (2021) · Nature · doi:10.1038/s41586-021-03365-x · Cited by 304
HDX Workbench: Software for the Analysis of H/D Exchange MS Data
Pascal, B. D., Willis, S., Lauer, J. L., Landgraf, R. R., West, G. M., Marciano, D., Novick, S., Goswami, D., Chalmers, M. J., & Griffin, P. R. (2012) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-012-0419-6 · Cited by 293
Metadata
- Authors
- Weis, D. D., Engen, J. R., & Kass, I. J.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-12-01
- Volume
- 17
- Issue
- 12
- Pages
- 1700-1703
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W1967147564
- Cited by
- 258
- References
- 4
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.