Increasing charge while preserving noncovalent protein complexes for ESI-MS
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Increased multiple charging of native proteins and noncovalent protein complexes is observed in electrospray ionization (ESI) mass spectra obtained from nondenaturing protein solutions containing up to 1% (vol/vol) m-nitrobenzyl alcohol (m-NBA). The increases in charge ranged from 8% for the 690 kDa alpha(7)beta(7)beta(7)alpha(7) 20S proteasome complex to 48% additional charge for the zinc-bound 29 kDa carbonic anhydrase-II protein. No dissociation of the noncovalently bound ligands/subunits was observed upon the addition of m-NBA. It is not clear if the enhanced charging is related to altered surface tension as proposed in the "supercharging" model of Iavarone and Williams (Iavarone, A. T.; Williams, E. R. J. Am. Chem. Soc.2003, 125, 2319-2327). However, more highly charged noncovalent protein complexes have utility in relaxing slightly the mass-to-charge (m/z) requirements of the mass spectrometer for detection and will be effective for enhancing the efficiency for tandem mass spectrometry studies of protein complexes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634 · cited 1×
“Ahallmark of electrospray ionization (ESI) for the mass spectrometric analysis of large biomolecules is the multiple charging phenomenon described by the early work of John Fenn and others [1].”
Cited by
Hall, Z., Politis, A., Bush, M. F., Smith, L. J., & Robinson, C. V. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2096859 · Cited by 267
Top‐down proteomics in health and disease: Challenges and opportunities
Gregorich, Z. R., & Ge, Y. (2014) · PROTEOMICS · doi:10.1002/pmic.201300432 · Cited by 217
Belov, M. E., Damoc, E., Denisov, E., Compton, P. D., Horning, S., Makarov, A. A., & Kelleher, N. L. (2013) · Analytical Chemistry · doi:10.1021/ac4029328 · Cited by 175
Zhou, M., Dagan, S., & Wysocki, V. H. (2013) · The Analyst · doi:10.1039/c2an36525a · Cited by 92
Valeja, S. G., Kaiser, N. K., Xian, F., Hendrickson, C. L., Rouse, J. C., & Marshall, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac202429c · Cited by 67
Metadata
- Authors
- Lomeli, S. H., Yin, S., Ogorzalek Loo, R. R., & Loo, J. A.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-11-27
- Volume
- 20
- Issue
- 4
- Pages
- 593-596
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2058794436
- Cited by
- 144
- References
- 1
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Increasing charge while preserving noncovalent protein complexes for ESI-MS. https://app.cochat.ai/papers/10.1016/j.jasms.2008.11.013
- The paper
- Lomeli, S. H., Yin, S., Ogorzalek Loo, R. R., & Loo, J. A. (2009). Increasing charge while preserving noncovalent protein complexes for ESI-MS. Journal of the American Society for Mass Spectrometry. https://doi.org/10.1016/j.jasms.2008.11.013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.