Evaluating the effects of machine pre-annotation and an interactive annotation interface on manual de-identification of clinical text
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The Health Insurance Portability and Accountability Act (HIPAA) Safe Harbor method requires removal of 18 types of protected health information (PHI) from clinical documents to be considered "de-identified" prior to use for research purposes. Human review of PHI elements from a large corpus of clinical documents can be tedious and error-prone. Indeed, multiple annotators may be required to consistently redact information that represents each PHI class. Automated de-identification has the potential to improve annotation quality and reduce annotation time. For instance, using machine-assisted annotation by combining de-identification system outputs used as pre-annotations and an interactive annotation interface to provide annotators with PHI annotations for "curation" rather than manual annotation from "scratch" on raw clinical documents. In order to assess whether machine-assisted annotation improves the reliability and accuracy of the reference standard quality and reduces annotation effort, we conducted an annotation experiment. In this annotation study, we assessed the generalizability of the VA Consortium for Healthcare Informatics Research (CHIR) annotation schema and guidelines applied to a corpus of publicly available clinical documents called MTSamples. Specifically, our goals were to (1) characterize a heterogeneous corpus of clinical documents manually annotated for risk-ranked PHI and other annotation types (clinical eponyms and person relations), (2) evaluate how well annotators apply the CHIR schema to the heterogeneous corpus, (3) compare whether machine-assisted annotation (experiment) improves annotation quality and reduces annotation time compared to manual annotation (control), and (4) assess the change in quality of reference standard coverage with each added annotator's annotations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SUS: A 'Quick and Dirty' Usability Scale
(1996) · Usability Evaluation In Industry · doi:10.1201/9781498710411-35 · Cited by 8,989
Automated de-identification of free-text medical records
Neamatullah, I., Douglass, M. M., Lehman, L.-W. H., Reisner, A., Villarroel, M., Long, W. J., Szolovits, P., Moody, G. B., Mark, R. G., & Clifford, G. D. (2008) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-8-32 · Cited by 413
Cited by
De-identification of patient notes with recurrent neural networks
Dernoncourt, F., Lee, J. Y., Uzuner, O., & Szolovits, P. (2017) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocw156 · Cited by 378
A study of deep learning methods for de-identification of clinical notes in cross-institute settings
Yang, X., Lyu, T., Li, Q., Lee, C.-Y., Bian, J., Hogan, W. R., & Wu, Y. (2019) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-019-0935-4 · Cited by 73
Levy, A., Agrawal, M., Satyanarayan, A., & Sontag, D. (2021) · Proceedings of the 2021 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411764.3445522 · Cited by 73
“Past literature has also examined effects of pre-annotation on performance, both in standard NLP and clinical settings, but these have had mixed conclusions on the bias induced and the resulting time savings [9, 13, 27, 45].”
BackgroundA dataset of 200 structured product labels annotated for adverse drug reactions
Demner-Fushman, D., Shooshan, S. E., Rodriguez, L., Aronson, A. R., Lang, F., Rogers, W., Roberts, K., & Tonning, J. (2018) · Scientific Data · doi:10.1038/sdata.2018.1 · Cited by 68
“…fi ed ADRs that can be manually edited, we chose to annotate the ADRs completely manually (i.e., from scratch) to avoid bias, e.g., missing the ADRs unmarked in the pre-annotation process 7,8 , as well as potential slow-down due to too many false-positives generated by a pre-annotation tool 9 .”
An Empirical Study of Clinical Note Generation from Doctor-Patient Encounters
Ben Abacha, A., Yim, W.-W., Fan, Y., & Lin, T. (2023) · Proceedings of the 17th Conference of the European Chapter of the Association for Computational Linguistics · doi:10.18653/v1/2023.eacl-main.168 · Cited by 54
Reeves, R. M., Christensen, L., Brown, J. R., Conway, M., Levis, M., Gobbel, G. T., Shah, R. U., Goodrich, C., Ricket, I., Minter, F., et al. (2021) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2021.103851 · Cited by 45
Self-citation
Metadata
- Authors
- South, B. R., Mowery, D., Suo, Y., Leng, J., Ferrández, Ó., Meystre, S. M., & Chapman, W. W.
- Venue
- Journal of Biomedical Informatics
- Publisher
- Elsevier BV
- Published
- 2014-08
- Volume
- 50
- Pages
- 162-172
- ISSN
- 1532-0464 (ISSN-L)
- OpenAlex
- W1972477581
- Cited by
- 59
- References
- 2
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.