The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Non-Newtonian blood flow in human right coronary arteries: steady state simulations
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Biomechanics: Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138285 · Cited by 2,769
Ku, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707
Caro, C. G., Fitz-Gerald, J. M., & Schroter, R. C. (1971) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1971.0019 · Cited by 1,357
Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients
FRY, D. L. (1968) · Circulation Research · doi:10.1161/01.res.22.2.165 · Cited by 1,238
The Fluid Mechanics of Large Blood Vessels
Pedley, T. J., & Fung, Y. C. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138235 · Cited by 910
Flow patterns and spatial distribution of atherosclerotic lesions in human coronary arteries.
Asakura, T., & Karino, T. (1990) · Circulation Research · doi:10.1161/01.res.66.4.1045 · Cited by 856
Cho, Y. I., & Kensey, K. R. (1991) · Biorheology · doi:10.3233/bir-1991-283-415 · Cited by 823
Ck, F. (1970) · PubMed · Cited by 641
Berger, S. A., & Jou, L.-D. (2000) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.32.1.347 · Cited by 502
Cited by
Wall Shear Stress: Theoretical Considerations and Methods of Measurement
Katritsis, D., Kaiktsis, L., Chaniotis, A., Pantos, J., Efstathopoulos, E. P., & Marmarelis, V. (2007) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2006.11.001 · Cited by 346
Razavi, A., Shirani, E., & Sadeghi, M. R. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.04.023 · Cited by 257
Vascular Dynamics of a Shape Memory Polymer Foam Aneurysm Treatment Technique
Ortega, J., Maitland, D., Wilson, T., Tsai, W., Savaş, Ö., & Saloner, D. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9358-y · Cited by 57
Metadata
- Authors
- Johnston, B. M., Johnston, P. R., Corney, S., & Kilpatrick, D.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2004-05
- Volume
- 37
- Issue
- 5
- Pages
- 709-720
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2039195990
- Cited by
- 689
- References
- 18
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-Newtonian blood flow in human right coronary arteries: steady state simulations. https://app.cochat.ai/papers/10.1016/j.jbiomech.2003.09.016
- The paper
- Johnston, B. M., Johnston, P. R., Corney, S., & Kilpatrick, D. (2004). Non-Newtonian blood flow in human right coronary arteries: steady state simulations. Journal of Biomechanics. https://doi.org/10.1016/j.jbiomech.2003.09.016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.