The DOI matches its Crossref record.
Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients
Open accessAbstract
The purpose of this study is to quantify the acute changes in endothelial histology that are associated with an induced increase in blood velocity. A nontraumatic intra-aortic device was designed to produce a rapid convergence of the aortic blood stream into a narrow channel along the ventral aspect of the thoracic aorta in dogs. The endothelial surface overlying this channel was exposed to a broad range of surface shearing stress by the accelerated blood flow. Techniques were developed to quantify the resulting distribution of shearing stress so that the stress to which the endothelial surface was exposed at every point along the channel could be determined. Special histologic techniques were developed using formalin fixation and gelatin embedding of the tissue so that endothelial cytology could be studied and criteria for normal cells established. Using these criteria, cell counts were done to establish the "normal" endothelial cell population density as a function of stress exposure. The stress corresponding to the mode of these cell density distribution curves was defined as the acute yield stress (τ c ). The acute yield stress for endothelial cells was found to be 379±85 ( SD ) dynes/cm 2 . Exposure to stress in excess of this value for periods as short as one hour resulted in marked deterioration of the endothelial surface consisting of endothelial cytoplasmic swelling, cell deformation, cell disintegration, and finally dissolution and erosion of cell substance. The relationship of these events to cellular rheology and interfacial chemistry is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Image-Based Computational Fluid Dynamics Modeling in Realistic Arterial Geometries
Steinman, D. A. (2002) · Annals of Biomedical Engineering · doi:10.1114/1.1467679 · Cited by 381
Hydrodynamic effects on animal cells grown in microcarrier cultures
Croughan, M. S., Hamel, J., & Wang, D. I. C. (1987) · Biotechnology and Bioengineering · doi:10.1002/bit.260290117 · Cited by 371
Wentzel, J. J., Chatzizisis, Y. S., Gijsen, F. J. H., Giannoglou, G. D., Feldman, C. L., & Stone, P. H. (2012) · Cardiovascular Research · doi:10.1093/cvr/cvs217 · Cited by 353
Milner, J. S., Moore, J. A., Rutt, B. K., & Steinman, D. A. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70210-1 · Cited by 276
The shear stress of it all: the cell membrane and mechanochemical transduction
White, C. R., & Frangos, J. A. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2128 · Cited by 255
Metadata
- Authors
- FRY, D. L.
- Venue
- Circulation Research
- Published
- 1968-02
- Volume
- 22
- Issue
- 2
- Pages
- 165-197
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W1986161881
- Cited by
- 1,238
- References
- 0
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients. https://app.cochat.ai/papers/10.1161/01.res.22.2.165
- The paper
- FRY, D. L. (1968). Acute Vascular Endothelial Changes Associated with Increased Blood Velocity Gradients. Circulation Research. https://doi.org/10.1161/01.res.22.2.165
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.