The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using ‘interventional’ MRI
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Iwaki, H., Pinskerova, V., & Freeman, M. A. R. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821189 · Cited by 736
Three-dimensional kinematics of the human knee during walking
Lafortune, M. A., Cavanagh, P. R., Sommer, H. J., & Kalenak, A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90254-x · Cited by 694
Effect of skin movement on the analysis of skeletal knee joint motion during running
Reinschmidt, C., van den Bogert, A. J., Nigg, B. M., Lundberg, A., & Murphy, N. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00001-8 · Cited by 475
Meniscal movement: AN IN-VIVO STUDY USING DYNAMIC MRI
Vedi, V., Spouse, E., Williams, A., Tennant, S. J., Hunt, D. M., & Gedroyc, W. M. W. (1999) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.81b1.0810037 · Cited by 401
Self-citationTibiofemoral movement 2: the loaded and unloaded living knee studied by MRI
Hill, P. F., Vedi, V., Williams, A., Iwaki, H., Pinskerova, V., & Freeman, M. A. R. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821196 · Cited by 393
Self-citationThe envelope of passive knee joint motion
Blankevoort, L., Huiskes, R., & de Lange, A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90280-1 · Cited by 376
Maquet, P. G. J. (1984) · Springer eBooks · doi:10.1007/978-3-642-61731-7 · Cited by 301
Geometry and motion of the knee for implant and orthotic design
Kurosawa, H., Walker, P. S., Abe, S., Garg, A., & Hunter, T. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90663-3 · Cited by 292
Tibiofemoral movement 3: full flexion in the living knee studied by MRI
Nakagawa, S., Kadoya, Y., Todo, S., Kobayashi, A., Sakamoto, H., Freeman, M. A. R., & Yamano, Y. (2000) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.82b8.0821199 · Cited by 288
Cited by
The movement of the normal tibio-femoral joint
Freeman, M. A. R., & Pinskerova, V. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.006 · Cited by 532
An in vivo subject-specific 3D functional knee joint model using combined MR imaging
Chen, B., Lambrou, T., Offiah, A. C., Gondim Teixeira, P. A., Fry, M., & Todd-Pokropek, A. (2013) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-012-0801-7 · Cited by 7
Metadata
- Authors
- Johal, P., Williams, A., Wragg, P., Hunt, D., & Gedroyc, W.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2005-02
- Volume
- 38
- Issue
- 2
- Pages
- 269-276
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2095841090
- Cited by
- 360
- References
- 25
- FWCI
- 5.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using ‘interventional’ MRI. https://app.cochat.ai/papers/10.1016/j.jbiomech.2004.02.008
- The paper
- Johal, P., Williams, A., Wragg, P., Hunt, D., & Gedroyc, W. (2005). Tibio-femoral movement in the living knee. A study of weight bearing and non-weight bearing knee kinematics using ‘interventional’ MRI. Journal of Biomechanics. https://doi.org/10.1016/j.jbiomech.2004.02.008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.