A wearable system for pre-impact fall detection
Abstract
Unique features of body segment kinematics in falls and activities of daily living (ADL) are applied to make automatic detection of a fall in its descending phase, prior to impact, possible. Fall-related injuries can thus be prevented or reduced by deploying fall impact reduction systems, such as an inflatable airbag for hip protection, before the impact. In this application, the authors propose the following hypothesis: "Thigh segments normally do not exceed a certain threshold angle to the side and forward directions in ADL, whereas this abnormal behavior occurs during a fall activity". Torso and thigh wearable inertial sensors (3D accelerometer and 2D gyroscope) are used and the whole system is based on a body area network (BAN) for the comfort of the wearer during a long term application. The hypothesis was validated in an experiment with 21 young healthy volunteers performing both normal ADL and fall activities. Results show that falls could be detected with an average lead-time of 700 ms before the impact occurs, with no false alarms (100% specificity), a sensitivity of 95.2%. This is the longest lead-time achieved so far in pre-impact fall detection.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Airbag systems rely on wearable accelerometers and gyroscopes to trigger inflation when a fall is detected.
“These systems rely upon wearable accelerometers and gyroscopes to trigger the inflation of the airbag when a fall is detected.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [81]
The citation lists haven’t been fetched yet
References 25 · Cited by 241
- Authors
- Nyan, M. N., Tay, F. E. H., & Murugasu, E.
- Affiliations
- National University of Singapore (SG)
- Singapore General Hospital (SG)
- Corresponding author
- Nyan, M.N.
- ORCID
- Tay, Francis E.H.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2008-12
- Volume
- 41
- Issue
- 16
- Pages
- 3475-3481
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2104619880
- Cited by
- 241
- References
- 25
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 9 · 2023: 15 · 2022: 12 · 2021: 10 · 2020: 16 · 2019: 20 · 2018: 21 · 2017: 13 · 2016: 17 · 2015: 20 · 2014: 23 · 2013: 17 · 2012: 17
- FWCI
- 12.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- National University of Singapore (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- wearable sensors, inertial sensors, body segment kinematics, activities of daily living, body area networks
- MeSH terms
- Acceleration, Accidental Falls, Activities of Daily Living, Algorithms, Equipment Design, Humans, Telemetry, Transducers, Monitoring, Ambulatory, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review