In vitro indentation to determine the mechanical properties of epidermis
Open accessAbstract
The lack of understanding of the mechanical behavior of the human skin layers makes the development of drug delivery using microneedles or microjets a challenging task. In particular, the key mechanical properties of the epidermis composed of stratum corneum and viable epidermis should be better understood. Micro-indentation experiments were applied, using a spherical tip with a large diameter to the sample thickness ratio. The Young's moduli were derived via an analytical and a numerical method. The tests showed that the analytical method was not appropriate to assess the Young's moduli. That is why a numerical model was used to obtain the correct stiffness. When loaded perpendicularly, the stiffness of both the epidermis and stratum corneum vary between 1 and 2MPa. No significant differences in stiffness between the stratum corneum and viable epidermis were observed.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Lamination of the device over the sternum enabled wireless collection of ECG (≈2.4 GHz) at distances up to 1 m.
“Lamination of the device over the sternum enabled wireless collection of ECG (≈2.4 GHz) at distances up to 1 m.”
From Wearables in Medicine (2018) · cites this paper as [18]
The resulting assembly could be stretched (≈30% uniaxial strain) and twisted (≈75%).
“The resulting assembly could be stretched (≈30% uniaxial strain) and twisted (≈75%).”
From Wearables in Medicine (2018) · cites this paper as [18]
Commercial integrated circuits and hardware can be incorporated in flexible polymer layers.
“Commercial integrated circuits and hardware can be incorporated in flexible polymer layers.”
From Wearables in Medicine (2018) · cites this paper as [18]
Q, R, and S waveforms were identified with low signal-to-noise values as compared to the commercial hardware.
“Q, R, and S waveforms were identified with low signal‐to‐noise values as compared to the commercial hardware.18”
From Wearables in Medicine (2018) · cites this paper as [18]
The constructed system had the capability of acquisition, filtering, low-noise amplification, and frequency-modulated RF transmission of electrophysiological data.
“The constructed system had the capability of acquisition, filtering, low‐noise amplification, and frequency‐modulated RF transmission of electrophysiological data.”
From Wearables in Medicine (2018) · cites this paper as [18]
Cited by
Sorted by citations
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836 · see citing works
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569 · see citing works
- Authors
- Geerligs, M., van Breemen, L., Peters, G., Ackermans, P., Baaijens, F., & Oomens, C.
- Affiliations
- Philips (Netherlands) (NL)
- Eindhoven University of Technology (NL)
- Corresponding author
- Oomens, Cees
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2011-04
- Volume
- 44
- Issue
- 6
- Pages
- 1176-1181
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2135470014
- Cited by
- 195
- References
- 0
- Citations by year
- 2026: 9 · 2025: 11 · 2024: 10 · 2023: 16 · 2022: 18 · 2021: 12 · 2020: 12 · 2019: 18 · 2018: 9 · 2017: 14 · 2016: 17 · 2015: 13 · 2014: 10 · 2013: 10 · 2012: 10
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- green
- resolver.tudelft.nl
- Licence
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- TU/e Research Portal (publishedVersion)
- TU/e Research Portal (submittedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
- Physical Sciences › Engineering › Mechanics of Materials › Metal and Thin Film Mechanics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- epidermis, stratum corneum, skin biomechanics, indentation, Young's modulus, skin stiffness, microneedles
- MeSH terms
- Adult, Epidermis, Female, Humans, Middle Aged, Models, Biological, Pressure, Drug Delivery Systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review